Metalux

advertisement
Metalux
D ES C R IPTION
The Paralux IV Series features recessed aesthetics and the latest in
energy efficient technology. The luminaire incorporates a 4" precision
cell louver into a 6-3/4" deep para-contoured fixture housing. This
combination creates a high comfort parabolic optical assembly for
optimum performance. The series is compatible with all of today’s
popular ceiling systems and is available with a number of options and
accessories for application versatility. The high comfort luminaire is
designed to provide a superior visual environment plus the higher
shielding louver angle offers excellent cut-off for today‘s lighting
requirements. The Paralux IV series is an excellent choice for commercial
spaces, schools, hospitals or retail merchandising areas.
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
C on s t r u c t i o n
6-3/4" deep, para-contoured
housing, die formed code gauge,
prime cold rolled steel. Die
embossed housing has full length
die formed stiffeners for added
strength. Deep “V” ballast/wireway
cover easily removed without tools.
Die formed captive lampholder
bracket fully encloses lampholder
wiring permitting easy lampholder
replacement. Heavy end plates,
securely attached with interlocking
tabs and screws. Four auxiliary
fixture end suspension points
provided. KOs for continuous
row wiring. End plates have labor
saving integral Grid-Lock feature
for safety and convenience.
Housing features enable fixture to
be converted from Grid to T-option
or vice versa in the field.*
H inging/Latching
Positive cam action spring loaded,
self locking, black steel latches.
Safety lock T-hinges allow hinging
and latching either side.
E le ctrica l* *
Ballast are CBM/ETL Class "P" and
are positively secured by mounting
bolts. Pressure lock lampholders.
UL/CUL listed. Suitable for damp
locations.
F in ish
Lighting grade, baked white
enamel finish. Multistage, iron
phosphate pretreatment ensures
maximum bonding and rust
inhibition.
Louver
Die formed of semi-specular,
vertical grain, aluminum. Finish
is anodic oxide coating. Accurate
precision parabolic cells are held
in place with interlocking feature.
True-cut mitered corners. Black
reveal with integral mechanical
light seal around entire perimeter
of louver. Louver protected from
construction contaminants by
polyethylene cover.
2 P GAX
2U6T8
6, 9, 12, 16 Cell
2' X 2' PARABOLIC
2-U LAMPS
SEMI-SPECULAR LOUVER
ADF090547
2015-10-13 16:55:01
6-3/4"
[172mm]
Paralux IV
Recessed Air Supply Troffer
23-3/4"
[603mm]
MO UNTING D A TA
2 LAMP
7/8" [22mm]
K.O. (2)
L AM P C O N FIGURA T IONS
Access Plate
7/8" [22mm] K.O. (2)
2 LAMP – 6 CELL
6-3/4"
[172mm]
6-3/4"
[172mm]
4"
[102mm]
X=6"
[152mm]
23-3/4"
[603mm]
ENERGY DATA
2 LAMP – 16 CELL
X
4-5/8"
[117mm]
X
23-3/4" [603mm]
4"
[102mm]
X=6"
[152mm]
X
4-5/8"
[117mm]
X
23-3/4" [603mm]
2 LAMP – 9/12 CELL
3-5/8" [93mm]
1-3/4" [45mm]
4"
[102mm]
X=6"
[152mm]
CE ILING C OM PA TA B I L I T Y
G
Concealed T
Luminaire Efficacy Rating
LER = FP-49
Catalog Number: 2PGAX-2U6T8
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $4.90
6-7/8" [176mm]
24" [608mm]
G
Grid/Lay-in
Standard
6-3/4"
[172mm]
Input Watts:
EB Ballast & STD Lamps
2U6T8 (61)
G
Slot Grid
X
4-5/8"
[117mm]
X
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
23-3/4" [603mm]
F
Aluminum Flange Trim
With Supporting
Swing Gates
MZ
Modular Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
Concealed “T” or ”Z“
Metal Pan
G
G
G
F
MZ
MZ
(Verify compatibility/ consult
factory.)
