COOPER LIGHTING - METALUX ® DESCRIPTION The Paralux IV Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 4" precision cell louver into a 6-3/4" deep para-contoured fixture housing. This combination creates a high comfort parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The high comfort luminaire is designed to provide a superior visual environment plus the higher shielding louver angle offers excellent cut-off for today‘s lighting requirements. The Paralux IV series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES Construction E l e c t r i c a l ** H i n g i n g / L a t ch i n g 6-3/4" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Deep “V” ballast/wireway cover easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have labor saving integral GridLock feature for safety and convenience. Housing features enable fixture to be converted from Grid to T-option or vice versa in the field.* Ballast are CBM/ETL Class “P” and positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. Finish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Louver Die formed of semi-specular, vertical grain, aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. 2PGAX 2U1-5/8 3U1-5/8 9 Cell 2' X 2' PARABOLIC 2 OR 3 T8 LAMPS SEMI-SPECULAR LOUVER Paralux IV Recessed Air S u p p l y Tr o f f e r 6-3/4" [172mm] 23-3/4" [603mm] LAMP CONFIGURATIONS MOUNTING DATA Access Plate 7/8" [22mm] K.O. (2) 7/8" [22mm] K.O. (2) 2 LAMP 3 LAMP 7/8" [22mm] K.O. (4) Access Plate 7/8" [22mm] (2) 2 LAMP – 9 CELL ENERGY DATA 6-3/4" [172mm] X 4" [102mm] X=1-5/8" [41mm] 23-3/4" [603mm] 23-3/4" [603mm] Input Watts: EB Ballast & STD Lamps 2U1-5/8 (61), 3U1-5/8 (91) 8-7/8" X [225mm] 23-3/4" [603mm] Luminaire Efficacy Rating LER = FP-50 Catalog Number: 2PGAX-2U1-5/8 3 LAMP – 9 CELL 3-5/8" [93mm] 1-3/4" [45mm] 6-7/8" [176mm] 24" [608mm] 3-5/8" [93mm] 1-3/4" [45mm] 6-7/8" [176mm] 24" [608mm] CEILING COMPATIBILITY G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates 6-3/4" [172mm] 4" [102mm] X=1-5/8" [41mm] MZ Modular Trim With Supporting Swing Gates X X X 5-3/8" 5-3/8" [137mm] [137mm] 23-3/4" [603mm] Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ (Verify compatibility/ consult factory.) COOPER LIGHTING Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.90 **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF090546 2 P G A X - 2 U 1- 5 / 8 PHOTOMETRICS 2PGAX-2U1-5/8S33I Electronic Ballast FBO31/35K Lamps 2800 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 57.5% Test Report: 2PGX2U158S33I.IES LER = FP-50 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.90 Candlepower Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1387 1375 1342 1296 1240 1170 1094 1004 906 794 661 495 255 88 35 18 9 2 0 2PGAX-3U1-5/8S331I C a n d l e p o w e r Electronic Ballast Across ⊥ 1387 1383 1343 1286 1280 1286 1267 1254 1215 1125 981 697 415 151 62 29 11 2 0 45° 1387 1378 1343 1283 1212 1166 1134 1073 993 919 812 628 334 99 41 20 10 3 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 68 62 56 51 46 41 37 33 30 27 24 68 60 53 47 42 37 33 29 25 22 20 68 59 51 44 38 33 29 26 22 19 17 67 63 59 54 50 46 43 40 36 33 31 67 61 55 50 45 40 36 33 29 26 24 67 59 52 47 41 36 32 29 25 22 20 67 58 50 44 38 33 29 25 22 19 17 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 1046 1728 2963 3133 3133 %Lamp 19.2 31.7 54.4 57.5 57.5 Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 60.5% Test Report: 2PGX3U158S33I.IES LER = FP-57 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.20 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2233 2209 2157 