Filterautomat Type DDF page 1 / 2 Fully-automatic backwash filter with dynamic filter-drum and self-medium backwash without interruption of the filtration process during backwashing. Large solid particles are crushed in order to flush them out problem-free. Backwash speed in the filter element up to 10 m/s. medium : ................................................... temperature : °F ................................................... main connection flanges according to ANSI : inch ................................................... backwash by : self-medium circulatory capacity : gpm filter element, type : filter fineness : special slotted sieve (AISI 317L) special wire-cloth screen (AISI 304 / 316) micron ................................................... working pressure design pressure pressure loss with clean filter approx. : : : psi psi psi filter drive : three-phase worm gear motor with surface cooling electric tension : V/HZ ……………………………………. weight empty approx. : lbs .................................................... weight filled with water approx. : lbs .................................................... filter housing : filter drum, external and internal basket : grey-cast with internal painting of synthetic material of several components grey-cast coated with epoxi-powder filter insert : stainless steel AISI 317L / 316 drive shaft with wearing bushing : stainless steel AISI 316Ti external painting : epoxy resin min. 150 micron / RAL 6018 dimensions acc. to drawing : no. ................................................... .................................................... ……………………………………. ……………………………………. materials ................................................... AUTOMATIC CONTROL for Filterautomat Type DDF page 2 / 2 for filter backwash in intervals — — working time-dependent with overriding differential pressure - differential pressure - adjustable 0 - 1,6 bar - time-flushing interval - adjustable continuously - 10 hours - flushing time - adjustable continuously - 10 hours with potential free contact: filter in operation with potential free contact: filter in flushing process (backwash valve open) with potential free contact for collective fault indication in the central control station After response of the collective fault indication the following faults will be indicated at the DDS-control cabinet: either faults in the filter operation either faults at the electrical drive or differential pressure too high starting of the flushing process from the control room release of the flushing process from the control room consisting of: butterfly valve, differential pressure gauge, electronic control unit, knitted pressure wiring and assembly parts as well as backflushing lines, pre-mounted at the filter butterfly valve product contacting parts : : inch .................................................... stainless steel with electrical drive voltage : V/Hz ……………………………………. nominal output : Watt ……………………………………. with integrated overload protection, limit switches, emergency hand-wheel and position indication at site including limiting loss of flushing water by mechanical special feature dependent on the working pressure differential pressure gauging, consisting of differential pressure manometer static pressure measuring range with 2 adjustable micro-switches with integrated inlet-pressure indicator incl. cocks + screwings : : psi psi ……………………………………. ……………………………………. electronic control unit housing protective system dimensions: height x width x depth working voltage control voltage type of attachment steel plate Nema 4 inch 15x24x8 V/Hz .……………………………………. 24 V DC wall-attachment at site The flushing water quantity of the Filterautomat is : gpm .................................................... gal .................................................... flushing water quantity per each flushing process – duration 20 s : higher pressure stages and other materials deliverable on demand manufacturer : DANGO & DIENENTHAL Inc. Alliance, Ohio 44601, 330-829-7978