C ATA L O G # : TYPE: DESCRIPTION Specification grade 32 Watt triple tube compact fluorescent fixture. For use with narrow joist spacing. Insulation must be kept 3" from fixture sides and top of fixture. The 50° cutoff to lamp and lamp image provides a glare free, smooth, medium beam distribution. Triple tube lamps provide excellent color, long life, and low radiant heat. Dimming and emergency ballast options are available. Lamp module and optical element can be changed after installation to provide a variety of lamp sources and distributions. e.g. into a PAR36 Adjustable. 5 1/4" D G D C A H F B PN5 M42T E5T 5 1/4" [134mm] 6 1/4" [159mm] 6 3/4" [172mm] S P E C I F I C AT I O N F E AT U R E S A ...Reflector F . . . E l e c t ri c a l .040 thick aluminum spun parabolic reflector. Reflector is available in iridescent free Clear, Gold, Haze, Warm Haze Alzak®, or painted gloss white Alzak® finish. Special cone colors listed below. Keyed quick connect provides easy lamp module installation. B ...Flange Self flange reflector or die-cast flange with either matte white or clear coat finish. Die-cast flanges are easily removed for field painting. Elements are keyed for proper insertion. G ...Junction Box 18 cubic inches, listed for 4#12 AWG or 6#14 AWG 90° C additional feed through conductors, has five 1/2 inch pryouts. Positive torsion springs pull flange tight to ceiling. Mechanical light trap eliminates spill light at edge of flange or reflector. D ...S o cke t I ...Frame/Housing 4 pin G24q3 base for 32W PLT, TBX and TTT lamps. Fatigue free stainless steel spring ensures positive lamp retention. Fixed socket height ensures consistent lamp position. Hot dipped galvanized 20 gauge steel frame with built in 1/2 inch plaster lip. Gunsights allow for consistent alignment. One piece 20 gauge steel housing for seamless construction is painted matte black for a visually dark interior. E ...Electronic Ballast Thermally protected, current controlled electronic ballast produces full light output and rated lamp life. For 32W and 26W triple tube lamps. Provides flicker-free and noise-free operation and starting with 120 volt input. Meets stringent Class B requirements, FCC part 18, for non-commercial applications. M32T Lutron for use with 32W lamp only. 5" DOWNLIGHT H ...Bar Hangers No Flex® bar hangers with positive locking, for use with wood, engineered wood and steel frame joists spaced up to 24" O.C. ship with platform. For use in T-bar ceilings order accessory MBCLP clips. Nailess barb and locator lip provide consistent installation height. C ...Attachment 32 26W TRIPLE Compact Fluorescent Codes Thermally protected, IP labeled, Unit is airtight and exchanges less than 2.0 CFM with the plenum at a pressure of 75 pascals. Insulation must be kept three inches away from fixture sides and none on top as to entrap heat. 8 1/2" [216mm] 16 1/2" [419mm] 4 15/16" [126mm] 8 1/2" [216mm] Ceiling Cutout 6 1/4" (159mm) E N E R G Y D ATA M42T Input Power: 120V = 36W Input Current (Max.): 120V = .306 Power Factor: 120V = > .98 T.H.D.: 120V = < 10% M32TLUTRON Labels UL and cUL listed, standard damp label, IBEW union made. O R D E R I N G I N F O R M AT I O N Input Power: 120V = 36W Input Current (Max.): 120V = .33A Power Factor: 120V = > .95 T.H.D.: 120V = < 20% Complete unit consists of a platform, module and element P l a t f o rm Lamp Module PN5 M42T PN5= 5" Airtight Non ICHousing M42T=32/26W Compact Fluorescent Ballast M32TLUTRON= 32W Tu Wire