2088 2001 1897 1778 1641 1483 1305 1085 808 410 137 54 28 15 5 0 Across ⊥ 2233 2243 2282 2332 2356 2313 2148 2016 1751 1359 1059 820 512 189 79 36 15 3 0 45° 2233 2232 2222 2209 2191 2146 2055 1878 1656 1424 1058 706 403 136 56 28 13 4 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 68 64 60 56 51 47 44 40 37 34 32 FB031/31K Lamps 2800 Lumens %Fixture 33.4 55.2 94.6 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 64 58 53 48 44 39 35 32 29 26 23 61 56 52 47 42 38 35 31 28 25 23 59 54 50 45 41 37 34 31 27 25 22 64 57 51 45 40 36 32 28 25 22 19 64 56 49 43 38 33 29 25 22 19 17 61 55 50 44 40 35 31 28 24 21 19 61 54 48 42 37 33 29 25 22 19 17 10% 30 10 59 53 48 44 39 35 31 27 24 21 19 59 53 47 42 37 32 28 25 22 19 16 0% 0 57 52 46 41 36 31 27 24 21 18 16 Typical VCP Percentages Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 83 78 87 83 90 86 89 86 91 88 Height Across 8.5’ 10.0’ 77 72 84 79 86 82 86 82 88 85 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 72 68 563 59 55 51 47 43 40 37 34 72 66 60 54 49 44 40 36 33 29 27 72 64 57 50 45 40 35 32 28 25 22 72 62 54 47 42 36 32 28 25 21 19 70 66 62 58 54 49 46 43 39 36 33 70 64 59 53 48 44 40 36 32 29 26 70 63 56 50 44 39 35 31 28 25 22 20% 70 61 53 47 41 36 32 28 25 21 19 50% 50 30 10 30% 50 30 10 50 67 62 56 52 47 42 38 35 31 28 26 64 59 55 50 46 41 38 34 31 28 25 62 57 53 49 44 40 37 33 30 27 25 67 60 54 49 43 39 35 31 27 24 22 67 59 52 46 41 36 32 28 25 21 19 64 58 53 48 43 38 34 30 27 24 21 64 57 51 45 40 35 31 28 24 21 19 Zonal Lumen Summary Typical VCP Percentages Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 1814 2968 4716 4944 4944 %Lamp 22.2 36.3 57.7 60.5 60.5 %Fixture 36.7 60.0 95.4 100.0 100.0 10% 30 10 Height Along 8.5’ 10.0’ 77 70 82 76 84 79 85 81 86 83 62 57 51 47 42 37 35 30 27 24 21 62 56 50 45 40 35 31 28 24 21 19 0% 0 60 55 49 44 39 34 30 27 23 20 18 Height Across 8.5’ 10.0’ 75 69 81 75 84 79 84 80 87 82 ORDERING INFORMATION SAMPLE NUMBER: 2PGAX-2U1-5/8S33I-UNV-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' width P=Paralux IV Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (7) F=Aluminum Flange Trim (8) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) (1) Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Number of Lamps 2=2 Lamps 3=3 Lamps (6) Wattage (Length) U15/8=31W T8 (24") Louver Color S=Silver W=White Cell Configuration 33=3 Rows of 3, 9 Cell (2' x 2') Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps=Lamps Installed (refer to lamp ordering options) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (5) Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 Options PAF=Painted After Fabrication RIF1=Radio Interference Suppressor REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) Option – Aluminum Flange Trim (8) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row (2) NOTES: Integral End Plate Grid Lock feature not available in Heat Removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (3) (4) Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific. (5) (6) Fixtures equipped with “EL” option may require a 7-1/2" housing depth. If installing in field, must use low profile battery pack. Standard off-center ballast on 3-lamp (7) (8) fixtures. Louver is recessed by 5/16" in Concealed T or Slot Grid T. Specify row configuration, type in catalog number when ordering complete fixture. SHIPPING INFORMATION Catalog No. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Wt. 2PGAX-3U1-5/8S33I 2PGAX-2U1-5/8S33I 29 lbs. 29 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 6/12 ADF090546