Increased Availability for BBC/Alstom Gas Turbines Turbine Controls Instrumentation, Controls & Electrical SPPA-R3000 Turbine Controls is the perfect modernization solution with comprehensive automation functions for gas and steam turbines from any vendor. Your Benefits ■ Increased availability and lifetime ■ Increased operational reliability ■ Increased flexibility ■ Reduced maintenance costs The Task In addition to expensive spare parts warehousing, increasing failure probability affecting the mechanical and electrical components utilized to control and protect Alstom gas turbines results in decreasing availability and deteriorating operational reliability. The main turbine and generator components still retain a high residual lifetime. The old control and protection systems are no longer up to the task of meeting today's requirements for cost-effective operation of the turbosets. Our Solution SPPA-R3000 offers concepts that are adapted to the specific requirements of BBC/ABB/Alstom gas turbines of types GT 9, 11, and 13 and have proven their worth over and over in operation. In addition to the control system, the modernization solution can also include vibration monitoring and analysis, electrical engineering, modernization of the hydraulic system, and field instrumentation. The basis is the globally leading SPPA-T3000 control system that forms the platform for automation, control and protection. It is employed for turbines, auxiliary systems and the main control system and permits seamless integration of all functional areas of the plant. Thanks to its scalability, it can be used not only as a stand-alone turbine solution but also for modernization of the entire plant with a uniform operating and engineering environment. Our service portfolio comprises everything from feasibility studies to the realization of basic functionalities for Alstom gas turbines, fail-safe protection with SIL3 certification, installation/commissioning, and complete documentation. Modernization can help to eliminate systembased failures of the legacy system as well as performance losses that were previously caused by aging effects on the field and control devices. Replacement of the mechanical overspeed protection with electronic protection (SIL3certified), eliminating the real run-up to the overspeed value, protects the turbine. In case of a fault, automated expert alarming using a paging system, along with remote diagnostic capability for maintenance personnel, ensures reduced downtimes. The bus connection of the electrical systems to the main control system via IEC 61850 ensures faster diagnostics all the way to the field level. The higher degree of automation also facilitates operations, eliminating the need for manual intervention. Improved mapping of the plant processes and elimination of former interface problems reduce the overall plant start-up time and avoid turbine emergency shut-offs. Modernization by replacing the legacy systems with Siemens technology takes place during planned turbine overhaul without causing additional downtime. SPPA-R3000 increases the availability of BBC/Alstom gas turbines – e. g. in Kriel Power Station, South Africa. Answers for energy. The solution can include: Control system (open-loop control, closed-loop control, protection) Vibration monitoring and analysis Electrical engineering (excitation system, synchronization, unit protection facilities) Hydraulic modernization Field instrumentation Our service portfolio: Execution of a feasibility study Conceptual design – technological outlining of the task definition Functional extension to increase cost-efficiency, e.g. test functions to reduce maintenance effort Customized adaptations of the solution, e.g. modification of the operating mode Fail-safe protection with SIL3 certification Installation/commissioning with optimized timing Before/after tests (fingerprints) Complete documentation Realization of the basic functionalities for Alstom gas turbines, e.g. single-burner control Studies and Consulting Offer Test Run ‘before’ Mod., Engineering, Tests , Planning, Realization Manufacturing Installation Commissioning Test Run ‘after’ Mod. Training After-Sales Service Quality Management Our comprehensive service portfolio ranges from studies and consulting to after-sales service and is notable for its first-rate quality management. Published by and copyright © 2012: Siemens AG, Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany For more information contact sppa-r3000.energy@siemens.com www.siemens.com/energy/sppa-r3000 Siemens Energy, Inc. Instrumentation, Controls, & Electrical 1345 Ridgeland Parkway, Suite 116 Alpharetta, GA 30004, USA R30GT_FS_Alstom-Mod_e_V2-0 Order No. E50001-G230-A304-X-4A00 Printed in Germany Dispo 05401, c4bs-Nr. 7465 Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.