Metalux

advertisement
Metalux
D ES C R IPTION
The Paralux II Series features recessed aesthetics and the latest in energy
efficient technology. The luminaire incorporates a 2" precision cell louver
into a 4-3/4" deep para-contoured fixture housing. This combination
creates a total low profile parabolic optical assembly for optimum
performance. The series is compatible with all of today’s popular ceiling
systems and is available with a number of options and accessories for
application versatility. The low profile luminaire is designed to offer
the market-place a parabolic choice when economics and shallow
plenum space are factors. The Paralux II series is an excellent choice
for commercial office spaces, schools, hospitals or retail merchandising
areas.
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
C on s t r u c t i o n
E le ctrica l* *
H inging/Latching
4-3/4" deep, para-contoured
housing, die formed code gauge,
prime cold rolled steel. Full length
die formed stiffeners for added
strength. Contoured ballast/
wireway cover, easily removed
without tools. Die formed captive
lampholder bracket fully encloses
lampholder wiring permitting easy
lampholder replacement. Heavy
end plates, securely attached with
interlocking tabs and screws. Four
auxiliary fixture end suspension
points provided. KOs for
continuous row wiring. End plates
have integral Grid-Lock feature for
safety and convenience.
Ballasts are CBM/ETL Class “P” and
are positively secured by mounting
bolts. Pressure lock lampholders.
UL/CUL listed. Suitable for damp
locations.
Positive cam action spring loaded,
self locking, black steel latches.
Safety lock T-hinges allow hinging
and latching either side.
Louver
F in ish
Lighting grade, baked white
enamel finish. Multistage, iron
phosphate pretreatment ensures
maximum bonding and rust
inhibition.
Die formed of semi-specular
aluminum. Finish is anodic oxide
coating. Accurate precision
parabolic cells are held in place
by interlocking feature. True-cut
mitered corners. Black reveal
with mechanical light seal around
entire perimeter of louver. Louver
protected by polyethylene cover.
4-3/4"
[121mm]
2P2GAX
228T5
428T5
254T5
454T5
12, 16, 24 or 32
Cell
2' X 4' PARABOLIC
2 OR 4 T5 LAMP
SEMI-SPECULAR LOUVER
23-3/4"
[603mm]
Paralux II
Recessed Air Supply Troffer
MO UNTING D A TA
2/4 LAMP
L A MP CONF IGURA T IONS
Access Plate
7/8" [22mm]
7/8" [22mm] K.O. (2)
2 LAMP – 12/16 CELL
4-3/4"
[121mm]
2"
[51mm]
10-3/16"
[259mm]
23-3/4" [603mm]
23-3/4"
[603mm]
ENERGY DATA
4 LAMP – 24/32 CELL
4-3/4"
[121mm]
2"
[51mm]
X=4-3/4"
[121mm]
4-5/8" [119mm]
3" [77mm]
48" [1217mm]
7-7/8" [201mm]
Input Watts:
EB Ballast & STD Lamps
228T5 (72), 428T5 (144),
254T5 (120), 454T5 (238)
X
X
5-3/4"
[146mm]
23-3/4" [603mm]
CEI LING C OM PA TIB I L I T Y
G
Grid/Lay-in
Standard
G
Concealed T
G
Slot Grid
F
Aluminum Flange Trim
With Supporting
Swing Gates
MZ
Modular Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
Concealed “T” or ”Z“
Metal Pan
G
G
G
F
MZ
MZ
(Verify compatibility/ consult
factory.)
Luminaire Efficacy Rating
LER = FP-56
Catalog Number: 2P2GAX-228T5S26I
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $4.31
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements."
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF090237
2015-10-13 15:35:05
2P 2 GAX 2 OR 4 L T 5
PH OTOM ETR IC S
Candlepower
2P2GAX-228T5S26I
Electronic Ballast
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
F28T5 Lamps
2600 Lumens
Spacing criterion:
(II) 1.3 x mounting
height, (⊥) 1.7 x
mounting height
Efficiency 77.1%
Test Report:
220P226
LER = FP-56
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.31
Along II
1361
1364
1351
1323
1282
1230
1164
1085
995
894
780
653
502
332
167
47
15
4
0
Across ⊥
1361
1382
1390
1378
1369
1368
1370
1393
1516
1489
1231
996
559
270
168
85
15
5
0
45°
1361
1372
1377
1363
1329
1293
1255
1214
1170
1143
1092
915
680
460
173
67
19
6
0
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
92
82
72
64
57
51
45
41
37
34
31
92
79
67
58
50
44
39
34
31
28
25
92
76
63
53
45
39
34
30
26
24
21
90
83
76
69
64
58
54
50
46
43
41
90
80
71
63
56
50
45
40
37
34
31
90
78
66
57
50
43
38
34
31
28
25
90
75
63
53
45
39
34
30
26
24
21
50%
50 30 10
30%
50 30 10
50
86
77
68
60
54
48
43
39
36
33
30
82
74
66
58
52
47
42
38
35
32
30
79
71
63
56
50
45
41
37
34
31
29
86
75
64
56
48
43
38
34
30
27
25
86
73
61
52
44
38
33
29
26
23
21
82
72
63
54
47
42
37
33
30
27
25
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
%Lamp
21.4
36.3
68.2
77.1
77.1
Spacing criterion:
(II) 1.3 x mounting
height, (⊥) 1.7 x
mounting height
