Metalux

advertisement
Metalux
D ES C R IPTION
The Paralux III Series features recessed aesthetics and the latest in energy
efficient technology. The luminaire incorporates a nominal 3" deep
precision cell louver into a 4-3/4" deep para-contoured fixture housing. This
combination creates a total high performance parabolic optical assembly for
optimum performance. The series is compatible with all of today’s popular
ceiling systems and is available with a number of options and accessories for
application versatility.
Catalog #
2EP3-IC is designed for installations when the housing will be in direct
contact with insulation. The high performance luminaire is designed to
offer maximum efficiency and performance for today’s unique interior
specifications.
Prepared by
Type
Project
Date
Comments
SPE C IFIC A TION FEA T U R E S
C on s t r u c t i o n
E le ctrica l* *
H inging/Latching
4-3/4" deep, para-contoured
housing, die formed of code
gauge, prime cold rolled steel.
Die embossed housing has full
length die formed stiffeners for
added strength. Contoured ballast/
wireway cover is easily removed.
Die formed captive lampholder
bracket fully encloses lampholder
wiring permitting easy lampholder
replacement. Heavy gauge end
plates are securely attached with
interlocking tabs and screws. Four
auxiliary fixture end suspension
points provided. KOs for
continuous row wiring. End plates
have integral Grid-Lock feature for
safety and convenience.
Ballasts are CBM/ETL Class “P” and
are positively secured by mounting
bolts. Pressure lock lampholders.
UL/CUL listed for Type IC Recessed
Luminaire (Rated for direct contact
with insulation) Suitable for damp
locations.
Positive spring loaded, self locking,
steel latches. Safety lock T-hinges
allow hinging and latching from
either side.
Louver
Die formed of low iridescent,
vertical grain anodized aluminum.
Finish is Anodic oxide coating.
Accurate precision parabolic
cells are held in place with
interlocking feature. True-cut
mitered corners. Black reveal with
integral mechanical light seal
around entire perimeter of louver.
Louver protected from construction
contaminants by polyethylene
cover.
F in ish
Lighting grade, baked white
enamel finish. Multistage, iron
phosphate pretreatment ensures
maximum bonding and rust
inhibition.
2EP3GAX-IC
2U6T8
6, 9, 16 Cell
2' X 2' PARABOLIC
2-U LAMPS
SEMI-SPECULAR,
SPECULAR OR WHITE
PAINTED LOUVER
4-3/4"
[121mm]
Paralux III
Recessed Static or
Air Supply Troffer
For Use in
Insulated Ceilings
23-3/4"
[603mm]
MO UNTING D A TA
2 LAMP
7/8" [22mm]
K.O. (2)
L A MP CONF IGURA T IONS
Access Plate
7/8" [22mm] K.O. (2)
2 LAMP – 6 CELL
4-3/4"
[121mm]
ENERGY DATA
4-5/8"
2-5/8"
X
X
[117mm]
[67mm]
X=6"
23-3/4" [603mm]
[152mm]
2 LAMP – 9 CELL
23-3/4"
[603mm]
Input Watts:
EB Ballast & STD Lamps
2U6T8 (61)
4-3/4"
[121mm]
3-5/8" [93mm]
1-3/4" [45mm]
6-7/8" [176mm]
24" [608mm]
2-5/8"
[67mm]
X=6"
[152mm]
X
4-5/8"
[117mm]
Luminaire Efficacy Rating
LER = FP-52
Catalog Number: 2EP3GAX-IC-2U6T8
X
23-3/4" [603mm]
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $4.62
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
CEI LING C OM PA TIB I L I T Y
G
Slot Grid
F
Aluminum Flange Trim
With Supporting
Swing Gates
MZ
Modular Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
Concealed “T” or ”Z“
Metal Pan
G
G
G
F
MZ
MZ
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
(Verify compatibility/ consult
factory.)
