Life Flight Building Specifications The successful bidder must

advertisement
Life Flight Building Specifications
The successful bidder must propose a pre-engineered steel building meeting the specifications
of the attached drawings. The drawings are for elevation and dimension purposes.
Interior Walls/ OFFICE- 2x4 DFL @ 16”OC
Sound Batts as Spec'd by Owners Inside office to be 1/2” Drywall on Exposed Surfaces
Shop Side of Office Walls to be 7/16" OSB paint to match balance of
Insulation RequirementsAttic- Minimum R38
Exterior Conditioned Walls- R21
Interior Walls- Owner Specified
Windows- Vinyl Frames /Low E Glazing
Electrical- 400 Amp 220 Single Phase Preferred
Lighting to be T-5 or greater
Heating- Radiant Gas Heat Preferred
All Measures Shown are Framing Measures unless otherwise noted.
Aviation Bi-Fold Doors- 70'-0" Width x 18'-0" Height w/electric Operation
Must have minimum 16'0" Vertical clearance for Aircraft
Approved manufacturers include Hi-Fold Door Corp (www.hi-fold.com)
or Schweiss Aviation Bi-fold (www.schweissdoors.com)
(Bidder to submit Manufacturers Specifications for review)
Walk Doors- Minimum 24 Gauge Insulated /
Exterior Jamb System w/ Weather stripping
Single bore Prep with 2 3/4” back-set / Hydraulic Closure on
Exterior Door Systems
Exterior Metal Veneer (Roof & Walls)- 29 Gauge minimum /
Painted Finish
Interior Ceiling finish- 1” Thick Thermal Sheeting rated for exposure (R 7.2 typical) with
seams and fasteners taped/finished for presentation and function.
Flood lights in stalled (3) on West side of building and (2) on front of building over entry door and west side of hanger
door.
All Workmanship & Materials to 'Meet or Exceed' Current Codes & Requirements