Life Flight Building Specifications The successful bidder must propose a pre-engineered steel building meeting the specifications of the attached drawings. The drawings are for elevation and dimension purposes. Interior Walls/ OFFICE- 2x4 DFL @ 16”OC Sound Batts as Spec'd by Owners Inside office to be 1/2” Drywall on Exposed Surfaces Shop Side of Office Walls to be 7/16" OSB paint to match balance of Insulation RequirementsAttic- Minimum R38 Exterior Conditioned Walls- R21 Interior Walls- Owner Specified Windows- Vinyl Frames /Low E Glazing Electrical- 400 Amp 220 Single Phase Preferred Lighting to be T-5 or greater Heating- Radiant Gas Heat Preferred All Measures Shown are Framing Measures unless otherwise noted. Aviation Bi-Fold Doors- 70'-0" Width x 18'-0" Height w/electric Operation Must have minimum 16'0" Vertical clearance for Aircraft Approved manufacturers include Hi-Fold Door Corp (www.hi-fold.com) or Schweiss Aviation Bi-fold (www.schweissdoors.com) (Bidder to submit Manufacturers Specifications for review) Walk Doors- Minimum 24 Gauge Insulated / Exterior Jamb System w/ Weather stripping Single bore Prep with 2 3/4” back-set / Hydraulic Closure on Exterior Door Systems Exterior Metal Veneer (Roof & Walls)- 29 Gauge minimum / Painted Finish Interior Ceiling finish- 1” Thick Thermal Sheeting rated for exposure (R 7.2 typical) with seams and fasteners taped/finished for presentation and function. Flood lights in stalled (3) on West side of building and (2) on front of building over entry door and west side of hanger door. All Workmanship & Materials to 'Meet or Exceed' Current Codes & Requirements