The Paralux IV Series features recessed aesthetics and the latest in

advertisement
COOPER LIGHTING - METALUX
®
DESCRIPTION
The Paralux IV Series features recessed aesthetics and the latest in
energy efficient technology. The luminaire incorporates a 4" precision
cell louver into a 6-3/4" deep para-contoured fixture housing. This combination creates a high comfort parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular
ceiling systems and is available with a number of options and accessories for application versatility. The high comfort luminaire is designed
to provide a superior visual environment plus the higher shielding louver angle offers excellent cut-off for today‘s lighting requirements. The
Paralux IV series is an excellent choice for commercial office spaces,
schools, hospitals or retail merchandising areas.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
Construction
E l e c t r i c a l **
H i n g i n g / L a t ch i n g
6-3/4" deep, para-contoured housing, die
formed code gauge, prime cold rolled
steel. Die embossed housing has full
length die formed stiffeners for added
strength. Deep “V” ballast/wireway cover
easily removed without tools. Die
formed captive lampholder bracket fully
encloses lampholder wiring permitting
easy lampholder replacement. Heavy
end plates, securely attached with interlocking tabs and screws. Four auxiliary
fixture end suspension points provided.
KOs for continuous row wiring. End
plates have labor saving integral GridLock feature for safety and convenience.
Housing features enable fixture to be
converted from Grid to T-option or vice
versa in the field.*
Ballast are CBM/ETL Class
“P” and positively secured
by mounting bolts.
Pressure lock lampholders. UL/CUL listed.
Suitable for damp locations.
Positive cam action spring
loaded, self locking, black steel
latches. Safety lock T-hinges
allow hinging and latching either
side.
Finish
Lighting grade, baked
white enamel finish.
Multistage, iron phosphate pretreatment
ensures maximum bonding and rust inhibition.
Louver
Die formed of semi-specular,
vertical grain, aluminum. Finish
is anodic oxide coating. Accurate
precision parabolic cells are held
in place with interlocking feature.
True-cut mitered corners. Black
reveal with integral mechanical
light seal around entire perimeter of louver. Louver protected
from construction contaminants
by polyethylene cover.
2PGAX
2U1-5/8
3U1-5/8
9 Cell
2' X 2' PARABOLIC
2 OR 3 T8 LAMPS
SEMI-SPECULAR
LOUVER
Paralux IV
Recessed Air
S u p p l y Tr o f f e r
6-3/4"
[172mm]
23-3/4"
[603mm]
LAMP CONFIGURATIONS
MOUNTING DATA
Access Plate
7/8" [22mm] K.O. (2)
7/8" [22mm]
K.O. (2)
2 LAMP
3 LAMP
7/8" [22mm]
K.O. (4)
Access Plate
7/8" [22mm] (2)
2 LAMP – 9 CELL
ENERGY DATA
6-3/4"
[172mm]
X
4"
[102mm]
X=1-5/8"
[41mm]
23-3/4"
[603mm]
23-3/4"
[603mm]
Input Watts:
EB Ballast & STD Lamps
2U1-5/8 (61), 3U1-5/8 (91)
8-7/8"
X
[225mm]
23-3/4" [603mm]
Luminaire Efficacy Rating
LER = FP-50
Catalog Number: 2PGAX-2U1-5/8
3 LAMP – 9 CELL
3-5/8" [93mm]
1-3/4" [45mm]
6-7/8" [176mm]
24" [608mm]
3-5/8" [93mm]
1-3/4" [45mm]
6-7/8" [176mm]
24" [608mm]
CEILING COMPATIBILITY
G
Grid/Lay-in
Standard
G
Concealed T
G
Slot Grid
F
Aluminum Flange Trim
With Supporting
Swing Gates
6-3/4"
[172mm]
4"
[102mm]
X=1-5/8"
[41mm]
MZ
Modular Trim
With Supporting
Swing Gates
X
X
X
5-3/8"
5-3/8"
[137mm] [137mm]
23-3/4" [603mm]
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
Concealed “T” or ”Z“
Metal Pan
G
G
G
F
MZ
MZ
(Verify compatibility/ consult
factory.)
