Metalux D ES C R IPTION The Standard Parabolic is a value driven luminaire designed and manufactured for value engineered applications. The luminaire features a nominal 3" deep precision cell parabolic louver and a 4-3/4" deep para-contoured housing for glare control and optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The Standard Parabolic is designed to offer maximum value in price sensitive applications. The luminaire is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * Louver 4-3/4" deep, para-contoured housing, die formed of code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Contoured ballast/ wireway cover is easily removed. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy gauge end plates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Die formed of low iridescent, vertical grain anodized aluminum. Finish is Anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. 2EP3GX 2U1-5/8 3U1-5/8 Hin g in g /L a tch ing Positive spring loaded, self locking, steel latches. Safety lock T-hinges allow hinging and latching from either side. 9, 12, 16 Cell 4-3/4" [121mm] 23-3/4" [603mm] 2' X 2' PARABOLIC 2 OR 3 LAMP T8 SEMI-SPECULAR, SPECULAR OR WHITE PAINTED LOUVER Paralux III Recessed Static or Air Supply Troffer MOUNTING D A TA 2 LAMP 7/8" [22mm] K.O. (2) Access Plate 7/8" [22mm] K.O. (2) 3 LAMP Access Plate 7/8" [22mm] (2) 7/8" [22mm] K.O. (4) 23-3/4" [603mm] 23-3/4" [603mm] ENERGY DATA 3-5/8" [93mm] 3-5/8" [93mm] 1-3/4" [45mm] 1-3/4" [45mm] 6-7/8" [176mm] 6-7/8" [176mm] Input Watts: EB Ballast & STD Lamps 2U1-5/8 (61), 3U1-5/8 (91) 24" [608mm] 24" [608mm] L AM P C ONFIGUR A TI O N S 2 LAMP – 9/12 CELL 2 LAMP – 16 CELL 4-3/4" [121mm] 2-5/8" [67mm] X=1-5/8" [41mm] 3 LAMP – 9/12 CELL 4-3/4" [121mm] X 8-7/8" X [225mm] 23-3/4" [603mm] 2-5/8" [67mm] X=1-5/8" [41mm] Luminaire Efficacy Rating LER = FP-55 Catalog Number: 2EP3GX-2U15/8S33I Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.36 4-3/4" [121mm] X 8-7/8" X [225mm] 23-3/4" [603mm] 2-5/8" [67mm] X=1-5/8" [41mm] X X X 5-3/8" 5-3/8" [137mm] [137mm] 23-3/4" [603mm] C EILING C OM PA TIB IL I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ (Verify compatibility/ consult factory.) **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF090227 2013-02-04 15:18:46 2 E P 3 GX-2 U1 -5 / 8 PH OTOM ETR IC S 2EP3GAX-3U1-5/8S33I C a n d l e p o w e r Electronic Ballast FB031/41K Lamps 2800 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 61.9% Test Report: 2EP3GAX3U158S33I.IES LER = FP-53 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.53 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2280 2263 2216 2157 2082 1983 1872 1738 1583 1412 1208 968 648 270 75 26 11 2 0 Across ⊥ 2280 2289 2312 2339 2359 2360 2269 2049 1895 1576 958 513 294 122 50 25 11 2 0 45° 2280 2272 2261 2245 2216 2169 2107 1996 1803 1555 1282 861 425 174 57 24 11 2 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 74 67 60 54 48 44 40 36 33 31 28 74 65 57 50 44 39 35 31 28 26 24 74 63 54 46 40 35 31 28 25 23 21 72 67 63 58 53 50 46 43 40 37 35 72 65 59 53 48 43 39 36 33 30 28 72 64 56 49 43 39 35 31 28 26 23 72 62 53 46 40 35 31 28 25 23 21 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 1855 3068 4962 5201 5201 %Lamp 22.1 36.5 59.1 61.9 61.9 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 FBO31/35K Lamps 2750 Lumens || Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height ⊥ Efficiency 60.7% Test Report: 2EP3GX2U158S33I.IES LER = FP-55 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.36 Along II 1393 1387 1358 1320 1269 1206 1132 1046 950 841 718 577 389 177 58 20 8 2 0 Across ⊥ 1393 1383 1357 1308 1286 1327 1307 1226 1173 1126 