80E30 ... Codeline Pressure Vessel model

advertisement
Codeline Pressure Vessel model 80E30
PART
DWG
QTY
REF
NUMBER
DESCRIPTION
MATERIAL
SHELL
01
1
ORDER
SECTION
SHELL
Filament Wound Epoxy/Glass composites - SS
Head locking grooves integrally wound in place.
02
2
51050
Bearing Plate
6061-T6 Aluminium Alloy-Hard Anodized.
03
2
96003
Sealing Plate
Engineering Thermoplastic.
04
2
50607
Feed/Conc Port
316L Stainless Steel.
05
4
45247
Port Retainer
304 Stainless Steel.
06
2
50608
Permeate Port
Engineering Thermoplastic.
07
2
96000
Head Seal
Ethylene Propylene - O Ring.(442)
08
4
45312
Port Seal
Ethylene Propylene - O Ring.(225)
HEAD
HEAD INTERLOCK
09
2
47336
Retaining Ring
316 Stainless Steel
VESSEL SUPPORT
10
*2
52169
Saddle
Engineering Thermoplastic.
11
*2
45042
Strap Assy.
304 Stainless Steel - PVC cushion
12
4
46265
Strap screw.
5/16-18 UNC, 18-8 Stainless Steel.
13
2
A/R
Adapter
14
4
A/R
PWT Seal
15
2
52245
Adapter seal
16
1
45069
Thrust Ring
ELEMENT INTERFACE
Engineering Thermoplastic.
Ethylene Propylene - O - Ring
Ethylene Propylene - O - Ring (124)
Engineering Thermoplastic.
* 3 Each Furnished With Length code 4, 5, 6 & 7.
www.lenntech.com
info@lenntech.com
RATIN G:
PRECAUTIONS:
ORDERING:
DESIGN PRESSURE…… ……..….30 0 PSI at 120°F
(2 .1 MPa @ 49 °C)
M IN. OPERATING TEMP… …...……… ……...20°F
(-7°C)
FACTORY TE ST PRESSURE……… CE / ASME
450 / 39 0 PSI
(3.1Mpa) / (2.7 M Pa)
BURST PRESSURE… …..…… ……… .… ..1800 PSI
(12.4 MPa)
DO …read,
understand
and
fo llo w
all
in structions; failure to take every precau tion
will vo id warranty and may result in v essel
failu re
DO …mou nt th e shell on horizontal members at
s pan “S” using complaint vessel s upports
furnished ; tighten hold do wn straps just snug
DO …provide overpressure p rotection for vessel
s et at not m ore than 105% o f d esign pressure
DO …insp ect end closures regularly; replace
comp onen ts that have deterio rated and
correct causes of corrosion
Usin g the chart below, p lease check the
features you require an d fax them with
you r pu rch ase ord er to our customer
service d epartment for expedited
processing.
For optional materials an d/or features
not listed b elow, please cons ult factory
fo r pricing and availability.
INTENDED USE:
The CodeLine Mod el 80 E30 Fib erglass RO Pressu re
Vessel is designed for continuous, long term use as a
h ousing for reverse osm osis membrane elements to
d esalt typical brackish waters at pressu res up to 300
p si. An y mak e of eigh t-inch nominal diameter spiralwound element is easily accommodated; the
appropriate in terfacing h ardware for the element
sp ecified is furnished with the vessel.
The Cod eLin e Mo del 8 0E30 is designed in
accordance with th e engineerin g standards of the
Boiler and Pressure Vess el Code of the American
Society of Mechanical En gin eers (ASME Co de). At
small add ition al cost, vessels can be in spected during
construction b y an ASME Authorized inspector and
ASM E Code stamped.
The CodeLine Mod el 8 0E30 must be installed,
op erated and maintained in accordance with the listed
p recautions an d good industrial p ractice to assu re
safe operation over a long service life.