COOPER LIGHTING
Yearly Cost of 1000 lumens, 3000
hrs at .08 KWH = $4.90
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO
LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF090546
2 P G A X - 2 U 1- 5 / 8
PHOTOMETRICS
2PGAX-2U1-5/8S33I
Electronic Ballast
FBO31/35K Lamps
2800 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency 57.5%
Test Report:
2PGX2U158S33I.IES
LER = FP-50
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.90
Candlepower
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1387
1375
1342
1296
1240
1170
1094
1004
906
794
661
495
255
88
35
18
9
2
0
2PGAX-3U1-5/8S331I C a n d l e p o w e r
Electronic Ballast
Across ⊥
1387
1383
1343
1286
1280
1286
1267
1254
1215
1125
981
697
415
151
62
29
11
2
0
45°
1387
1378
1343
1283
1212
1166
1134
1073
993
919
812
628
334
99
41
20
10
3
0
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
68
62
56
51
46
41
37
33
30
27
24
68
60
53
47
42
37
33
29
25
22
20
68
59
51
44
38
33
29
26
22
19
17
67
63
59
54
50
46
43
40
36
33
31
67
61
55
50
45
40
36
33
29
26
24
67
59
52
47
41
36
32
29
25
22
20
67
58
50
44
38
33
29
25
22
19
17
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
0-180
Lumens
1046
1728
2963
3133
3133
%Lamp
19.2
31.7
54.4
57.5
57.5
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency 60.5%
Test Report:
2PGX3U158S33I.IES
LER = FP-57
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.20
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
2233
2209
2157
2088
2001
1897
1778
1641
1483
1305
1085
808
410
137
54
28
15
5
0
Across ⊥
2233
2243
2282
2332
2356
2313
2148
2016
1751
1359
1059
820
512
189
79
36
15
3
0
45°
2233
2232
2222
2209
2191
2146
2055
1878
1656
1424
1058
706
403
136
56
28
13
4
0
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
68
64
60
56
51
47
44
40
37
34
32
FB031/31K Lamps
2800 Lumens
%Fixture
33.4
55.2
94.6
100.0
100.0
20%
50%
50 30 10
30%
50 30 10
50
64
58
53
48
44
39
35
32
29
26
23
61
56
52
47
42
38
35
31
28
25
23
59
54
50
45
41
37
34
31
27
25
22
64
57
51
45
40
36
32
28
25
22
19
64
56
49
43
38
33
29
25
22
19
17
61
55
50
44
40
35
31
28
24
21
19
61
54
48
42
37
33
29
25
22
19
17
10%
30 10
59
53
48
44
39
35
31
27
24
21
19
59
53
47
42
37
32
28
25
22
19
16
0%
0
57
52
46
41
36
31
27
24
21
18
16
Typical VCP Percentages
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Height Along
8.5’
10.0’
83
78
87
83
90
86
89
86
91
88
Height Across
8.5’
10.0’
77
72
84
79
86
82
86
82
88
85
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
72
68
563
59
55
51
47
43
40
37
34
72
66
60
54
49
44
40
36
33
29
27
72
64
57
50
45
40
35
32
28
25
22
72
62
54
47
42
36
32
28
25
21
19
70
66
62
58
54
49
46
43
39
36
33
70
64
59
53
48
44
40
36
32
29
26
70
63
56
50
44
39
35
31
28
25
22
20%
70
61
53
47
41
36
32
28
25
21
19
50%
50 30 10
30%
50 30 10
50
67
62
56
52
47
42
38
35
31
28
26
64
59
55
50
46
41
38
34
31
28
25
62
57
53
49
44
40
37
33
30
27
25
67
60
54
49
43
39
35
31
27
24
22
67
59
52
46
41
36
32
28
25
21
19
64
58
53
48
43
38
34
30
27
24
21
64
57
51
45
40
35
31
28
24
21
19
Zonal Lumen Summary
Typical VCP Percentages
Zone
0-30
0-40
0-60
0-90
0-180
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Lumens
1814
2968
4716
4944
4944
%Lamp
22.2
36.3
57.7
60.5
60.5
%Fixture
36.7
60.0
95.4
100.0
100.0
10%
30 10
Height Along
8.5’
10.0’
77
70
82
76
84
79
85
81
86
83
62
57
51
47
42
37
35
30
27
24
21
62
56
50
45
40
35
31
28
24
21
19
0%
0
60
55
49
44
39
34
30
27
23
20
18
Height Across
8.5’
10.0’
75
69
81
75
84
79
84
80
87
82
ORDERING INFORMATION
SAMPLE NUMBER: 2PGAX-2U1-5/8S33I-UNV-EB81-U
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
HR=Heat
Removal (1)
Width
2=2' width
P=Paralux IV
Trim Type
G=Grid/Lay-in (Standard)
G=Concealed T/Slot Grid (7)
F=Aluminum Flange Trim (8)
MZ=Modular Trim
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver
with Directional Air Vane (Add V)
(1)
Voltage (3)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (4)
Number
of Lamps
2=2 Lamps
3=3 Lamps (6)
Wattage (Length)
U15/8=31W T8 (24")
Louver Color
S=Silver
W=White
Cell Configuration
33=3 Rows of 3, 9 Cell (2' x 2')
Louver Finish
I=Semi-Specular/Haze (Low Iridescent)
Standard
MI=Specular/Mirrored (Low Iridescent)
P=Painted
Options
GL=Single Element Fuse
GM=Double Element Fuse
WTR=White Reveal
Lamps=Lamps Installed
(refer to lamp ordering
options)
Flex=Flex Installed
(Reference Flex ordering
information)
EL=Emergency Installed (5)
Ballast Type
EB8 =T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 /PLUS= T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of
High Ballast Factor >1.15
Ballast
1, 2 or 3
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
Options
PAF=Painted After
Fabrication
RIF1=Radio
Interference
Suppressor
REP=Riveted
Endplates
Packaging
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
ACCESSORIES
EQ-CLIP-U=T-BAR Safety Earthquake Clips(2)
Option – Aluminum Flange Trim (8)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
(2)
NOTES: Integral End Plate Grid Lock feature not available in Heat Removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.
(3)
(4)
Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific.
(5)
(6)
Fixtures equipped with “EL” option may require a 7-1/2" housing depth. If installing in field, must use low profile battery pack. Standard off-center ballast on 3-lamp
(7)
(8)
fixtures. Louver is recessed by 5/16" in Concealed T or Slot Grid T. Specify row configuration, type in catalog number when ordering complete fixture.
SHIPPING INFORMATION
Catalog No.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
Wt.
2PGAX-3U1-5/8S33I
2PGAX-2U1-5/8S33I
29 lbs.
29 lbs.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
6/12
ADF090546
Download