DESCRIPTION
Specification grade 32 Watt triple tube compact fluorescent
wall wash fixture rated for direct contact with insulation. The
AIRTITE™ housing prevents airflow between attic and living
areas. The stepped kicker reflector maximizes light towards the
wall for smooth, pattern free illumination. Cutoff to lamp and
lamp image is 50°.
®
Type
Catalog #
Project
Date
Comments
Prepared By
S P E C I F I C AT I O N F E AT U R E S
Reflector/Lens
High purity 0.040° thick machine-spun
aluminum parabolic reflector in a
broad range of finishes.
Kicker
Injection molded, vacuum metalized
stepped optics with hardcoat finish
is specular clear. Available in single
(120°), double (2)120° @ 180° apart for
corridors), corner (240° for inside
corners), and half (60° for outside
corners or doors) versions.
Flange
Self-flanged reflector or die-cast
flange with either matte white or clear
coat finish. Die-cast flanges are easily
removed for field painting. Elements
are keyed for proper insertion.
Attachment
Positive torsion springs pull flange
tight to ceiling. Mechanical light trap
eliminates spill light at edge of flange
or reflector.
Lamp Socket
4 pin Gx24 (q-3) + (q-4) base for
26/32W PLT, TBX and TTT lamps.
Fatigue free stainless steel spring
ensures positive lamp retention. Fixed
socket height ensures consistent lamp
position.
Electronic Ballast
Thermally protected, current
controlled rapid start 120VAC Input
ballast produces full light output and
rated lamp life. Meets stringent FCC
requirements for EMI/RFI consumer
limits.
Lamp
Generic Compact Fluorescent Lamp
Designations (by others)
• CFTR26W/GX24q 2700K
• CFTR26W/GX24q 3000K
• CFTR32W/GX24q 2700K
• CFTR32W/GX24q 3000K
12,000 hour rated average life. 82 CRI
rated lamps provide excellent color
and high visual comfort.
Color temperature (warm to cool)
options offer 2700K warm or 3000K
medium warm incandescent-like light.
Frame/Housing
Hot dipped galvanized 20 gauge steel
frame with built in 1/2 inch plaster lip.
Aluminum .032 thick housing allows
for heat dissipation and reduces
weight.
Junction Box
18 cubic inches, listed for 4 #12
AWG or 6 #14 AWG 90° C additional
feed through conductors, has
(6) 1/2 inch pryouts.
Bar Hangers
No Flex® bar hangers with positive
locking, for use with joists spaced
up to 24" O.C. ship with platform.
Integralnail and locator lip provide
consistent installation height.
Codes
Thermally protected, IP labeled for
use in direct contact with insulation.
Compliance
• State of California Title 24
• Washington State Energy Code
• New York State Energy Conservation
Construction Code
• International Energy Conservation Code
P532ICAT
E5TWW
26/32W TTT
Compact Fluorescent
5-Inch Wall Wash Downlight
Labels
UL and cUL listed, standard wet label,
IBEW union made.