C
ER
TEM
S
YS
D
G
Concealed T
S
G
Grid/Lay-in
Standard
TIFIE
ADF110370
2013-03-26 16:25:48
2E P 3 GAX-IC -2 U6 T 8
PH OTOM ETR IC S
Coefficients of Utilization
2EP3GAX-IC-2U6T8S23I
Electronic Ballast
FB31T8/35K/6 Lamps
2600 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.3 x
mounting height
Efficiency 63.8%
Test Report:
2EP3GAXIC2U6T8S23I.IES
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
76
71
65
60
55
51
47
43
40
38
35
76
68
60
54
48
43
39
35
32
29
27
76
66
57
49
43
38
33
30
27
24
22
76
64
53
45
39
34
29
26
23
21
19
74
69
63
58
53
49
46
42
39
37
35
74
67
59
53
47
42
38
35
32
29
27
74
65
56
48
42
37
33
30
27
24
22
74
63
53
45
39
33
29
26
23
21
19
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
71
64
57
51
45
41
37
34
31
28
26
68
62
55
49
44
40
36
33
30
28
26
65
59
53
48
43
39
35
32
29
27
25
64
56
48
41
36
31
27
24
22
20
18
71
62
54
47
41
36
32
29
26
24
22
71
61
52
44
38
33
29
26
23
21
19
68
60
53
46
40
36
32
29
26
24
22
68
59
51
43
38
33
29
26
23
21
19
Zonal Lumen Summary
Typical VCP Percentages
Zone
0-30
0-40
0-60
0-90
0-180
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Lumens
%Lamp
%Fixture
1067
1717
2984
3317
3317
20.5
33.0
57.4
63.8
63.8
32.2
51.8
90.0
100.0
100.0
Height Along
8.5’ 10.0’
72
67
79
73
83
78
82
78
85
82
65
58
51
45
40
35
31
28
26
23
21
65
57
49
43
37
32
29
25
23
21
19
Height Across
8.5’ 10.0’
65
60
75
69
79
74
78
73
82
78
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Across ⊥
1314
1319
1338
1371
1383
1330
1174
Along II
1314
1303
1274
1234
1188
1129
1066
45°
1314
1311
1304
1300
1293
1266
1210
990
1089
998
909
812
708
586
422
204
65
21
7
4
0
920
773
698
647
547
327
102
25
9
4
0
902
880
924
950
754
327
100
26
10
4
0
LER = FP-52
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.62
ORDER IN G INFOR M A TION
SAMPLE NUMBER: 2EP3GAX-IC-3BX4036-MI-120V-EB51-U
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
HR=Heat
Removal (1)
Width
2=2' Width
EP=Paralux Louver
Voltage (4)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (5)
Number
of Lamps
2=2 Lamps
3=3 Lamps (3)
Wattage (Length)
BX40=40W Biax (24")
U6T8=32W T8 (24")
U15/8=31W T8 (24")
Louver Color/Type
ST=Silver Tannenbaum
Cell Configuration
36=3 Rows of 6, 18 Cell
3=3" Louver Depth
Trim Type
G=Grid/Lay-in (Standard)
G=Concealed T/Slot Grid (7)
F=Aluminum Flange Trim (8)
MZ=Modular Trim
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver
with Directional Air Vane (Add V)
Louver Finish
MI=Specular/Mirrored (Low
Iridescent) (Silver Only)
Options
GL=Single Element Fuse
GM=Double Element Fuse
WTR=White Reveal
Lamps=Lamps Installed
(refer to lamp ordering
options)
Flex=Flex Installed
(Reference Flex ordering
information)
EL=Emergency Installed (6)
Option – Aluminum Flange Trim (8)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
Ballast Type
EB8 =T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 /PLUS= T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of
High Ballast Factor >1.15
Ballast
1, 2 or 3
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB5 =T5 Biax Electronic Instant Start (9)
Total Harmonic Distortion < 20%
No. of Ballast
1, 2 or 3
TEB5 =T5 Biax Electronic Instant Start (9)
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
ER5 =T5 Biax Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
Options
PAF=Painted After
Fabrication
REP=Riveted
Endplates
Packaging
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
ACCESSORIES
EQ-CLIP-U=T-BAR Safety Earthquake Clips(2)
IC=IC Rated
(1)
(2)
NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per
(3)
(4)
(5)
fixture. Standard off-center ballast on 3-lamp fixtures. Products also available in non-US voltages and frequencies for international markets. Not avail(6)
able when specifying emergencies, voltage must be specific. Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field,
(7)
(8)
must use low profile battery pack. Louver is recessed by 5/16" in Concealed T or Slot Grid T. Specify row configuration, type in catalog number when
(9)
ordering complete fixture. Not available in UNV voltages. Must specify voltage.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper
Lighting Representative for availability and ordering information.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
SH IP P ING D A T A
Catalog No.
2EP3GAX-IC-2U6T8S23I
2EP3GAX-IC-2U6T8S33I
2EP3GAX-IC-2U6T8S44I
Wt.
28 lbs.
28 lbs.
28 lbs.
ADF110370
2013-03-26 16:25:48
Download