Metalux D ES C R IPTION The Paralux IV Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 4" precision cell louver into a 6-3/4" deep para-contoured fixture housing. This combination creates a high comfort parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The high comfort luminaire is designed to provide a superior visual environment plus the higher shielding louver angle offers excellent cut-off for today‘s lighting requirements. The Paralux IV series is an excellent choice for commercial spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n 6-3/4" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Deep “V” ballast/wireway cover easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have labor saving integral Grid-Lock feature for safety and convenience. Housing features enable fixture to be converted from Grid to T-option or vice versa in the field.* H inging/Latching Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. E le ctrica l* * Ballast are CBM/ETL Class "P" and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Louver Die formed of semi-specular, vertical grain, aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. 2 P GAX 2U6T8 6, 9, 12, 16 Cell 2' X 2' PARABOLIC 2-U LAMPS SEMI-SPECULAR LOUVER ADF090547 2015-10-13 16:55:01 6-3/4" [172mm] Paralux IV Recessed Air Supply Troffer 23-3/4" [603mm] MO UNTING D A TA 2 LAMP 7/8" [22mm] K.O. (2) L AM P C O N FIGURA T IONS Access Plate 7/8" [22mm] K.O. (2) 2 LAMP – 6 CELL 6-3/4" [172mm] 6-3/4" [172mm] 4" [102mm] X=6" [152mm] 23-3/4" [603mm] ENERGY DATA 2 LAMP – 16 CELL X 4-5/8" [117mm] X 23-3/4" [603mm] 4" [102mm] X=6" [152mm] X 4-5/8" [117mm] X 23-3/4" [603mm] 2 LAMP – 9/12 CELL 3-5/8" [93mm] 1-3/4" [45mm] 4" [102mm] X=6" [152mm] CE ILING C OM PA TA B I L I T Y G Concealed T Luminaire Efficacy Rating LER = FP-49 Catalog Number: 2PGAX-2U6T8 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.90 6-7/8" [176mm] 24" [608mm] G Grid/Lay-in Standard 6-3/4" [172mm] Input Watts: EB Ballast & STD Lamps 2U6T8 (61) G Slot Grid X 4-5/8" [117mm] X **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 23-3/4" [603mm] F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ (Verify compatibility/ consult factory.) LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF090545 2015-10-20 15:04:17 PH OTOM ETR IC S Candlepower 2PGAX-2U6T8S33I Electronic Ballast FB31T8/TL741/6 Lamps 2600 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.1 x mounting height Efficiency 61.3% Test Report: 2PGX2U6T8S33I.IES LER = FP-49 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.90 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1496 1478 1438 1390 1331 1257 1177 1088 984 870 734 571 303 98 37 19 8 5 0 Across ⊥ 1496 1496 1473 1432 1375 1274 1171 1122 1111 1080 1009 880 467 159 64 30 12 0 0 45° 1496 1490 1463 1409 1344 1264 1158 1032 927 866 793 650 373 107 44 21 10 2 0 73 66 60 54 49 44 40 36 32 29 26 73 64 57 50 50 39 35 31 27 24 21 73 63 54 47 47 36 31 27 24 21 18 71 67 62 58 54 49 46 42 39 36 33 71 65 59 53 48 43 39 35 31 28 26 71 63 56 50 44 39 34 31 27 24 21 71 62 53 47 41 35 31 27 24 21 18 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 1119 1789 3063 3246 3246 %Lamp 21.1 33.8 57.8 61.3 61.3 FB31T8/TL741/6 Lamps 2600 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.2 x mounting height Efficiency 54.4% Test Report: 2PGX2U6T8S44I.IES LER = FP-43 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $5.52 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1528 1511 1463 1404 1342 1267 1178 1076 963 820 621 374 130 49 26 15 8 3 