Building Consistency Meeting Residential Date: 10/03/12 Recorder and minutes prepared by: Danny Wooten/Jeff Griffin/Lon McSwain Staff present: On file. Public present: ; Charles Sofinowski (MI Homes); JonathonHess/Mike Winn (Ryan Homes); Chris Carroll (Meeting Street); Jeff Gerdes (Livewell); Wayne Carter ;Daniel McBride;Joel Presson (J-Kap Construction); Stroud, (Pulte Homes);Bill Green, (Barefoot);Banks Pickens (Shea Homes);Brian Hall (Classica Homes);Curt Hathaway ( Providence Partners);Dave Reynolds(Builders First Source);Kenny Childers, Brian Jones (Cornerstone Builders Group);Austin Gregory (I D Enginering);Marcel Papineau (IED);Darren Price; Stefani Hendly( M/I Homes);Philip Tilley (Cabarrus County Inspections);David Schwieman (DR Schwieman) Topics/Subject Decisions/Conclusions/Actions Old Business None New Business New Training Schedule Retaining Walls Section R404.4 Steps Built in to a Retaining Wall Smoke Detectors Pre-decking Inspections Soffit Protection R703.11.3 Attic Fall Protection The new training schedule for staff the first Wednesday of every month will start with consistency meetings (open to the public) from 8:00 to 10:00 and 2 additional hours from 10:00 to 12:00 for staff only. The height of the unbalanced fill retained shall be measured at a point 10’ behind the wall for every 1’ of wall height. Section 1807.2.5 of the commercial building code used as a guide. For every 1 foot in height of the retaining wall measure 10’ behind the wall to obtain the height of unbalanced fill retained by the wall. Additional information will be provided at the next consistence meeting. When steps are part of the retaining wall they will be covered by the permit for the wall and need to meet the requirements for stairs in the Residential Code. When smoke detectors provided are part of an alarm system then a certification from the alarm company is required showing that they are an approved UL listed monitoring station under NFPA 72 A pre-decking of the floor system is not a required inspection unless there is low ground clearance that would make it difficult to perform an inspection after the deck is in place. Soffit protection required by section R703.11.3 applies to the entire soffit of a dwelling if any portion of the soffit is within 10’-0” of the lot line. Fall protection must be provided for all floored attics, at the edges of the flooring, that are accessed by a fixed stair or door. Exceptions for floored areas where the rafters are less than or equal to 36” from the floor to the bottom of the rafter and floored areas that are for mechanical equipment access only. Interpretation was handed out and will be posted on the web shortly. Wind Bracing Staples are not acceptable to be used in attaching elements used in wind bracing on plywood/osb sheathing option. Guards at Retaining Walls CO Guards are not required on retaining walls were the top of the wall is more than 30” above adjacent grade if the walking surface is located more than 36” behind the face of the wall. A CO can be issued on a house if a detached garage is not finished and is on a separate permit. The same for a pool. The construction area must be separated from the house in some manor to provide safety for the occupants of the house. House wraps must be installed per the manufactures instructions and per the ESR. House Wraps Approved By ___Lon McSwain_________ Date _____07/09/2012__