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF090545
2015-10-20 15:04:17
PH OTOM ETR IC S
Candlepower
2PGAX-2U6T8S33I
Electronic Ballast
FB31T8/TL741/6
Lamps
2600 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.1 x
mounting height
Efficiency 61.3%
Test Report:
2PGX2U6T8S33I.IES
LER = FP-49
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.90
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1496
1478
1438
1390
1331
1257
1177
1088
984
870
734
571
303
98
37
19
8
5
0
Across ⊥
1496
1496
1473
1432
1375
1274
1171
1122
1111
1080
1009
880
467
159
64
30
12
0
0
45°
1496
1490
1463
1409
1344
1264
1158
1032
927
866
793
650
373
107
44
21
10
2
0
73
66
60
54
49
44
40
36
32
29
26
73
64
57
50
50
39
35
31
27
24
21
73
63
54
47
47
36
31
27
24
21
18
71
67
62
58
54
49
46
42
39
36
33
71
65
59
53
48
43
39
35
31
28
26
71
63
56
50
44
39
34
31
27
24
21
71
62
53
47
41
35
31
27
24
21
18
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
0-180
Lumens
1119
1789
3063
3246
3246
%Lamp
21.1
33.8
57.8
61.3
61.3
FB31T8/TL741/6
Lamps
2600 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.2 x
mounting height
Efficiency 54.4%
Test Report:
2PGX2U6T8S44I.IES
LER = FP-43
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $5.52
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1528
1511
1463
1404
1342
1267
1178
1076
963
820
621
374
130
49
26
15
8
3
0
Across ⊥
1528
1590
1590
1638
1632
1520
1296
1063
871
747
643
449
146
59
29
16
6
2
0
45°
1528
1530
1530
1531
1514
1459
1341
1140
895
687
525
325
110
47
24
14
7
1
0
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
73
68
64
59
55
51
47
43
40
36
34
Candlepower
2PGAX-2U6T8S44I
Electronic Ballast
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
2 P GAX-2 U6 T 8
P H OT OME T RICS
%Fixture
34.5
55.1
94.4
100.0
100.0
20%
50%
50 30 10
30%
50 30 10
50
68
62
57
52
47
42
38
34
31
28
25
65
60
55
50
45
41
37
33
30
27
25
63
58
53
49
44
40
36
33
29
26
24
68
61
54
48
43
38
34
30
26
23
21
68
60
52
46
40
35
31
27
24
20
18
65
59
53
47
42
37
33
30
26
23
21
65
58
51
45
40
35
31
27
23
20
18
10%
30 10
63
57
52
46
41
37
33
29
26
23
20
63
56
50
44
39
34
30
27
23
20
18
0%
0
61
55
49
43
38
33
29
26
22
19
17
Ty p i c a l VC P Pe r c e n t a g e s
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Height Along
8.5’
10.0’
82
76
87
81
89
84
89
85
90
87
Height Across
8.5’
10.0’
76
69
83
76
85
81
85
81
87
84
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
65
61
57
54
50
47
44
40
37
35
32
65
59
54
49
45
41
38
34
31
28
26
65
58
52
46
42
37
34
30
27
24
22
65
56
50
44
39
34
31
28
24
21
19
63
60
56
53
49
46
43
40
37
34
32
63
58
53
49
45
41
37
34
31
28
25
63
57
51
46
41
37
33
30
27
24
22
63
55
49
43
39
34
31
27
24
21
19
20%
50%
50 30 10
30%
50 30 10
50
60
56
51
46
43
40
36
33
30
27
25
58
54
50
46
42
39
35
32
29
27
24
55
52
48
45
41
38
35
32
29
26
24
60
55
50
44
40
36
33
30
27
24
21
60
54
48
43
38
34
31
27
24
21
19
58
53
48
44
40
36
32
29
26
23
21
58
52
47
42
38
34
30
27
24
21
19
Zonal Lumen Summary
Ty p i c a l VC P Pe r c e n t a g e s
Zone
0-30
0-40
0-60
0-90
0-180
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Lumens
1227
1916
2805
2881
2881
%Lamp
23.2
36.2
52.9
54.4
54.4
%Fixture
42.6
66.5
97.4
100.0
100.0
10%
30 10
55
51
47
43
39
35
32
29
26
23
21
Height Along
8.5’
10.0’
92
88
94
91
95
92
94
92
95
93
55
51
46
41
37
33
30
27
24
21
19
0%
0
54
50
45
40
36
32
29
26
23
20
18
Height Across
8.5’
10.0’
91
87
93
90
94
92
94
91
94
93
ORDER IN G INFOR M A TION
SAMPLE NUMBER: 2PGAX-2U6T8S33I-UNV-EB81-U
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
Number
of Lamps
2=2 Lamps
HR=Heat
Removal (1)
Louver Color
S=Silver
W=White
Width
2=2' width
P=Paralux IV
Trim Type
G=Grid/Lay-in (Standard)
G=Concealed T/Slot Grid (6)
F=Aluminum Flange Trim (7)
MZ=Modular Trim
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver
with Directional Air Vane (Add V)
Voltage (3)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (4)
Wattage (Length)
U6T8=32W T8 (24")
Cell Configuration
23=2 Rows of 3, 6 Cell (2' x 2')
33=3 Rows of 3, 9 Cell (2' x 2')
34=3 Rows of 4, 12 Cell (2' x 2')
44=4 Rows of 4, 16 Cell (2' x 2')
Louver Finish
I=Semi-Specular/Haze (Low Iridescent)
Standard
MI=Specular/Mirrored (Low Iridescent)
P=Painted
Options
GL=Single Element Fuse
GM=Double Element Fuse
WTR=White Reveal
Lamps=Lamps Installed
(refer to lamp ordering
options)
Flex=Flex Installed
(Reference Flex ordering
information)
EL=Emergency Installed (5)
Ballast Type
EB8 =T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 /PLUS= T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of
High Ballast Factor >1.15
Ballast
1, 2 or 3
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
Option – Aluminum Flange Trim (7)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
(1)
(2)
NOTES: Integral End Plate Grid Lock feature not available in Heat Removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per
(3)
(4)
fixture. Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be
(5)
(6)
specific. Fixtures equipped with “EL” option may require a 7-1/2" housing depth. If installing in field, must use low profile battery pack. Louver is recessed by
(7)
5/16" in Concealed T or Slot Grid T. Specify row configuration, type in catalog number when ordering complete fixture.
Options
PAF=Painted After
Fabrication
REP=Riveted
Endplates
Packaging
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
ACCESSORIES
EQ-CLIP-U=T-BAR Safety Earthquake Clips(2)
SH IP P ING D A T A
Catalog No.
2PGAX-2U6T8S33I
2PGAX-2U6T8S23I
2PGAX-2U6T8S34I
2PGAX-2U6T8S44I
Wt.
29 lbs.
29 lbs.
29 lbs.
29 lbs.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper
Lighting Representative for availability and ordering information.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADF090545
2015-10-20 15:04:17
Download