Building Consistency Meeting Residential Date: 7/07/2010 Recorder and minutes prepared by: Danny Wooten/Lon McSwain Staff present: Danny Wooten, Eric Brown, Druied Roberson, Steve Lineberger, Ron Dishman, Tim Taylor, Walt Nash, Barry Human, Patrick Biddy, Dave Ries, Gene Morton, Lon McSwain, Greg Walsh, David Williams, Harold Sinclair, Billy Yandle, Robert Richardson, Jeff Griffin, Ken Turull, Ron Featherstone, Tom Shoupe, Don Sprinkle, Randy Newman, Steve Kellen, Andy DeMaury, David Williams, Scott Commander, David Pethel, Kirk Aten, Hugh Moose, Steve Miller, Mike Jackson, Russ Fischer, Ralph Vernon, Debra Parris, Steve Person, George Rogers, Melanie Sellers, Tony Kiser, Eric Brown. Public present: Kenneth Rampersad (Soto Construction); David R. Schwieman (D.R. Schwieman, Inc.); Rob Merrell (Griffin Masonry); Wayne Carter (Lifestyle Homes); Terry Cleary (Meeting Street Homes); Bob McKee (Ryan Homes); Darren Price ( M/I Homes); Charles Sofinowski (M/I Homes); Joe Stewart (Build 1st Source); Topics/Subject Decisions/Conclusions/Actions Old Business . New Business Re-Org R302 Townhouse separation and protection. Townhouse soffits Handout Flyers were distributed detailing the Re-Org process and contact information. Section R302.1 does not allow any projections within 2’-0” of a property line. As an alternate method per the 2009 Administrative Code, Section 105, We are requiring that the first three feet of any projection adjacent to the property line be 1 hr rated from the underside. These projections would include, but not limited to soffits, cantilevered floors and porch columns and ceilings. Section R-302 requires the entire soffit be protected with no openings within 4’-0” of the party wall. (non-com, frt, gyp bd, ect). There is a field inspection issue in that if the finished product is the approved noncombustible material like fiber cement board then it can be viewed at final inspection. If the builder is using protection that will be underneath the vinyl soffit material and not visible at the final then it must be installed at frame check. Required on all jobs permitted on or after 07/07/2010 Amendments to the code that take effect on 01/01/2011 R302.4 Flame spread on vinyl soffit material. R311.2.2 Under stair protection R311.5.8 Special stairways R313 Carbon monoxide detectors. R404.5 Retaining walls (deleted) AG106.1 Pool suction outlets Appendix M Wood decks R403.1 Continuous footings These can be found on DOI Web Site http://www.ncdoi.com/OSFM/Engineering/BCC/engineering_bcc_code s_2012_proposed.asp Approved By ___Lon Mcswain_________ Date _______07/07/2010_______________ F:\CORE\CORESUP\KATHY\GENE\CDEINTRP\wythe.doc