Blitz Custom Homes – Montgomery, Texas

advertisement

Blitz Custom Homes – Montgomery, Texas

Standard Specifications

EXTERIOR

Utilities Entergy, Midsouth, Centerpoint, Reliant– Electric

Centerpoint, Unigas– Gas

Hays, Midsouth, Quadvest, Far Hills– Water & Sewer

Consolidated Com. – Phone

Plan Location

Orientation

Excavation

Foundation

Cebridge – Cable

Blitz Custom Homes reserves the right to determine the location and orientation due to lot topography, utility locations, drainage plans, storm inlets, and trees. It may be necessary to drop garage floors, add steps at entries, rear patios, or lead walks.

Removal of surface vegetation may be required per engineer. Native treecanopiesshould not extend over the foundation, as a root structure is not allowed to extend under the foundation. A pre construction homesite inspection is preformed prior to tree removal.

Plans engineered per lot specs with a post tension cable design. Concrete to have a minimum compressive strength of 3,000

PSI at 28 days. Water proofing vapor barrier of .006polyethylene. A soil report is required for an engineered foundation with an inspection preformed prior to placement of concrete.

Driveway

Leadwalks

Front Porch

Rear Patio

Frame Walls

Broom finish concrete driveway with minimum compressive strength of 3,000 PSI at 28 days. Approach is constructedto current HOA requirements.

Concrete broom finish standard of 3’ wide.

Broom finished concrete sloped to drain away from home.

Per plan – broom finish.

Wolmanizedtreated bottom plates on concrete. 12” moist stop brick ledge vapor barrier. 16” OC 2x4 stud grade material on all loadbearing walls. Ram set shots per code requirements. Double top plate on all loadbearing members. Headers per plan. 1 by 4 let-inembracing added per plan. Framing inspection preformed by certified inspector.

Masonry

Soffit, Fascia and

Trim

BrickACMEper plan. Tool concave joints. Brick expansion joints every 25’. Weep holes every 3 rd brick at the bottom or as necessary. Brick cleaned per manufacturers recommendations. Masonrymortarin natural gray.

Fascia is a 2x4 band around home to attach a hardiplank fiber cementfascia. Soffit ishardiemasonite per plan with a brickfreeze as needed with a continuous soffit venting. Trim is 1x2, 1x4, 1x6 or 1x8 primedhardieper plan. House is wrapped with Tyvek moisture

barrier. Sidding isan8” textured Hardie product with a 30-year limited non-prorated manufacture’s warranty.

Exterior Paint Sherman Williams100% acrylic paint. All paintable surfaces are prime and caulked prior to painting. One color is provided for sidding and additional color is provided for trim.

Exterior Door Mahogany wood stained front doorwith aluminum weather-strip and

Front sill cover.

Garage Access 3’0” by6’8”fire rated solid core door with adjustable threshold finished in paint.

Patio Door

Garage Door

Roofing

Per plan.

Steel 24 gauge or better. Raised panel. Wood grain texture with compression bottom weather strip. Painted on exterior only.

30 year dimensional Elk II class C fiberglass shingle.Sablewoodis standardcolor. #15 felt underlayment with #90 felt valley flashing. 20 gauge step flashing at brick roof and wall intersections. Single flashing around perimeterof roof. Radiant barrier roof deckingused on entire roof surface with ridge vents provided to allow roof venting.

Landscaping Per HOA requirements.

STRUCTURAL

Wall Framing Loadbearing walls are 14” on center and non loadbearing are 16” on center.

Ceiling Framing

S.Y.P. 24” on center with grade specifications according to plan.

Rafter Framing #3 grade S.Y.P. placed per plan.

Fireplace Optional fireplace per plan

Insulation Exterior FiberglassR-15 insulated on exterior walls. R-19 paperless batts used

Walls on sloped ceilings. R-38 blown insulation used in ceilings. Down sill seal used between slab and exterior plate to minimize air and water filtration from under walls. Polyseal all exterior walls and plates.

Flat Ceiling

Areas

Blown insulationon flat areas. R-19 on slopped ceiling areas.

INTERIOR

Wallboard

Texture

American made ½” onwalls and ceilings. ½” durarock moisture resistant board usedontub and shower wallssealed with an anti-fracture material. All sheetrock hung with nails on the perimeter then screwed in the field area. Rounded sheetrock corners are provided throughout home.

All walls medium splattered and drag texture. No texture in garage.

Standard float tape and skim.

Interior Paint Sherman Williamslatex flatfinisheswith enamel trim. Colors to be selected by homeowner.

Interior Trim Double crownmolding (CM-22)in entry, dining, and formal areas. Raisedsixpanel doors used throughout homewith painted hinges. Closets have wood shelves and rod supports for

Cabinets

Countertops –

Kitchen

MasterBath clothing. Baseboard(BB1)and moldinglacqueredand pre primed for superior finish.

Custombuilt per specifications. 42” upper cabinets used per planstained finish topped with crown molding.

Granite countertops provided in the kitchen with a tiled backsplash. Moen pullout sprayer faucet. Stainless steelunder mountsink included

Cultured marble with square edge per plan. Bowl is a seashell design.Widespread Moen faucets.

Pedestal sink. PowderBath

Hall Baths

Plumbing

Cultured marble with square edge per plan. Bowl is a seashell design. Five foot tub is standard.

All pex water supply lines, ¾” minimum service line. 50-gallon natural gas water heater. 1/3 horsepower disposal provided. 2 hose bibs per plan.Ice maker connection provided for refrigerator. Man-O-

Bloc flowguard corrosion resistant panel provided. Plumbing grounds, plumbing rough inspections preformed by certified inspector. All bronze Moen fixtures throughout home come with a lifetime manufacture’s warranty.

Master Bath Fiberglassoversized garden tub provided with tile surround and tub skirtwith Moen faucets. Medicinecabinet located alongsidepolished edge mirror. Elongated commode included in master bath.

Master Shower Fiberglass showerbase with clear glass and bronzetrim per plan. Shower valve is bronzeMoen.

Hall Baths

Kitchen

Faucets Moen.

Sink is stainless steel with Moen faucet.

Electrical Master bedroom, secondary bedrooms, are blocked and pre-wired for ceiling fans. Ceiling fans are included in master and family. All rooms shall include oneTV (RG6)andphone (Cat5)outlet. 220 amp breaker service provided with labeled circuit breakers. Smoke detectors required per code throughout housewith battery back-ups. House is pre-wired for security package. Outlet in garage ceiling for garage door opener. GFCI protected outlets located on front and back porch with the reset located in garage. Electrical inspection preformed by certified inspector.

Lighting Fixtures Energy star recessed cans throughout home. Bronze lighting fixtures provided per plan.

Hardware Better Homes bronzehardware provided throughout house. Privacy locks provided on master bedroom and all baths.

Flooring

Appliances

Windows

Per plan. Tile standard in entry, kitchen/breakfast, utility, and all bathrooms. Carpet is a 25 ounce product with a ½” pad.

Whirlpoolappliances included in kitchen with a gascook top.

Low E double pained high energy efficient. Divided lite windows provided on front elevation. All operable windows include

HVAC screens. Choice of obscured or clear glass in master bath. Water resistant barrier provided at all window sills.

Tonnage and units based per planwith zone controlwith a minimum

SEER rating of 14. Natural gas heating system provided where applicable.Vent fans installed per code. Digital thermostats provided with a carrier HVAC condenser. HVAC inspection preformed by certified inspector.