Specification grade 32 Watt triple tube compact flu-

advertisement
C AT A L O G # :
TYPE:
DESCRIPTION
Specification grade 32 Watt triple tube compact fluorescent fixture rated for direct contact with insulation. The 50° cutoff to lamp and lamp image provides a glare free, smooth, medium beam
distribution. Triple tube lamps provide excellent
color, long life, and low radiant heat. Dimming and
emergency ballast options are available. Lamp
module and optical element can be changed after
installation to provide a variety of lamp sources
and distributions. e.g. into a PAR36 adjustable
5 1/4"
G
D
P5
M32T
E5T
F
H
E
A
I
C
32W TRIPLE
5 1/4"
[134mm]
B
Compact Fluorescent
6 1/4"
[159mm]
6 3/4"
[172mm]
S P E C I F I C AT I O N F E AT U R E S
5" DOWNLIGHT
A ...Reflector
F ...Electrical
.040 thick aluminum spun parabolic reflector in
iridescence-free Clear, Gold, Haze, Warm Haze
Alzak® or painted Gloss White finish. Special cone
colors listed below
Keyed quick connect provides easy lamp module
installation.
B ...Flange
Self flange reflector or die-cast flange with either
matte white or clear coat finish. Die-cast flanges
are easily removed for field painting. Elements
are keyed for proper insertion.
C ...Attachment
Positive torsion springs pull flange tight to
ceiling. Mechanical light trap eliminates spill light
at edge of flange or reflector.
D ...Socket
4 pin G24q3 base for 32W PLT, TBX and TTT
lamps. Fatigue free stainless steel spring ensures
positive lamp retention. Fixed socket height
ensures consistent lamp position.
E ...Electronic Ballast
Thermally protected, current controlled electronic
ballast produces full light output and rated lamp
life. For 32W and 26W triple tube lamps. Provides
flicker-free and noise-free operation and starting
with 120 or 277 volt input. Meets stringent Class B
requirements, FCC part 18, for non-commercial
applications. M32T Lutron for use with 32W lamp
only.
G ...Frame/Housing
Hot dipped galvanized 20 gauge steel frame
with built in 1/2 inch plaster lip. Gunsights allow
for consistent alignment. Aluminum .032 thick
housing allows for heat dissipation and reduces
weight.
9"
[229mm]
7 7/8"
15 3/4" [201mm]
[401mm]
10"
[254mm]
Ceiling Cutout
6 1/4" (159mm)
H ...Junction Box
18 cubic inches, listed for 4#12 AWG or 6#14 AWG
90° C additional feed through conductors, has six
1/2 inch pryouts.
I ...Bar Hangers
No Flex® bar hangers with positive locking, for
use with wood, engineered wood and steel frame
joists spaced up to 24" O.C. ship with platform for
use in T-bar ceilings order accessory MBCLP clips.
Nailess barb and locator lip provide consistent
installation height.
Codes
Thermally protected, IP labeled, for use in direct
contact with insulation. Meets Washington State
Air tight requirements, 1995 CABO Model Energy
Code.
Labels
UL and cUL listed, standard damp label,
IBEW union made.
O R D E R I N G I N F O R M AT I O N
E N E R G Y D AT A
M32T
Input Power:
120V = 36W
Input Current (Max.):
120V = .306A
Power Factor:
120V = > .98
T.H.D.:
120V = < 10%
M32T Lutron
Input Power:
120V = 36W
Input Current (Max.):
120V = .33A
Power Factor:
120V = > .95
T.H.D.:
120V = < 20%
Complete unit consists of a platform, module and element
Platform
Lamp
Module
P5
M32T
P5=5"
Airtight IC
Rated
Housing
M32T=32/26W
Compact
Fluorescent
Ballast
M32TLutron=
32W Tu Wire
Dimmable
Ballast
COOPER LIGHTING
Optical
Element
E5T= 5"
Downlight
Reflector
Finish
Standard
C=Clear
H=Haze
G=Gold
WMH=Warm Haze
W=Gloss White
MW=Matte White
Custom
K=Cognac
KH=Cognac Haze
CC=Chocolate
Flange
Accessories
Custom Cont.
