DESCRIPTION
Specification grade 32 Watt triple tube compact fluorescent
fixture rated for direct contact with insulation, for use in wet
locations. The AIRTITE™ housing prevents airflow between
attic and living areas. Regressed frosted lens provides a low
brightness aperture and a smooth illumination pattern.
®
Type
Catalog #
Project
Date
Comments
Prepared By
S P E C I F I C AT I O N F E AT U R E S
Reflector/Lens
High purity 0.040° thick machine-spun
aluminum specular clear upper and
spun parabolic lower reflector in a
broad range of finishes.
Flange
Self-flanged reflector or die-cast
flange with either matte white or clear
coat finish. Die-cast flanges are easily
removed for field painting. Elements
are keyed for proper insertion. Gasket
is a closed cell foam.
Lens
.125 thick frosted lens obscures lamp
and is retained during relamping.
Attachment
Positive torsion springs pull flange
tight to ceiling. Mechanical light trap
eliminates spill light at edge of flange
or reflector.
Lamp Socket
4 pin Gx24 (q-3) + (q-4) base for
26/32W PLT, TBX and TTT lamps.
Fatigue free stainless steel spring
ensures positive lamp retention. Fixed
socket height ensures consistent lamp
position.
Electronic Ballast
Thermally protected, current
controlled rapid start 120VAC Input
ballast produces full light output and
rated lamp life. Meets stringent FCC
requirements for EMI/RFI consumer
limits.
Lamp
Generic Compact Fluorescent Lamp
Designations (by others)
• CFTR26W/GX24q 2700K
• CFTR26W/GX24q 3000K
• CFTR32W/GX24q 2700K
• CFTR32W/GX24q 3000K
Frame/Housing
Hot dipped galvanized 20 gauge steel
frame with built in 1/2 inch plaster lip.
Aluminum .032 thick housing allows
for heat dissipation and reduces
weight.
Junction Box
18 cubic inches, listed for 4 #12
AWG or 6 #14 AWG 90° C additional
feed through conductors, has
(6) 1/2 inch pryouts.
Bar Hangers
No Flex® bar hangers with positive
locking, for use with joists spaced
up to 24" O.C. ship with platform.
Integralnail and locator lip provide
consistent installation height.
Codes
Thermally protected, IP labeled for
use in direct contact with insulation.
Compliance
• State of California Title 24
• Washington State Energy Code
• New York State Energy Conservation
Construction Code
• International Energy Conservation Code
P532ICAT
E5SR
26/32W TTT
Compact Fluorescent
5-Inch Regressed Lens Showerlight
Labels
UL and cUL listed, standard wet label,
IBEW union made.
9"
[229mm]
15-3/4"
[401mm]
7-7/8"
[201mm]
10"
[254mm]
Ceiling Cutout 6-1/6" [159mm]
ENERGY DATA
EMI/RFI Emissions FCC Part 18 Consumer Limits
Input Frequency 50/60 Hz
Power Factor > 0.98
THD < 10%
Input Voltage 120V
26W
32W
Input Power
29W
Input Current
.24A
Input Power
36W
Input Current
0.306
5-1/4"
[134mm]
6-1/4"
[159mm]
6-3/4"
[172mm]
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADI041416
2012-03-26
IRIS
®
O R D E R I N G I N F O R M AT I O N : C o m p l e t e l u m i n a i r e c o n s i s t s o f a h o u s i n g p l a t f o r m a n d o p t i c a l e l e m e n t .
Example: P532ICAT + E5SR
P l a t fo rm
Optical Element
P532ICAT
P532ICAT = 5" Airtight IC rated
housing with electronic ballast
120V input
Finish
Flange
A c c e s s o ri e s
[Blank] = Matte White Die-cast Flange
POL = Polished Aluminum Die-cast Flange
RAW = Natural Die-cast Flange
SAL = Satin Aluminum Die-cast Flange
SF = Self-flange
SFWF = Self-flange Painted White
PLE5 = Plaster Lip Extension
for Max 2" Thick Ceiling
E5SR
E5SR = 5" Regressed
Lens Showerlight
Alzak® Finishes
B = Black
C = Clear
CC = Chocolate
CCH = Chocolate Haze
G = Gold
GP = Graphite
GPH = Graphite Haze
H = Clear Haze
WMH = Warm Haze
K = Cognac
KH = Cognac Haze
WH = Wheat
WHH = Wheat Haze
Painted Finishes
MB = Matte Black
MW = Matte White
W = Gloss White
P H OTO M E T R I C S P 5 3 2 I C AT E 5 S R
Photometric Results
Luminance
Candlepower Distribution
Efficiency = 32.4%
Downlight
Cone of Light
Degree
Candelas
cd/m2
Test No. H36117
Platform = P532ICAT
Element = E5SRC
Lumens = 1800
Lamp = 26W PLT
26TTT
85º
0
75º
1410
65º
6266
55º
10183
45º
14384
D
FC
Beam
Diameter
4'6"
15
5'0"
5'6"
10
6'6"
6'6"
7
7'6"
8'0"
5
9'6"
10'0"
3
11'6"
12'0"
2
14'0"
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
0
5
37
82
142
202
256
294
309
311
0˚
Zonal Lumens Summary
Zone
Coefficients of Utilization
Ceiling
Reflectance
Wall
Reflectance
RCR
Lumens % Lamp % Luminaire
0-30
230
12.8
39.5
0-40
356
19.8
61.1
0-60
539
30.0
92.6
0-90
582
32.4
100.0
90-180
0
0.0
0.0
0-180
582
32.4
100.0
0
1
2
3
4
5
6
7
8
9
10
80%
70%
50%
30%
0%
70
50
30
10
50
10
50
10
50
10
0
38
36
34
32
30
28
26
24
22
21
19
38
35
32
29
27
24
22
20
18
17
16
38
34
31
27
25
22
20
18
16
15
13
38
33
29
26
23
20
18
16
14
13
12
38
34
32
32
26
24
22
20
18
17
15
38
33
29
29
23
20
18
16
14
13
12
36
33
30
30
26
23
21
19
18
16
15
36
32
28
28
22
20
18
16
14
13
12
34
32
29
29
25
23
21
19
17
16
15
34
31
28
28
22
20
18
16
14
13
12
32
29
26
26
21
19
17
15
14
12
11
N OT E S A N D F O R M U L AS P 5 3 2 I C AT E 5 S R
Luminance:
• To convert cd/m2 to footlamberts, multiply by 0.2919
Cone of Light:
• Beam diameter is at 50% of maximum footcandles, rounded to the nearest half-foot.
• Footcandle values are initial. Apply appropriate light loss factors where neccessary.
CU Notes/Formulas:
• Maintained illuminance = lamp lumens x CU x light loss factors
room area
• Total number of luminairies = total room area x maintained illuminance
lamp lumens x CU x light loss factors
• CU data based on 20% effective floor cavity reflectance.
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.