Efficiency 73.0%
Test Report:
220P227
LER = FPYearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $
20%
Zonal Lumen Summary
Lumens
1115
1887
3549
4010
4010
F54T5 Lamps
4400 Lumens
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
2181
2184
2164
2116
2052
1968
1865
1743
1604
1449
1269
1067
824
543
271
73
24
7
0
Across ⊥
2181
2214
2225
2206
2190
2189
2192
2229
2420
2377
1965
1593
885
430
263
137
23
8
0
45°
2181
2199
2207
2181
2126
2066
2006
1941
1871
1831
1751
1469
1092
737
271
105
28
9
0
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
92
85
78
71
65
60
55
51
48
44
42
Candlepower
2P2GAX-254T5S26I
Electronic Ballast
%Fixture
27.8
47.1
88.5
100.0
100.0
Average
0-Deg
cd/sm
2124
1912
1319
305
77
82
71
60
51
44
38
33
29
26
23
21
10%
30 10
79
70
61
53
46
41
36
33
29
27
24
Average
45-Deg
cd/sm
2715
2679
1828
435
116
79
69
59
50
43
38
33
29
26
23
21
0%
0
77
67
57
49
42
36
31
28
24
22
20
Average
90-Deg
cd/sm
3537
2917
1073
552
96
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
87
81
74
68
62
57
52
49
45
42
39
87
78
68
60
54
48
43
39
35
32
30
87
75
64
55
48
42
37
33
29
26
24
87
72
60
50
43
37
32
28
25
22
20
85
79
72
66
60
55
51
47
44
41
38
85
76
67
59
53
47
42
38
35
32
29
85
73
63
54
47
41
36
32
29
26
24
85
71
59
50
43
37
32
28
25
22
20
20%
50%
50 30 10
30%
50 30 10
50
81
73
65
57
51
46
41
37
34
31
29
78
70
62
55
49
44
40
36
33
30
28
75
67
60
53
48
43
39
35
32
30
27
81
71
61
53
46
40
36
32
29
26
24
81
69
58
49
42
36
32
28
25
22
20
78
68
59
51
45
40
35
31
28
26
23
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
1785
3020
5689
6427
6427
%Lamp
20.3
34.3
64.6
73.0
73.0
%Fixture
27.8
47.0
88.5
100.0
100.0
78
67
57
48
41
36
31
28
25
22
20
Average
0-Deg
cd/sm
3528
3203
2212
486
85
10%
30 10
75
66
58
50
44
39
34
31
28
25
23
75
65
56
48
41
36
31
28
25
22
20
Average
45-Deg
cd/sm
4458
4409
3002
698
178
0%
0
73
64
54
46
39
34
30
26
23
21
19
Average
90-Deg
cd/sm
5787
4781
1752
911
158
ORDER IN G INFOR M A TION
S A M P L E N U M B E R : 2 P 2 G A X - 2 2 8 T 5 S 2 6 I - U N V- E B T 1 - U
Rating
Blank=
Standard
NY=New York
Rated
ATW-SW4=
Chicago
Rated
HR=Heat
Removal (1)
Width
2=2' Width
P=Paralux Louver
2=2' Louver Depth
Trim Type
G=Grid/Lay-in (Standard)
G or T=Concealed T (8)
G or T=Slot Grid (2), (8)
F=Aluminum Flange Trim (6)
MZ=Modular Trim
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver
with Directional Air Vane (Add V)
Voltage (3)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage
120-277 (4)
Number
of Lamps
2 or 4 lamps
Wattage (Length)
28T5=28W T5 (48")
54T5=54W T5HO (48")
Options
GL=Single Element Fuse
GM=Double Element Fuse
WTR=White Reveal
Flex=Flex Installed (Reference
Flex ordering information)
EL=Emergency Installed (7)
Cell Configuration
26=2 Rows of 6, 12 Cell (2' x 4')
28=2 Rows of 8, 16 Cell (2' x 4')
46=4 Rows of 6, 24 Cell (2' x 4')
48=4 Rows of 8, 32 Cell (2' x 4')
Louver Finish
I=Semi-Specular/Haze (Low Iridescent)
Standard
MI=Specular/Mirrored (Low Iridescent)
P=Painted
Ballast Type (4)
EBT
No. of Ballast
1 or 2
ACCESSORIES
EQ-CLIP-U=T-BAR Safety
Earthquake Clips(2)
Ballast Factor/Type
(For 28W T5 Lamp Only)
N=Normal Light Output .95 BF
H=High Light Output 1.15 BF
NDIM=Normal .95-1.0 BF Step Dimming (5)
HDIM=High 1.15 BF Step Dimming (5)
(2)
NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.
(3)
(4)
(5)
Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific. .95
(6)
(7)
and 1.15 ballast factor available for 28W T5 lamps only. Specify row configuration, type in catalog number when ordering complete fixture. Fixtures equipped with
(8)
“EL” option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. G: Louver is recessed by 5/16" in Concealed T or Slot Grid.
T: Housing depth= 4-1/2"
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
Specifications and
dimensions subject to
change without notice.
(Additional options available. See Accessory
Section)
=T5/T5HO Linear Electronic
Program Rapid Start
Total Harmonic
Distortion < 10%
Option – Aluminum Flange Trim (6)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
20GA/REP=20 Gauge
Riveted Endplates. For
use in New York City.
Lamps Installed
Blank=No Lamps Installed
L5835=T5 Lamp, 3500K
L5841=T5 Lamp, 4100K
Louver Color
S=Silver
W=White
(1)
Options
PAF=Painted
After Fabrication
Packaging
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
SH IP P ING D A T A
Catalog No.
2P2GAX-228T5S26I
2P2GAX-254T5S26I
2P2GAX-228T5S28I
2P2GAX-254T5S28I
2P2GAX-428T5S46I
2P2GAX-454T5S46I
2P2GAX-428T5S48I
2P2GAX-454T5S48I
Wt.
42 lbs.
42 lbs.
42 lbs.
42 lbs.
42 lbs.
42 lbs.
42 lbs.
42 lbs.
ADF090237
2015-10-13 15:35:05
Download