9"
[229mm]
15-3/4"
[401mm]
7-7/8"
[201mm]
10"
[254mm]
Ceiling Cutout 6-1/6" [159mm]
ENERGY DATA
EMI/RFI Emissions FCC Part 18 Consumer Limits
Input Frequency 50/60 Hz
Power Factor > 0.98
THD < 10%
Input Voltage 120V
26W
32W
Input Power
29W
Input Current
.24A
Input Power
36W
Input Current
0.306
5-1/4"
[134mm]
6-1/4"
[159mm]
6-3/4"
[172mm]
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADI041415
2012-03-26
IRIS
O R D E R I N G I N F O R M AT I O N : C o m p l e t e l u m i n a i r e c o n s i s t s o f a h o u s i n g p l a t f o r m a n d o p t i c a l e l e m e n t . ®
P 5 3 2 I C AT E 5 TW W
Example: P532ICAT + E5TWW
P l a t fo rm
Optical Element
P532ICAT
E5TWW
P532ICAT = 5" Airtight IC rated
housing with electronic ballast
120V input
Finish
E5TWW = 5" Wall Wash
E5TDWW = 5" Double Wall Wash
E5TCWW = 5" Corner Wall Wash
E5THWW = 5" Half Wall Wash
Alzak® Finishes
B = Black
C = Clear
CC = Chocolate
CCH = Chocolate Haze
G = Gold
GP = Graphite
GPH = Graphite Haze
H = Clear Haze
WMH = Warm Haze
Flange
K = Cognac
KH = Cognac Haze
WH = Wheat
WHH = Wheat Haze
Painted Finishes
MB = Matte Black
MW = Matte White
W = Gloss White
A c c e s s o ri e s
[Blank] = Matte White Die-cast Flange
POL = Polished Aluminum Die-cast Flange
RAW = Natural Die-cast Flange
SAL = Satin Aluminum Die-cast Flange
SF = Self-flange
SFWF = Self-flange Painted White
P H OTO M E T R I C S Photometric Results
P 5 3 2 I C AT E 5 TW W
Candlepower Distribution
Efficiency = 33.4%
Wall Wash
Candelas
Candlepower Distribution
Downlight
CD
Vertical
CD
Wall Wash Angle Downlight
Test No. H36086
0
8
28
49
80
176
326
440
523
528
510
Platform = P532ICAT
Element = E5TWWC
Lumens = 2400
Lamp = 32W PLT
32TTT
Luminance
24" O.C.
30
44
38
26
17
11
8
6
4
3
24
34
30
31
15
10
7
5
4
3
75º
0
65º
0
55º
0
45º
10649
32" O.C.
DD
29
44
40
28
18
12
8
6
4
3
0
1
2
3
4
5
6
7
8
9
10
10
16
15
10
6
4
3
2
1
1
1'
2'
3'
4'
6
9
11
9
6
4
3
2
1
1
3
3
5
6
4
3
2
2
1
1
1
1
1
3
3
2
2
1
1
1
0
0
0
0
1
1
1
1
1
1
2'6" Distance From Wall
24" O.C.
DD
30
44
38
26
17
11
8
6
4
3
85º
DD
0˚
2'0" Distance From Wall
18" O.C.
Single Fixture 2'0" Distance From Wall
2
Degree cd/m
@ 180º
0
0
0
0
0
105
336
490
581
604
510
90
85
75
65
55
45
35
25
15
5
0
0˚
1'6" Distance From Wall
1
2
3
4
5
6
7
8
9
10
PLE5 = Plaster Lip
Extension for Max 2"
Thick Ceiling
FMC5 = Flush Mount
Collar
21
33
30
22
15
11
7
5
4
3
24
34
30
31
15
10
7
5
4
3
1
2
3
4
5
6
7
8
9
10
24" O.C.
32" O.C.
DD
15
22
25
21
16
12
9
6
5
4
15
21
25
23
17
12
9
7
5
4
15
22
25
21
16
12
9
6
5
4
12
19
19
17
13
10
8
6
5
4
10
13
20
17
14
10
8
6
5
4
12
19
19
17
13
10
8
6
5
4
1
2
3
4
5
6
7
8
9
10
10
14
19
19
16
13
10
7
6
4
10
14
19
19
16
13
10
7
6
4
11
14
19
20
17
14
10
8
6
5
N OT E S A N D F O R M U L AS 8
11
14
15
13
11
8
7
5
4
8
10
14
15
14
11
9
7
5
4
8
11
14
15
13
11
8
7
5
4
P 5 3 2 I C AT E 5 TW W
• Illuminance values for multiple fixtures are based upon the center two units of a four unit array.
Footcandle values are centerline of fixtures and centered between fixtures.
• Illuminance values are cosine corrected initial values with no contribution from inter reflections from
other room surfaces. Total illumination may increase from contributions from other surfaces.
• DD=Distance Down from Ceiling.
Spacing
Between Fixtures
Distance
From Wall
DD=Distance Down
From Ceiling
New Fc = Exisiting Spacing x Average Table Fc Level
New Spacing
• When selecting colored cones option, only downlight cone is colored; the wall wash reflector is specular
clear. This allows the color (CRI, °K) of the light source to be unaffected and maximizes lumen output.
For optimal wall washing, space fixtures no more than 1.5 times the distance from the wall. CL
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
CL
ADI041415
2012-03-26
Download