Metalux D ES C R IPTION The Paralux II Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 2" precision cell louver into a 4-3/4" deep para-contoured fixture housing. This combination creates a total low profile parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The low profile luminaire is designed to offer the market-place a parabolic choice when economics and shallow plenum space are factors. The Paralux II series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching 4-3/4" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Full length die formed stiffeners for added strength. Contoured ballast/ wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. Louver Die formed of semi-specular aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place by interlocking feature. True-cut mitered corners. Black reveal with mechanical light seal around entire perimeter of louver. Louver protected by polyethylene cover. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. 2P2GAX 2U6T8 6, 9, 16 Cell 4-3/4" [121mm] 2' X 2' PARABOLIC 2 LAMP SEMI-SPECULAR LOUVER Paralux II Recessed Air Supply Troffer 23-3/4" [603mm] MOUNTING D A TA 2/4 LAMP 7/8" [22mm] K.O. (2) L AM P C O N F IGURA T IONS Access Plate 7/8" [22mm] K.O. (2) 2 LAMP – 36 CELL 4-3/4" [121mm] 2" [51mm] X=6" [152mm] 23-3/4" [603mm] 2 LAMP – 6 CELL 4-3/4" [121mm] X 4-5/8" [117mm] 2 LAMP – 9 CELL 3-5/8" [93mm] 6-7/8" [176mm] 24" [608mm] X 4-5/8" [117mm] X 23-3/4" [603mm] ENERGY DATA 2 LAMP – 16 CELL 4-3/4" [121mm] 1-3/4" [45mm] 2" [51mm] X=6" [152mm] X 23-3/4" [603mm] 4-3/4" [121mm] 2" [51mm] X=6" [152mm] X 4-5/8" [117mm] X 23-3/4" [603mm] 2" [51mm] X=6" [152mm] X 4-5/8" [117mm] X 23-3/4" [603mm] C EILING C OM PA TIB IL I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ Input Watts: EB Ballast & STD Lamps 2U6T8 (61) Luminaire Efficacy Rating LER = FP-50 Catalog Number: 2P2GAX-2U6T8S33I Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.77 **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements." LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS (Verify compatibility/ consult factory.) Safe and convenient means of disconnecting power. ADF090415 2015-10-13 15:11:51 2 P 2 GAX-2 U6 T 8 PH OTOM ETR IC S 2P2GAX-2U6T8S33I Electronic Ballast FB32T8/TL735/6 Lamps 2600 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height ⊥ Efficiency 57.5% || Test Report: 2P2GX2U6T8S33I.IES LER = FP-49 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.92 Candlepower Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1508 1498 1475 1438 1388 1324 1250 1163 1064 954 831 692 527 334 154 39 17 8 0 2P2GAX-2U6T8S34I Electronic Ballast Across ⊥ 1508 1507 1501 1481 1435 1378 1304 1201 1135 1102 1060 916 658 384 159 24 10 3 0 45° 1508 1507 1496 1470 1428 1358 1281 1190 1084 964 857 750 600 392 175 47 12 4 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 85 77 69 62 55 49 44 40 36 32 29 85 75 65 57 50 43 38 34 30 26 23 85 72 62 53 46 39 34 30 26 22 20 83 78 72 67 61 56 52 48 44 40 37 83 76 68 61 55 48 43 39 35 32 29 83 83 73 71 64 61 56 53 50 45 43 39 38 34 34 29 29 25 26 22 23 19 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 1181 1923 3377 3805 3805 %Lamp 22.29 36.29 63.72 71.79 71.79 %Fixture 31.0 50.5 88.8 100.0 100.0 Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 69.5% Test Report: 2P2GX2U6T8S34I.IES LER = FP-56 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.32 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1513 1502 1474 1431 1377 1312 1237 1147 1041 930 799 628 429 223 75 33 15 6 0 Across ⊥ 1513 1516 1512 