Metalux D ES C R IPTION The Paralux II Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 2" precision cell louver into a 4-3/4" deep para-contoured fixture housing. This combination creates a total low profile parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The low profile luminaire is designed to offer the market-place a parabolic choice when economics and shallow plenum space are factors. The Paralux II series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching 4-3/4" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Full length die formed stiffeners for added strength. Contoured ballast/ wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. Louver F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Die formed of semi-specular aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place by interlocking feature. True-cut mitered corners. Black reveal with mechanical light seal around entire perimeter of louver. Louver protected by polyethylene cover. 4-3/4" [121mm] 2P2GAX 228T5 428T5 254T5 454T5 12, 16, 24 or 32 Cell 2' X 4' PARABOLIC 2 OR 4 T5 LAMP SEMI-SPECULAR LOUVER 23-3/4" [603mm] Paralux II Recessed Air Supply Troffer MO UNTING D A TA 2/4 LAMP L A MP CONF IGURA T IONS Access Plate 7/8" [22mm] 7/8" [22mm] K.O. (2) 2 LAMP – 12/16 CELL 4-3/4" [121mm] 2" [51mm] 10-3/16" [259mm] 23-3/4" [603mm] 23-3/4" [603mm] ENERGY DATA 4 LAMP – 24/32 CELL 4-3/4" [121mm] 2" [51mm] X=4-3/4" [121mm] 4-5/8" [119mm] 3" [77mm] 48" [1217mm] 7-7/8" [201mm] Input Watts: EB Ballast & STD Lamps 228T5 (72), 428T5 (144), 254T5 (120), 454T5 (238) X X 5-3/4" [146mm] 23-3/4" [603mm] CEI LING C OM PA TIB I L I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ (Verify compatibility/ consult factory.) Luminaire Efficacy Rating LER = FP-56 Catalog Number: 2P2GAX-228T5S26I Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.31 **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements." LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF090237 2015-10-13 15:35:05 2P 2 GAX 2 OR 4 L T 5 PH OTOM ETR IC S Candlepower 2P2GAX-228T5S26I Electronic Ballast Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 F28T5 Lamps 2600 Lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.7 x mounting height Efficiency 77.1% Test Report: 220P226 LER = FP-56 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.31 Along II 1361 1364 1351 1323 1282 1230 1164 1085 995 894 780 653 502 332 167 47 15 4 0 Across ⊥ 1361 1382 1390 1378 1369 1368 1370 1393 1516 1489 1231 996 559 270 168 85 15 5 0 45° 1361 1372 1377 1363 1329 1293 1255 1214 1170 1143 1092 915 680 460 173 67 19 6 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 92 82 72 64 57 51 45 41 37 34 31 92 79 67 58 50 44 39 34 31 28 25 92 76 63 53 45 39 34 30 26 24 21 90 83 76 69 64 58 54 50 46 43 41 90 80 71 63 56 50 45 40 37 34 31 90 78 66 57 50 43 38 34 31 28 25 90 75 63 53 45 39 34 30 26 24 21 50% 50 30 10 30% 50 30 10 50 86 77 68 60 54 48 43 39 36 33 30 82 74 66 58 52 47 42 38 35 32 30 79 71 63 56 50 45 41 37 34 31 29 86 75 64 56 48 43 38 34 30 27 25 86 73 61 52 44 38 33 29 26 23 21 82 72 63 54 47 42 37 33 30 27 25 Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 %Lamp 21.4 36.3 68.2 77.1 77.1 Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.7 x mounting height Efficiency 73.0% Test Report: 220P227 LER = FPYearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $ 20% Zonal Lumen Summary Lumens 1115 1887 3549 4010 4010 F54T5 Lamps 4400 Lumens Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2181 2184 2164 2116 2052 1968 1865 1743 1604 1449 1269 1067 824 543 271 73 24 7 0 Across ⊥ 2181 2214 2225 2206 2190 2189 2192 2229 2420 2377 1965 1593 885 430 263 137 23 8 0 45° 2181 2199 2207 2181 2126 2066 2006 1941 1871 1831 1751 1469 1092 737 271 105 28 9 