Metalux D ES C R IPTION The Paralux IV Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 4" precision cell louver into a 6-3/4" deep para-contoured fixture housing. This combination creates a high comfort parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The high comfort luminaire is designed to provide a superior visual environment plus the higher shielding louver angle offers excellent cut-off for today‘s lighting requirements. The Paralux IV series is an excellent choice for commercial spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n 6-3/4" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Deep “V” ballast/wireway cover easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have labor saving integral Grid-Lock feature for safety and convenience. Housing features enable fixture to be converted from Grid to T-option or vice versa in the field.* E le ctrica l* * Ballast are CBM/ETL Class "P" and are positively secured. 2G11 base lampholders have doubleedge wiping action pressure lock contacts with vertically oriented lamp support clips. UL/CUL listed. Suitable for damp locations. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. H inging/Latching Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. Louver Die formed of semi-specular, vertical grain, aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. 2 P GAX 2BX40 3BX40 9 Cell 6-3/4" [172mm] 2' X 2' PARABOLIC 2 OR 3 BIAXIAL SINGLE ENDED LAMPS SEMI-SPECULAR LOUVER Paralux IV Recessed Air Supply Troffer 23-3/4" [603mm] ENERGY DATA MO UNTING D A TA 2 LAMP 7/8" [22mm] K.O. (2) M O U N T I N G DATA Access Plate 7/8" [22mm] K.O. (2) 3 LAMP 7/8" [22mm] K.O. (4) L A MP CONF IGURA T IONS Access Plate 7/8" [22mm] (2) 2 LAMP – 9 CELL 6-3/4" [172mm] 4" [102mm] 23-3/4" [603mm] 23-3/4" [603mm] 10-1/2" [267mm] 23-3/4" [603mm] Input Watts: EB Ballast & STD Lamps 2BX40 (67), 3BX40 (110) Luminaire Efficacy Rating LER = FP-55 Catalog Number: 2PGAX-2BX40 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.40 3 LAMP – 9 CELL 3-5/8" [93mm] 1-3/4" [45mm] 6-7/8" [176mm] 24" [608mm] 3-5/8" [93mm] 1-3/4" [45mm] 24" [608mm] 6-7/8" [176mm] **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 6-3/4" [172mm] 4" [102mm] 10-1/2" [267mm] 23-3/4" [603mm] C EILING C OM PA TA BI L I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ (Verify compatibility/ consult factory.) LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF090544 2015-10-13 16:51:57 PH OTOM ETR IC S Candlepower 2PGAX-2BX40S33I Electronic Ballast F40BX/SPX35/RS Lamps 3150 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.6 x mounting height Efficiency 63% Test Report: 2PGX2BX40S33I.IES LER = FP-55 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.40 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1776 1762 1721 1669 1601 1520 1420 1307 1179 1026 843 609 298 106 43 21 10 3 0 Across ⊥ 1776 1806 1807 1693 1608 1526 1518 1551 1607 1537 1124 806 501 177 77 36 14 3 0 45° 1776 1777 1777 1709 1597 1491 1366 1284 1231 1186 1070 785 407 126 51 25 12 4 0 75 68 62 56 51 46 42 38 34 31 28 75 66 59 52 47 42 37 33 29 26 23 75 65 56 49 43 38 34 29 26 23 20 73 69 65 60 56 52 48 44 41 38 35 73 67 61 55 50 46 41 37 34 30 28 73 65 58 52 46 41 37 32 29 26 23 73 64 56 49 43 38 33 29 26 23 20 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 1345 2197 3760 3970 3970 %Lamp 21.4 34.9 59.7 63.0 63.0 F40BX/SPX35/RS Lamps 3150 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.7 x mounting height Efficiency 65.4% Test Report: 2PGX3BX40S33I.IES LER = FP-55 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.33 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2766 2750 2691 2613 2512 2393 2247 2082 1888 1656 1366 997 481 171 67 33 14 4 0 Across ⊥ 2766 2783 2832 2948 3100 3213 3158 2703 1941 1393 1032 864 584 239 97 43 17 3 0 45° 2766 