Dimmable Ballast Optical Element E5T= 5" Downlight Reflector Finish Standard C=Clear H=Haze G=Gold WMH=Warm Haze W=Gloss White MW=Matte White Custom K=Cognac KH=Cognac Haze CC=Chocolate COOPER LIGHTING Custom cont. CCH=Chocolate Haze BU=Blush BUH=Blush Haze GP=Graphite GPH=Graphite Haze PN=Pine PNH=Pine Haze SK=Sky SKH=Sky Haze Flange A c c e s s o ri e s Blank=White die-cast SF=Self Flange RAW=Natura l Die-cast SFWF=Self Flange Painted White MBCLP=40 Push On T Bar Clips (for 10 Units) PLE5=Plaster Lip Extension for Max 2" Thick Ceiling FMC5=Flush Mount Collar For additional options please consult factory. ADI030688 Unit Number: P N 5 - M 3 2 T- E 5 T _ P H OTO M E T R I C S PN5-M32T-E5TC Candelas Test No. H36087 Lamp: Lumens: 32W PLT 2400 Vertical Angle 90 85 75 65 55 45 35 25 15 5 0 Cutoff: Spacing: Efficiency: Unit LPW: 50° 1.1 33.7% 22.4 D i s t ri b u t i o n Luminance CD 0 0 0 0 0 134 365 522 605 586 552 Cone of Light cd/m2 0 Degree 85˚ 75˚ 0 65˚ 0 55˚ 0 45˚ 13584 Distance to Illuminated Plane Initial Nadir Footcandles Beam Diameter 29 19 14 9 6 4 4'6" 5'6" 6'6" 8'0" 10'0" 12'0" 5'0" 6'6" 7'6" 9'6" 11'6" 14'0" 0° Zonal Lumen Summary Coefficient of Utilization Zone 0-30 0-40 0-60 0-90 90-180 Lumens 466 692 803 810 0 %Lamp 19.4 28.8 33.4 33.7 0.0 %Luminaire 57.6 85.5 99.1 100.0 0.0 0-180 810 33.7 100.0 PN5-M32T-E5TC Candelas Test No. H36107 Lamp: Lumens: 26W PLT 1800 Vertical Angle 90 85 75 65 55 45 35 25 15 5 0 Cutoff: Spacing: Efficiency: Unit LPW: 50° 1.1 38.7% 23.2 Ceiling Reflectance Wall Reflectance Room Cavity Ratio 0 1 2 3 4 5 6 7 8 9 10 70 50 30 10 50 70% 10 50 10 50 10 0% 0 40 38 37 35 33 31 30 28 27 25 24 40 37 35 33 31 29 27 25 23 22 20 40 37 34 31 29 27 25 23 21 20 18 40 36 33 30 28 25 24 22 20 18 17 39 37 34 32 30 28 27 25 23 22 20 39 35 32 30 27 25 24 22 20 18 17 37 35 33 31 30 28 26 25 23 21 20 37 34 32 29 27 25 23 22 20 18 17 36 34 32 31 29 27 26 24 23 21 20 36 33 31 29 27 25 23 21 20 18 17 34 32 30 28 26 24 23 21 19 18 16 80% D i s t ri b u t i o n Luminance CD 0 0 0 0 0 103 305 460 566 572 540 30% Cone of Light cd/m2 0 Degree 85˚ 50% 75˚ 0 65˚ 0 55˚ 123 45˚ 10406 Distance to Illuminated Plane Initial Nadir Footcandles 4'6" 5'6" 6'6" 8'0" 10'0" 12'0" Beam Diameter 5'0" 6'0" 7'0" 9'0" 11'0" 13'0" 27 18 13 8 5 4 0° Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens 426 616 698 701 0 701 %Lamp 23.7 34.2 38.8 38.9 0.0 38.9 Coefficient of Utilization %Luminaire 60.8 87.9 99.6 100.0 0.0 100.0 Ceiling Reflectance Wall Reflectance Room Cavity Ratio 0 1 2 3 4 5 6 7 8 9 10 70 50 80% 30 10 50 70% 10 50 50% 10 50 30% 10 0% 0 46 44 425 41 39 37 35 33 31 30 28 46 43 41 38 36 34 32 30 28 26 24 46 42 39 36 34 32 30 28 26 24 22 46 42 38 35 33 30 28 26 24 22 21 45 43 40 38 36 33 32 30 28 26 24 45 41 38 35 32 30 28 26 24 22 21 43 41 39 37 35 33 31 29 27 25 24 43 40 37 34 32 30 28 26 24 22 21 41 40 38 36 34 32 30 29 27 25 24 41 39 36 34 32 29 28 26 24 22 20 39 37 35 33 31 29 27 25 23 21 20 Notes and Formulas: Luminance: To convert cd/m2 to footlamberts, multiply by 0.2919 Cone of Light: • Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. • Footcandle values are initial. Apply appropriate light loss factors where necessary. See page 64-65 of catalog. CU Notes/Formulas: • maintained illuminance=lamp lumens x CU x light loss factors room area • total number of luminaires=total room area x maintained illuminance lamp lumens x CU x light loss factors • CU data based on 20% effective floor cavity reflectance.