Metalux D ES C R IPTION The Paralux III Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a nominal 3" deep precision cell louver into a 4-3/4" deep para-contoured fixture housing. This combination creates a total high performance parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. Catalog # 2EP3-IC is designed for installations when the housing will be in direct contact with insulation. The high performance luminaire is designed to offer maximum efficiency and performance for today’s unique interior specifications. Prepared by Type Project Date Comments SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching 4-3/4" deep, para-contoured housing, die formed of code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Contoured ballast/ wireway cover is easily removed. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy gauge end plates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed for Type IC Recessed Luminaire (Rated for direct contact with insulation) Suitable for damp locations. Positive spring loaded, self locking, steel latches. Safety lock T-hinges allow hinging and latching from either side. Louver Die formed of low iridescent, vertical grain anodized aluminum. Finish is Anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. 2EP3GAX-IC 2U6T8 6, 9, 16 Cell 2' X 2' PARABOLIC 2-U LAMPS SEMI-SPECULAR, SPECULAR OR WHITE PAINTED LOUVER 4-3/4" [121mm] Paralux III Recessed Static or Air Supply Troffer For Use in Insulated Ceilings 23-3/4" [603mm] MO UNTING D A TA 2 LAMP 7/8" [22mm] K.O. (2) L A MP CONF IGURA T IONS Access Plate 7/8" [22mm] K.O. (2) 2 LAMP – 6 CELL 4-3/4" [121mm] ENERGY DATA 4-5/8" 2-5/8" X X [117mm] [67mm] X=6" 23-3/4" [603mm] [152mm] 2 LAMP – 9 CELL 23-3/4" [603mm] Input Watts: EB Ballast & STD Lamps 2U6T8 (61) 4-3/4" [121mm] 3-5/8" [93mm] 1-3/4" [45mm] 6-7/8" [176mm] 24" [608mm] 2-5/8" [67mm] X=6" [152mm] X 4-5/8" [117mm] Luminaire Efficacy Rating LER = FP-52 Catalog Number: 2EP3GAX-IC-2U6T8 X 23-3/4" [603mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.62 **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. CEI LING C OM PA TIB I L I T Y G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. (Verify compatibility/ consult factory.) C ER TEM S YS D G Concealed T S G Grid/Lay-in Standard TIFIE ADF110370 2013-03-26 16:25:48 2E P 3 GAX-IC -2 U6 T 8 PH OTOM ETR IC S Coefficients of Utilization 2EP3GAX-IC-2U6T8S23I Electronic Ballast FB31T8/35K/6 Lamps 2600 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 63.8% Test Report: 2EP3GAXIC2U6T8S23I.IES rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 76 71 65 60 55 51 47 43 40 38 35 76 68 60 54 48 43 39 35 32 29 27 76 66 57 49 43 38 33 30 27 24 22 76 64 53 45 39 34 29 26 23 21 19 74 69 63 58 53 49 46 42 39 37 35 74 67 59 53 47 42 38 35 32 29 27 74 65 56 48 42 37 33 30 27 24 22 74 63 53 45 39 33 29 26 23 21 19 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 71 64 57 51 45 41 37 34 31 28 26 68 62 55 49 44 40 36 33 30 28 26 65 59 53 48 43 39 35 32 29 27 25 64 56 48 41 36 31 27 24 22 20 18 71 62 54 47 41 36 32 29 26 24 22 71 61 52 44 38 33 29 26 23 21 19 68 60 53 46 40 36 32 29 26 24 22 68 59 51 43 38 33 29 26 23 21 19 Zonal Lumen Summary Typical VCP Percentages Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens %Lamp %Fixture 1067 1717 2984 3317 3317 20.5 33.0 57.4 63.8 63.8 32.2 51.8 90.0 100.0 100.0 Height Along 8.5’ 10.0’ 72 67 79 73 83 78 82 78 85 82 65 58 51 45 40 35 31 28 26 23 21 65 57 49 43 37 32 29 25 23 21 19 Height Across 8.5’ 10.0’ 65 60 75 69 79 74 78 73 82 78 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Across ⊥ 1314 1319 1338 1371 1383 1330 1174 Along II 1314 1303 1274 1234 1188 1129 1066 45° 1314 1311 1304 1300 1293 1266 1210 990 1089 998 909 812 708 586 422 204 65 21 7 4 0 920 773 698 647 547 327 102 25 9 4 0 902 880 924 950 754 327 100 26 10 4 0 LER = FP-52 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.62 ORDER IN G INFOR M A TION SAMPLE NUMBER: 2EP3GAX-IC-3BX4036-MI-120V-EB51-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' Width EP=Paralux Louver Voltage (4) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (5) Number of Lamps 2=2 Lamps 3=3 Lamps (3) Wattage (Length) BX40=40W Biax (24") U6T8=32W T8 (24") U15/8=31W T8 (24") Louver Color/Type ST=Silver Tannenbaum Cell Configuration 36=3 Rows of 6, 18 Cell 3=3" Louver Depth Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (7) F=Aluminum Flange Trim (8) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Louver Finish MI=Specular/Mirrored (Low Iridescent) (Silver Only) Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps=Lamps Installed (refer to lamp ordering options) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (6) Option – Aluminum Flange Trim (8) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB5 =T5 Biax Electronic Instant Start (9) Total Harmonic Distortion < 20% No. of Ballast 1, 2 or 3 TEB5 =T5 Biax Electronic Instant Start (9) Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 ER5 =T5 Biax Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) IC=IC Rated (1) (2) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per (3) (4) (5) fixture. Standard off-center ballast on 3-lamp fixtures. Products also available in non-US voltages and frequencies for international markets. Not avail(6) able when specifying emergencies, voltage must be specific. Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, (7) (8) must use low profile battery pack. Louver is recessed by 5/16" in Concealed T or Slot Grid T. Specify row configuration, type in catalog number when (9) ordering complete fixture. Not available in UNV voltages. Must specify voltage. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. SH IP P ING D A T A Catalog No. 2EP3GAX-IC-2U6T8S23I 2EP3GAX-IC-2U6T8S33I 2EP3GAX-IC-2U6T8S44I Wt. 28 lbs. 28 lbs. 28 lbs. ADF110370 2013-03-26 16:25:48