The high performance reinforced plastic sh ell mu st
b e allowed to expand under pressure; undu e restrain t
at sup port points o r pip in g connection s can cause
leaks to develop in the sh ell. Th e end clo sure,
incorporating close fitting, interlocking metal
compon ents, mu st be kept d ry and free of corrosion;
d eterioration can lead to catastrophic m echan ical
failure of the h ead.
The end closures, in corporating close-fitting,
interlocking m etal compo nents, must be kept dry and
free of corrosion; deterioration can lead to
catastro phic mechanical failure of the h eads.
Pentair Water will assist th e purchaser in determining
th e suitability of this stan dard vessel for th eir sp ecific
op erating co nditions. Th e final determination
h owever, includ ing evalu ation of th e standard
material of construction for compatibility with the
sp ecific corrosive environ men t, shall be the
respo nsibility of the purchaser.
Specifications are subject to chan ge withou t notice.
DWG.No. 99111-H2
© Pentair Wat er
Page 2 of 2
DO NOT… make rigid piping conn ections to
p orts o r clamp vessel in any way that resists
g rowth of fiberglass shell und er p ressure;
∆DIA = 0.0 15 in. (0.4 mm) and ∆L = 0.2 in.
(5mm) for a len gth code –7 vessel
DO NOT… hang piping manifolds from ports or
u se vessel in any way to s upport o ther
comp onen ts; branch con nection pipin g may
b e simp ly s upported between the head er and
p ort; maximum weig ht of branch p ip ing;
feed/concen trate – 16 lb s (7 .3 kg); permeate
– 8 lbs (3.6 kg)
DO NOT… op erate vessel at p ressu res and
temperatures in excess of its rating
DO NOT… operate vess el without permeate
p orts internally conn ected with a com plete
s et of elements and interconnectin g
h ardware
DO
NOT… operate vessel with permeate
p ressure in excess of 1 25 psi at 1 20°F
(0.86 MPa @ 49°C)
DO NOT… ov ertigh ten the connection to the
p ermeate p ort (h an d-tighten plus one-q uarter
tu rn, check for leaks)
DO N OT… tolerate leaks or allow end closu res
to be routinely wetted in any way
DO NOT… pressurize v essel until dou blecheck in g to verify that th e retain ing rin g is
comp letely inside the groove
DO NOT… wo rk on any component until first
v erifying that pressure is relieved from
v essel
DO NO T… op erate at pH levels belo w 3 or
abo ve 10
Please note that we require your
membrane brand and mod el numb er
wh en ordering. If this information is n ot
initially available, you may provide it at
a later date by checking th e app ropriate
bo x b elow.
VESSEL LEN GTH CODE – please check one
MODE L 8 0E30 -1 -2 -3 -4 -5 -6 -7
MEMBRANE BRAND AND MODEL – please check one a nd fill in info rmatio n
Please su pply adapters for th e followin g membrane b rand and specific model
Brand____ ______ ______ ______ ___Mod el____ ______ ______ ______ _
CER TIFICATION REQUIRED
ASME Stamped and National Board Registered
(please consult fact ory for pricing)
CE M arked
Standard, Certified by Pentair water.
EXTER IOR FINISH – please check one
Standard – white high-glo ss p olyurethane coating.
Option – option al colors are availab le for 50 or more vessels per order.
Call factory for pricing details.
MATERIAL OPTIONS
Standard – All materials as per drawing 99111 on th e first page.
Cu stomer sp ecified materials: (Please consult the factory, as these options will affect pricing and vessel lead-tim e.)
>ĞŶŶƚĞĐŚďǀ
ZŽƚƚĞƌĚĂŵƐĞǁĞŐϰϬϮŵ
ϮϲϮϵ,,ĞůĨƚ
dĞů͘нϯϭͲϭϱͲϮϲϭ͘Ϭϵ͘ϬϬ
&Ădž͘нϯϭͲϭϱͲϮϲϭ͘ϲϮ͘ϴϵ
www.lenntech.com
info@lenntech.com
Download