Innovations in Drive Technologies High-availability, medium-voltage, variable speed drives for pumping and compression © Siemens AG 2015. 2013. All rights reserved. Common MV VSD topologies PWM 3 level LCI Multi-cell LV & MV IGBT LV & MV IGBT Thyristor IGCT • • • • • Simple, low component count 40+ years references High power density Synchronous motors Harmonic filter © Siemens AG 2015. All rights reserved. • • • • • Basic VSI platform 25 years references Induction or synchronous motors Medium Performance Standard transformer • • • • • Most Common VSI platform 20 years references Induction or synchronous motors High Performance Scalable Perfect Harmony concept – Multi-cell topology MV output waveform quality Clean output waveform allows: Use with new and old DOL motors – ideal for retrofit Use of standard cables Longer cable step-outs – longest reference ~30km! © Siemens AG 2015. All rights reserved. SINAMICS GH180 Perfect Harmony Air cooled MV drive • 150kW to 6,000 kW • 2300V • 40A 7370V output voltage 720A output current • Integrated safety earth switches • MicroHarmony: Smallest MV AC Drive on the market Perfect for offshore: 1000HP / 750 kW @ 4000V output 1.68m wide x 1.1m deep Up to 13.8kV input voltage direct! 1.68m © Siemens AG 2015. All rights reserved. SINAMICS GH150 Perfect Harmony water cooled MV Drive – Extending the proven design concepts Separate transformer gives installation flexibility + Marine certification (e.g. DNV, GL, ABS, CCS, LRS, BV classification) + Multi-level high quality output waveform + Over 3 years operation and more than 4 million hours of cell run time + Highest availability due to Cell Bypass feature and Cell redundancy + options © Siemens AG 2015. All rights reserved. Internal arc certification acc. IEC 62271-200 25kA, 500mS + GH150 - the multi-level drive that adjusts to your demands Induction motors Dry type Oil-filled IM Outdoor Retrofit motors Synchronous motors Pulse no. Line Water cooling Motor Indoor Long cables side Air cooling side M Prim. voltage © Siemens AG 2015. All rights reserved. Permanent excited motors PEM High speed >150 Hz The multi-level drive that adjusts to your line and motor side demands. Flexibility is one important key to reduce the total cost of ownership. SYN Function principle of the M2C topology P Single module X2 • 2-terminal cells without external power supply • DC-link without central energy storage • Flexible for common DC-bus applications • Flexible for front end or braking chopper • Scalable output voltage Arm X1 T11 vZ1 X2 VX21 VSM + - CSM T12 X1 L Vd L1 L2 L3 L vZ2 Module output voltages VX21 N VSM1 T12 © Siemens AG 2015. All rights reserved. T11 t Function principle of the M2C topology P Single Twin module module X2 Arm X1 T11 vZ1 X2 VX21 VVSM1 SM + - C CSM SM T12 VX21 X1 T21 L Vd L1 L L2 L3 VSM2 X1 + - CSM T22 vZ2 • 2-terminal cells without external power supply • DC-link without central energy storage • Flexible for common DC-bus applications • Flexible for front end or braking chopper • Scalable output voltage Module output voltages VX21 VSM1+ VSM2 N VSM1 VSM2 T12T,T T,T 1221 T11 1121 T 11 ,T22 tT12 ,T22 © Siemens AG 2015. All rights reserved. t Principles of operation of a Modular Multi-Level Converter (M2C) Perfect Harmony performance: • Extremely motor-friendly behavior • Near sinusoidal output voltage • Without output filter! • No motor harmonic heating • No motor/cable insulation stress • No additional bearing currents © Siemens AG 2015. All rights reserved. SINAMICS PERFECT HARMONY GH150 Cell bypass - Fault tolerance - High availability Cell cabinet – Modular plug-in cell design Cell bypass switch isolating the failed cell from the conduction path. No output speed reduction due to very fast bypass operation Increased maintainability due to modular, compact and light weight IGBT modules that are easy to replace from the front in less than 10 min Water-cooled power cell using state of the art Low Voltage IGBTs and long life self-healing air-cooled capacitors © Siemens AG 2015. All rights reserved. SINAMICS PERFECT HARMONY Long cable experience + 20 years Application: 28km start-up in 2007, 6.6kV subsea MPP, +8000V output without step-up transformer! Projects: Gannet 15km, Otter 23km, Auk 14km, Captain, Wytch Farm, Amoco Orient, Marathon Oil, Santos, Petrobras Campos Basin, India. Features: • Reduced footprint; • Direct line connection up to13.8kV • MV output; no step up transformer • IEEE 519 harmonics standard compliant • unique Cell Bypass feature Scope of Supply: • 1000+ Perfect Harmony on ESPs & MPP • 16 x 1000HP VSDs on one platform – without supply harmonic filters • Motor cable lengths from 2 km to 28km+ © Siemens AG 2015. All rights reserved. 28 km+ 1700 m SUBSEA PUMPS King GOM We are happy to answer your questions! © Siemens AG 2013. 2015. All rights reserved.