0 Across ⊥ 1528 1590 1590 1638 1632 1520 1296 1063 871 747 643 449 146 59 29 16 6 2 0 45° 1528 1530 1530 1531 1514 1459 1341 1140 895 687 525 325 110 47 24 14 7 1 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 73 68 64 59 55 51 47 43 40 36 34 Candlepower 2PGAX-2U6T8S44I Electronic Ballast Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 2 P GAX-2 U6 T 8 P H OT OME T RICS %Fixture 34.5 55.1 94.4 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 68 62 57 52 47 42 38 34 31 28 25 65 60 55 50 45 41 37 33 30 27 25 63 58 53 49 44 40 36 33 29 26 24 68 61 54 48 43 38 34 30 26 23 21 68 60 52 46 40 35 31 27 24 20 18 65 59 53 47 42 37 33 30 26 23 21 65 58 51 45 40 35 31 27 23 20 18 10% 30 10 63 57 52 46 41 37 33 29 26 23 20 63 56 50 44 39 34 30 27 23 20 18 0% 0 61 55 49 43 38 33 29 26 22 19 17 Ty p i c a l VC P Pe r c e n t a g e s Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 82 76 87 81 89 84 89 85 90 87 Height Across 8.5’ 10.0’ 76 69 83 76 85 81 85 81 87 84 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 65 61 57 54 50 47 44 40 37 35 32 65 59 54 49 45 41 38 34 31 28 26 65 58 52 46 42 37 34 30 27 24 22 65 56 50 44 39 34 31 28 24 21 19 63 60 56 53 49 46 43 40 37 34 32 63 58 53 49 45 41 37 34 31 28 25 63 57 51 46 41 37 33 30 27 24 22 63 55 49 43 39 34 31 27 24 21 19 20% 50% 50 30 10 30% 50 30 10 50 60 56 51 46 43 40 36 33 30 27 25 58 54 50 46 42 39 35 32 29 27 24 55 52 48 45 41 38 35 32 29 26 24 60 55 50 44 40 36 33 30 27 24 21 60 54 48 43 38 34 31 27 24 21 19 58 53 48 44 40 36 32 29 26 23 21 58 52 47 42 38 34 30 27 24 21 19 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 1227 1916 2805 2881 2881 %Lamp 23.2 36.2 52.9 54.4 54.4 %Fixture 42.6 66.5 97.4 100.0 100.0 10% 30 10 55 51 47 43 39 35 32 29 26 23 21 Height Along 8.5’ 10.0’ 92 88 94 91 95 92 94 92 95 93 55 51 46 41 37 33 30 27 24 21 19 0% 0 54 50 45 40 36 32 29 26 23 20 18 Height Across 8.5’ 10.0’ 91 87 93 90 94 92 94 91 94 93 ORDER IN G INFOR M A TION SAMPLE NUMBER: 2PGAX-2U6T8S33I-UNV-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated Number of Lamps 2=2 Lamps HR=Heat Removal (1) Louver Color S=Silver W=White Width 2=2' width P=Paralux IV Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (6) F=Aluminum Flange Trim (7) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Wattage (Length) U6T8=32W T8 (24") Cell Configuration 23=2 Rows of 3, 6 Cell (2' x 2') 33=3 Rows of 3, 9 Cell (2' x 2') 34=3 Rows of 4, 12 Cell (2' x 2') 44=4 Rows of 4, 16 Cell (2' x 2') Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps=Lamps Installed (refer to lamp ordering options) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (5) Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 Option – Aluminum Flange Trim (7) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row (1) (2) NOTES: Integral End Plate Grid Lock feature not available in Heat Removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per (3) (4) fixture. Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be (5) (6) specific. Fixtures equipped with “EL” option may require a 7-1/2" housing depth. If installing in field, must use low profile battery pack. Louver is recessed by (7) 5/16" in Concealed T or Slot Grid T. Specify row configuration, type in catalog number when ordering complete fixture. Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) SH IP P ING D A T A Catalog No. 2PGAX-2U6T8S33I 2PGAX-2U6T8S23I 2PGAX-2U6T8S34I 2PGAX-2U6T8S44I Wt. 29 lbs. 29 lbs. 29 lbs. 29 lbs. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADF090545 2015-10-20 15:04:17