Blank=White
MBCLP=40 Push
die-cast
On T Bar Clips
CCH=Chocolate
(for 10 Units)
Haze
SF=Self
Flange
PLE5=Plaster
BU=Blush
Lip Extension
BUH=Blush Haze
RAW=Natural
for Max 2" Thick
Die-cast
GP=Graphite
Ceiling
SFWF=Self
GPH=Graphite
FMC5= Flush
Flange
Haze
Mount Collar
Painted
PN=Pine
White
PNH=Pine Haze
For Emergency Option order P532TEMER and
SK=Sky
E5T_ see catalog for ordering information. For
SKH=Sky Haze additional options please consult factory.
ADI030702
Unit Number: P 5 - M 3 2 T- E 5 T _
PHOTOMETRICS
P5-M32T-E5TC
Candelas
Test No.
H36087
Lamp:
Lumens:
32W PLT
2400
Vertical
Angle
90
85
75
65
55
45
35
25
15
5
0
Cutoff:
Spacing:
Efficiency:
Unit LPW:
50°
1.1
33.7%
22.4
Distribution
Luminance
CD
0
0
0
0
0
134
365
522
605
586
552
Cone of Light
cd/m2
0
Degree
85˚
75˚
0
65˚
0
55˚
0
45˚
13584
Distance to
Illuminated Plane
Initial Nadir
Footcandles
Beam
Diameter
29
19
14
9
6
0
4'6"
5'6"
6'6"
8'0"
10'0"
12'0"
5'0"
6'6"
7'6"
9'6"
11'6"
14'0"
0°
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Lumens
466
692
803
810
0
810
%Lamp
19.4
28.8
33.4
33.7
0.0
33.7
Coefficient of Utilization
%Luminaire
57.6
85.5
99.1
100.0
0.0
100.0
P5-M32T-E5TC
Candelas
Test No.
H36107
Lamp:
Lumens:
26W PLT
1800
Vertical
Angle
90
85
75
65
55
45
35
25
15
5
0
Cutoff:
Spacing:
Efficiency:
Unit LPW:
50°
1.1
38.7%
23.2
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
70
50
80%
30
10
50
10
50
10
50
10
0%
0
40
38
37
35
33
40
37
35
33
31
40
37
34
31
29
40
36
33
30
28
39
37
34
32
30
39
35
32
30
27
37
35
33
31
30
37
34
32
29
27
36
34
32
31
29
36
33
31
29
27
34
32
30
28
26
31
30
28
27
25
24
29
27
25
23
22
20
27
25
23
21
20
18
25
24
22
20
18
17
28
27
25
23
22
20
25
24
22
20
18
17
28
26
25
23
21
20
25
23
22
20
18
17
27
26
24
23
21
20
25
23
21
20
18
17
24
23
21
19
18
16
Distribution
70%
Luminance
CD
0
0
0
0
0
103
305
460
566
572
540
30%
Cone of Light
cd/m2
0
Degree
85˚
50%
75˚
0
65˚
0
55˚
123
45˚
10406
Distance to
Illuminated Plane
Initial Nadir
Footcandles
Beam
Diameter
27
18
13
8
5
4
4'6"
5'6"
6'6"
8'0"
10'0"
12'0"
5'0"
6'0"
7'0"
9'0"
11'0"
13'0"
0°
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Lumens
426
616
698
701
0
701
%Lamp
23.7
34.2
38.8
38.9
0.0
38.9
Coefficient of Utilization
%Luminaire
60.8
87.9
99.6
100.0
0.0
100.0
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
70
50
80%
30
10
50
70%
10
50
50%
10
50
30%
10
0%
0
46
44
425
41
39
37
35
33
31
30
28
46
43
41
38
36
34
32
30
28
26
24
46
42
39
36
34
32
30
28
26
24
22
46
42
38
35
33
30
28
26
24
22
21
45
43
40
38
36
33
32
30
28
26
24
45
41
38
35
32
30
28
26
24
22
21
43
41
39
37
35
33
31
29
27
25
24
43
40
37
34
32
30
28
26
24
22
21
41
40
38
36
34
32
30
29
27
25
24
41
39
36
34
32
29
28
26
24
22
20
39
37
35
33
31
29
27
25
23
21
20
Notes and Formulas:
Luminance: To convert cd/m2 to footlamberts, multiply by 0.2919
Cone of Light:
• Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
• Footcandle values are initial. Apply appropriate light loss factors where necessary.
See page 64-65 of catalog.
CU Notes/Formulas:
• maintained illuminance=lamp lumens x CU x light loss factors
room area
• total number of luminaires=total room area x maintained illuminance
lamp lumens x CU x light loss factors
• CU data based on 20% effective floor cavity reflectance.
Note: Specifications and Dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 ADI030702
Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049
Download