2753 2742 2735 2750 2768 2749 2644 2340 1777 1165 756 426 162 67 33 14 3 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 75 71 66 61 57 53 49 45 42 39 36 Candlepower 2PGAX-3BX40S33I Electronic Ballast Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 2 P GAX-2 B X4 0 P H OT OME T RICS %Fixture 33.9 55.4 94.7 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 70 64 59 54 49 44 40 36 33 30 27 67 62 57 52 48 43 39 35 32 29 27 64 60 55 51 46 42 38 35 31 28 26 70 63 57 51 45 41 36 32 29 26 23 70 62 54 48 43 38 33 29 26 23 20 67 61 55 49 45 40 36 31 28 25 23 67 60 53 47 43 37 33 29 25 22 20 10% 30 10 64 59 54 48 44 39 35 31 28 25 22 64 58 52 46 42 37 33 28 25 22 20 0% 0 63 57 51 45 40 36 31 27 24 21 19 Ty p i c a l VC P Pe r c e n t a g e s Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 79 74 84 79 87 83 87 84 89 86 Height Across 8.5’ 10.0’ 73 68 80 75 83 78 83 79 86 82 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 78 73 69 64 60 56 52 48 45 42 39 78 71 65 59 54 50 45 41 37 34 31 78 78 69 65 62 59 55 52 50 47 45 41 40 37 35 33 322 29 29 26 26 23 76 72 68 63 59 55 51 47 44 41 38 76 70 64 58 54 49 44 40 37 33 30 76 68 61 55 50 44 40 36 32 29 26 76 66 59 52 46 41 37 32 29 26 23 20% 50% 50 30 10 30% 50 30 10 50 73 67 62 57 52 48 43 39 36 33 30 70 65 60 55 51 46 42 38 35 32 29 67 62 58 54 49 45 41 38 34 31 29 73 66 59 54 49 44 39 35 32 28 26 73 64 57 51 46 41 36 32 29 26 23 70 64 58 53 48 43 39 35 31 28 25 70 62 56 50 45 40 36 32 29 25 23 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 2326 3867 5914 6178 6178 %Lamp 24.6 40.9 62.6 65.4 65.4 %Fixture 37.7 62.6 95.7 100.0 100.0 10% 30 10 67 61 56 51 47 42 38 34 31 28 25 Height Along 8.5’ 10.0’ 73 66 80 73 83 77 82 78 85 81 67 61 55 49 45 40 36 32 28 25 22 0% 0 65 59 54 48 44 39 35 31 27 24 21 Height Across 8.5’ 10.0’ 74 67 80 73 83 77 83 78 86 81 ORDER ING INFOR M A TION SAMPLE NUMBER: 2PGAX-2BX40S33I-120V-EB51-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' width P=Paralux IV Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (7) F=Aluminum Flange Trim (8) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Voltage (4) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (5) Number of Lamps 2=2 Lamps 3=3 Lamps (3) Wattage (Length) BX40=40W Biax (24") Louver Color S=Silver W=White Cell Configuration 33=3 Rows of 3, 9 Cell (2' x 2') Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps=Lamps Installed (refer to lamp ordering options) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (6) Ballast Type Blank=Standard Magnetic Ballast (Biax & 20W) EB5 =T5 Biax Electronic Instant Start. (9) Total Harmonic Distortion < 20% No. of Ballast 1 or 2 TEB5 =T5 Biax Electronic Instant Start. (9) Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER5 =T5 Biax Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Option – Aluminum Flange Trim (8) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row (1) (2) Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) SH IP P ING D A T A Catalog No. 2PGAX-2BX40S33I 2PGAX-3BX40S33I Wt. 29 lbs. 29 lbs. NOTES: Integral End Plate Grid Lock feature not available in Heat Removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (3) (4) (5) Standard off-center ballast on 3-lamp fixtures. Products also available in non-US voltages and frequencies for international markets. Not available when specify(6) ing emergencies, voltage must be specific. Fixtures equipped with “EL” option may require a 7-1/2" housing depth. If installing in field, must use low profile battery (7) (8) (9) pack. Louver is recessed by 5/16" in Concealed T or Slot Grid T. Specify row configuration, type in catalog number when ordering complete fixture. Not available in UNV voltages. Must specify voltage. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADF090544 2015-10-13 16:51:57