1495 1448 1391 1319 1215 1142 1094 1047 905 661 390 162 23 10 3 0 45° 1513 1511 1499 1474 1431 1359 1279 1184 1075 952 834 705 538 323 128 27 12 4 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 85 80 74 68 63 58 53 49 45 41 38 FB31T8/TL735/6 Lamps 2600 Lumens Candlepower 20% 50% 50 30 10 30% 50 30 10 50 80 72 65 59 53 47 42 38 34 31 28 76 70 63 57 51 46 41 37 33 30 27 73 67 61 55 50 44 40 36 32 29 27 80 71 62 55 48 42 37 33 29 26 23 80 69 60 52 45 38 33 29 25 22 19 76 68 61 54 47 41 37 32 29 25 22 76 67 58 51 44 38 33 29 25 22 19 10% 30 10 73 66 59 52 46 41 36 32 28 25 22 73 65 57 50 44 38 33 29 25 22 19 0% 0 72 64 56 49 42 36 32 27 24 20 18 Ty p i c a l VC P Pe r c e n t a g e s Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 63 60 71 65 75 69 75 71 79 75 Height Across 8.5’ 10.0’ 61 57 70 64 75 70 76 70 80 76 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 83 77 72 66 61 56 52 48 44 40 37 83 75 67 60 54 48 43 39 35 32 29 83 73 64 56 49 43 38 33 29 26 23 83 70 60 52 45 39 34 30 26 22 19 81 76 70 65 60 55 51 47 43 39 37 81 73 66 59 53 48 43 38 34 31 28 81 81 71 69 62 60 55 52 49 45 42 38 37 33 33 29 29 25 26 22 23 19 20% 50% 50 30 10 30% 50 30 10 50 77 70 64 57 52 46 42 37 34 30 27 74 68 62 56 50 45 40 36 33 29 27 71 65 60 54 49 44 39 36 32 29 26 77 69 61 54 47 41 37 32 29 25 23 77 67 58 51 44 38 33 29 25 22 19 74 66 59 53 46 41 36 32 28 25 22 74 65 57 50 44 38 33 29 25 22 19 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 1183 1922 3325 3684 3684 %Lamp 22.33 36.27 62.75 69.51 69.51 %Fixture 32.1 52.2 90.3 100.0 100.0 10% 30 10 71 64 58 51 46 40 36 32 28 25 22 Height Along 8.5’ 10.0’ 69 66 76 71 80 75 80 76 83 79 71 63 56 49 43 37 33 29 25 22 19 0% 0 70 62 54 48 42 36 31 27 24 20 18 Height Across 8.5’ 10.0’ 63 58 73 66 77 72 77 73 81 78 ORDER ING INFOR M A TION SAMPLE NUMBER: 2P2GAX-2U6T8S66I-UNV-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' Width P=Paralux Louver 2=2" Louver Depth Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (7) F=Aluminum Flange Trim (5) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Number of Lamps 2 lamps Wattage (Length) U6T8=32W T8 (24") Louver Color S=Silver W=White Cell Configuration 23=2 Rows of 3, 6 Cell 33=3 Rows of 3, 9 Cell 44=4 Rows of 4, 16 Cell Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard (Silver Only) MI=Specular/Mirrored (Low Iridescent) (Silver Only) P=Painted (White only) Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps=Lamps Installed (refer to lamp ordering options) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (6) Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% High Ballast Factor >1.15 No. of Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton Options PAF=Painted After Fabrication REP=Riveted Endplates ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) Option – Aluminum Flange Trim (5) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row (1) (2) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required (3) (4) per fixture. Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage (5) (6) must be specific. Specify row configuration, type in catalog number when ordering complete fixture. Fixtures equipped with “EL” option may require a (7) 5-1/2" housing depth. If installing in field, must use low profile battery pack. Louver is recessed by 5/16" in Concealed T or Slot Grid T. SH IP P ING D A T A For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Catalog No. 2P2GAX-2U6T8S44I Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Wt. 28 lbs. ADF090415 2015-10-13 15:11:51