1051 874 506 146 46 23 11 4 0 45° 1393 1385 1358 1310 1251 1193 1169 1140 1058 948 849 728 519 238 58 20 8 2 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 74 69 64 59 55 51 47 44 41 38 36 Candlepower 2EP3GX-2U1-5/8S33I Electronic Ballast %Fixture 35.7 59.0 95.4 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 69 63 57 51 46 42 38 35 32 29 27 66 61 55 50 45 41 37 34 31 29 27 63 58 53 48 44 40 36 33 31 28 26 69 61 54 48 42 38 34 31 28 25 23 69 60 52 45 40 35 31 28 25 22 20 66 59 53 47 42 37 33 30 27 25 23 66 58 51 44 39 34 31 27 25 22 20 10% 30 10 63 57 51 46 41 37 33 30 27 25 23 63 57 50 44 39 34 30 27 25 22 20 0% 0 62 55 49 42 37 33 29 26 23 21 19 Ty p i c a l VC P Pe r c e n t a g e s Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 71 64 79 73 83 78 81 77 84 81 Height Across 8.5’ 10.0’ 78 74 84 79 86 82 86 82 88 85 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 72 67 62 57 53 48 45 42 39 36 34 72 65 58 52 46 41 37 34 31 28 26 72 63 54 47 41 36 32 29 26 24 21 72 61 51 44 38 33 29 25 23 20 18 71 66 61 56 51 47 44 41 38 35 33 71 64 57 51 45 41 37 33 30 28 26 71 62 54 47 41 36 32 29 26 23 21 71 60 51 43 37 32 28 25 23 20 18 20% 50% 50 30 10 30% 50 30 10 50 67 61 55 49 44 39 36 32 30 27 25 65 59 53 47 42 38 35 32 29 27 25 62 57 51 46 41 37 34 31 28 26 24 67 60 52 45 40 35 31 28 25 23 21 67 58 50 43 37 32 28 25 22 20 18 65 58 51 44 39 35 31 28 25 23 21 65 56 49 42 36 32 28 25 22 20 18 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 1073 1779 3154 3397 3397 %Lamp 19.2 31.8 56.3 60.7 60.7 %Fixture 31.6 52.4 92.8 100.0 100.0 Height Along 8.5’ 10.0’ 75 69 82 76 85 81 85 80 87 84 10% 30 10 62 56 49 43 38 34 30 27 25 23 21 62 55 48 41 36 31 28 25 22 20 18 0% 0 61 54 46 40 35 30 27 24 21 19 17 Height Across 8.5’ 10.0’ 74 67 81 75 84 79 83 78 86 82 ORDER ING INFOR M A TION SAMPLE NUMBER: 2EP3GAX-2U1-5/8S33I-UNV-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' Width EP=Paralux Louver 3=3" Louver Depth Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (7) F=Aluminum Flange Trim (8) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Voltage (4) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (5) Number of Lamps 2=2 Lamps 3=3 Lamps (3) Wattage (Length) U1-5/8=31W T8 (24") Louver Color S=Silver W=White Cell Configuration 33=3 Rows of 3, 9 Cell 34=3 Rows of 4, 12 Cell 44=4 Rows of 4, 16 Cell Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard (Silver Only) MI=Specular/Mirrored (Low Iridescent) (Silver Only) P=Painted (White only) Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps=Lamps Installed (refer to lamp ordering options) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (6) Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton No. of Ballast 1, 2 or 3 ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) Option – Aluminum Flange Trim (8) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row SH IP P ING D A T A (1) (2) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fix(3) (4) (5) ture. Standard off-center ballast on 3-lamp fixtures. Products also available in non-US voltages and frequencies for international markets. Not available (6) when specifying emergencies, voltage must be specific. Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must use (7) (8) low profile battery pack. Louver is recessed by 5/16" in Concealed T or Slot Grid T. Specify row configuration, type in catalog number when ordering complete fixture. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Catalog No. 2EP3GX-2U1-5/8S33I 2EP3GX-2U1-5/8S44I 2EP3GX-3U1-5/8S33I 2EP3GX-3U1-5/8S34I 2EP3GX-3U1-5/8S44I Wt. 28 lbs. 28 lbs. 28 lbs. 28 lbs. 28 lbs. ADF090227 2013-02-04 15:18:46