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 92 85 78 71 65 60 55 51 48 44 42 Candlepower 2P2GAX-254T5S26I Electronic Ballast %Fixture 27.8 47.1 88.5 100.0 100.0 Average 0-Deg cd/sm 2124 1912 1319 305 77 82 71 60 51 44 38 33 29 26 23 21 10% 30 10 79 70 61 53 46 41 36 33 29 27 24 Average 45-Deg cd/sm 2715 2679 1828 435 116 79 69 59 50 43 38 33 29 26 23 21 0% 0 77 67 57 49 42 36 31 28 24 22 20 Average 90-Deg cd/sm 3537 2917 1073 552 96 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 87 81 74 68 62 57 52 49 45 42 39 87 78 68 60 54 48 43 39 35 32 30 87 75 64 55 48 42 37 33 29 26 24 87 72 60 50 43 37 32 28 25 22 20 85 79 72 66 60 55 51 47 44 41 38 85 76 67 59 53 47 42 38 35 32 29 85 73 63 54 47 41 36 32 29 26 24 85 71 59 50 43 37 32 28 25 22 20 20% 50% 50 30 10 30% 50 30 10 50 81 73 65 57 51 46 41 37 34 31 29 78 70 62 55 49 44 40 36 33 30 28 75 67 60 53 48 43 39 35 32 30 27 81 71 61 53 46 40 36 32 29 26 24 81 69 58 49 42 36 32 28 25 22 20 78 68 59 51 45 40 35 31 28 26 23 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 1785 3020 5689 6427 6427 %Lamp 20.3 34.3 64.6 73.0 73.0 %Fixture 27.8 47.0 88.5 100.0 100.0 78 67 57 48 41 36 31 28 25 22 20 Average 0-Deg cd/sm 3528 3203 2212 486 85 10% 30 10 75 66 58 50 44 39 34 31 28 25 23 75 65 56 48 41 36 31 28 25 22 20 Average 45-Deg cd/sm 4458 4409 3002 698 178 0% 0 73 64 54 46 39 34 30 26 23 21 19 Average 90-Deg cd/sm 5787 4781 1752 911 158 ORDER IN G INFOR M A TION S A M P L E N U M B E R : 2 P 2 G A X - 2 2 8 T 5 S 2 6 I - U N V- E B T 1 - U Rating Blank= Standard NY=New York Rated ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' Width P=Paralux Louver 2=2' Louver Depth Trim Type G=Grid/Lay-in (Standard) G or T=Concealed T (8) G or T=Slot Grid (2), (8) F=Aluminum Flange Trim (6) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Number of Lamps 2 or 4 lamps Wattage (Length) 28T5=28W T5 (48") 54T5=54W T5HO (48") Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (7) Cell Configuration 26=2 Rows of 6, 12 Cell (2' x 4') 28=2 Rows of 8, 16 Cell (2' x 4') 46=4 Rows of 6, 24 Cell (2' x 4') 48=4 Rows of 8, 32 Cell (2' x 4') Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted Ballast Type (4) EBT No. of Ballast 1 or 2 ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) Ballast Factor/Type (For 28W T5 Lamp Only) N=Normal Light Output .95 BF H=High Light Output 1.15 BF NDIM=Normal .95-1.0 BF Step Dimming (5) HDIM=High 1.15 BF Step Dimming (5) (2) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (3) (4) (5) Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific. .95 (6) (7) and 1.15 ballast factor available for 28W T5 lamps only. Specify row configuration, type in catalog number when ordering complete fixture. Fixtures equipped with (8) “EL” option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. G: Louver is recessed by 5/16" in Concealed T or Slot Grid. T: Housing depth= 4-1/2" For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Specifications and dimensions subject to change without notice. (Additional options available. See Accessory Section) =T5/T5HO Linear Electronic Program Rapid Start Total Harmonic Distortion < 10% Option – Aluminum Flange Trim (6) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting 20GA/REP=20 Gauge Riveted Endplates. For use in New York City. Lamps Installed Blank=No Lamps Installed L5835=T5 Lamp, 3500K L5841=T5 Lamp, 4100K Louver Color S=Silver W=White (1) Options PAF=Painted After Fabrication Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton SH IP P ING D A T A Catalog No. 2P2GAX-228T5S26I 2P2GAX-254T5S26I 2P2GAX-228T5S28I 2P2GAX-254T5S28I 2P2GAX-428T5S46I 2P2GAX-454T5S46I 2P2GAX-428T5S48I 2P2GAX-454T5S48I Wt. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. ADF090237 2015-10-13 15:35:05