C AT A L O G # : TYPE: DESCRIPTION Specification grade A lamp fixture for use with narrow joist spacing. Insulation must be kept 3" from fixture sides and top of fixture. The 50° cutoff to lamp and lamp image provides a glare-free, smooth, medium beam distribution. Lamp module and optical element can be changed after installation to provide a variety of lamp sources and distributions. e.g. into a PAR36 Adjustable. 5 1/4" D PN5 M120 E5P30 H F A E C 75WPAR30L 75W PAR30 100W R30 5 1/4" [134mm] 6 1/4" [159mm] 6 3/4" [172mm] B 85W BR30 5" DOWNLIGHT S P E C I F I C AT I O N F E AT U R E S A ...Reflector G ...Frame/Housing .040 thick aluminum spun parabolic reflector. Reflector is available in iridescent free Black, Clear, Gold, Haze, Warm Haze Alzak®, or painted gloss white finish. Special cone colors listed below. Hot dipped galvanized 20 gauge steel frame with built in 1/2 inch plaster lip. Gunsights allow for consistent alignment. One piece 20 gauge steel housing for seamless construction is painted matte black for a visually dark interior. B ...Flange Self flange reflector or die-cast flange with either matte white or clear coat finish. Die-cast flanges are easily removed for field painting. Elements are keyed for proper insertion. C ...Attachment Positive torsion springs pull flange tight to ceiling. Mechanical light trap eliminates spill light at edge of flange or reflector. D ...Socket Nickel plated porcelain socket. Two position socket ensures consistent lamp position. E ...Electrical Keyed quick connect provides easy lamp module installation. F ...Junction Box H ...Bar Hangers No Flex® bar hangers with positive locking, for use with wood, engineered wood and steel frame joists spaced up to 24" O.C. shipped with platform. For use in T-bar ceilings order accessory MBCLP clips. Nailess barb and locator lip provide consistent installation height. 8 1/2" [216mm] 16 1/2" [419mm] 4 15/16" [126mm] 8 1/2" [216mm] Ceiling Cutout 6 1/4" [159mm] Codes Thermally protected, IP labeled, Unit is airtight and exchanges less than 2.0 CFM with the plenum at a pressure of 75 pascals. Insulation must be kept three inches away from fixture sides and none on top as to entrap heat. Labels UL and cUL listed, standard damp label, IBEW union made. 18 cubic inches, listed for 4#12 AWG or 6#14 AWG 90° C additional feed through conductors, has five 1/2 inch pryouts. O R D E R I N G I N F O R M AT I O N Complete unit consists of a platform, module and element Optical Platform Lamp Module Element PN5 PN5=5" Airtight Non IC Housing Finish Flange Accessories Blank=White die-cast SF=Self Flange RAW=Natural Die-cast SFWF=Self Flange Painted White MBCLP=40 Push On T Bar Clips (for 10 Units) PLE5=Plaster Lip Extension for Max 2" Thick Ceiling FMC5=Flush Mount Collar M120 M120=Medium Base Incandescent Socket COOPER LIGHTING E5P30= 5" PAR 30 Downlight Reflector Standard B=Black C=Clear H=Haze G=Gold WMH=Warm Haze W=Gloss White MW=Matte White Custom K=Cognac KH=Cognac Haze CC=Chocolate Custom Cont. CCH=Chocolate Haze BU=Blush BUH=Blush Haze GP=Graphite GPH=Graphite Haze PN=Pine PNH=Pine Haze SK=Sky SKH=Sky Haze For additional options please consult factory. ADI030693 Unit Number: P N 5 - M 1 2 0 - E 5 P 3 0 C _ PHOTOMETRICS PN5-M120-E5P30C Candelas Test No. Vertical Angle 90 85 75 65 55 45 35 25 15 5 0 H36100 Lamp: 75PAR30/FL Lumens: 1100 Cutoff: Spacing: Efficiency: Unit LPW: 50° 0.5 94.1% 13.90 Distribution Luminance CD 0 0 0 0 0 133 60 324 1858 2547 2776 Cone of Light cd/m2 0 Degree 85˚ 75˚ 0 65˚ 0 55˚ 0 45˚ 13463 Distance to Illuminated Plane Initial Nadir Footcandles Beam Diameter 136 91 65 43 28 19 4'6" 5'6" 6'6" 8'0" 10'0" 12'0" 3'0" 3'6" 4'0" 5'0" 6'0" 7'6" 0° Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens 914 956 1035 1035 0 1035 %Lamp 83.1 87.0 94.1 94.1 0.0 94.1 Coefficient of Utilization %Luminaire 88.3 92.4 100.0 100.0 0.0 100.0 PN5-M120-E5P30C Candelas Test No. Vertical Angle 90 85 75 65 55 45 35 25 15 5 0 H36103 Lamp: 65BR30/FL Lumens: 770 Cutoff: Spacing: Efficiency: Unit LPW: 50° 0.8 81.6% 13.90 Ceiling Reflectance Wall Reflectance Room Cavity Ratio 0 1 2 3 4 5 6 7 8 9 10 70 50 80% 30 10 50 10 50 10 50 10 0% 0 112 109 105 102 112 107 102 98 112 105 99 95 112 103 97 93 110 105 97 97 110 102 92 92 105 101 98 95 105 99 94 91 100 97 95 93 100 96 92 89 94 91 89 87 99 97 94 91 89 87 84 95 91 89 86 83 81 78 91 88 85 82 79 77 75 89 85 82 79 77 74 72 94 91 88 85 83 80 78 88 85 82 79 77 74 72 92 89 87 84 82 79 77 87 84 82 79 76 74 72 90 88 86 83 81 79 77 86 83 81 78 76 74 72 84 82 80 77 75 71 71 Distribution 70% Luminance CD 0 0 0 1 2 76 147 429 724 770 768 30% Cone of Light cd/m2 0 Degree 85˚ 50% 75˚ 0 65˚ 102 55˚ 275 45˚ 7703 Distance to Illuminated Plane Initial Nadir Footcandles Beam Diameter 38 25 18 12 8 5 4'6" 5'6" 6'6" 8'0" 10'0" 12'0" 4'0" 5'0" 5'6" 7'0" 9'0" 10'6" 0° Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens 469 564 628 629 0 629 %Lamp 61.0 73.3 81.5 81.6 0.0 81.6 Coefficient of Utilization %Luminaire 74.7 89.8 99.9 100.0 0.0 100.0 Ceiling Reflectance Wall Reflectance Room Cavity Ratio 0 1 2 3 4 5 6 7 8 9 10 70 50 80% 30 10 50 70% 10 50 50% 10 50 30% 10 0% 0 97 93 90 87 83 80 77 74 71 68 65 97 91 87 82 78 74 71 67 64 61 58 97 90 84 79 75 70 67 63 60 57 54 97 88 82 76 72 68 64 60 57 54 51 95 90 85 81 77 74 70 67 64 61 58 95 87 81 76 71 67 64 60 57 54 51 91 86 83 79 76 72 69 66 63 60 57 91 84 79 75 71 67 64 60 57 54 51 87 83 80 77 74 71 68 65 62 59 57 87 82 77 73 70 66 63 60 57 54 51 82 78 75 71 68 65 62 58 56 53 50 Notes and Formulas: Luminance: To convert cd/m2 to footlamberts, multiply by 0.2919 Cone of Light: • Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. • Footcandle values are initial. Apply appropriate light loss factors where necessary. See page 64-65 of catalog. CU Notes/Formulas: • maintained illuminance=lamp lumens x CU x light loss factors room area • total number of luminaires=total room area x maintained illuminance lamp lumens x CU x light loss factors • CU data based on 20% effective floor cavity reflectance. Note: Specifications and Dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 ADI030693 Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049