CF888 PVC - e-chain® - Bus cable for flexible load requirements (class 3.1.1): shielded as well as flame-retardant. Overview Bus system Part. No. Profibus CF888.001 Ethernet (CAT5e / GigE / PoE) CF888.045 34 mm Example drawing (see the chapter belonging to the cable for details) (see the chapter belonging to the cable for details) Core design: Conductor: Wire strand consisting of bare copper wires (following DIN EN 60228). Core insulation: According to bus specification. Core identification: According to bus specification. Shield design: Material: Braid made of tinned copper wires combined with an aluminium clad plastic foil. Shield coverage (optical): approx. 60 % (Braid) (Foil) 100 % Jacket design: Outer jacket: Low-adhesion mixture on the basis of PVC adapted to suit the requirements ® in e-chains . flame-retardant (following IEC 60332-1-2, CEI 20-35, VW-1 & FT-1) silicon-free (following PV 3.10.7 - status 1992) lead-free (following 2011/65/EU (RoHS-II)) UV-resistance: Low Colour outer jacket: Red lilac (similar to RAL 4001) Cable marking (Black): „00000 m“* igus chainflex CF888.--- ----- E310776 cяUus AWM Style 2560 VW-1 AWM I/II A/B 60°C 30V FT-1 CE --- conform RoHS-II * Length printing: Not calibrated. Only intended as an orientation aid. / : Cable identification according to part no. (see technical table for details). Ex.: CF888.001: …chainflex CF888.001 (2x0,25)C CE… : Printing according to bus specification (inclusive wave resistance). Ex.: CF888.001: …CE 150 OHM Profibus conform… General mechanical values: (for individual details see technical table) Double strokes Temperature (from/to) [°C] +5 / +15 +15 / +60 +60 / +70 1 million Travel distance (TD) Min. bending radius for e-chain® use [Factor multiplied by outer diameter (d)] (Ex.: CF888.001 at 20°C: 15,0 x 8,0 mm Min. bending radius 120,0 mm) 17,5 15,0 17,5 ≤6m (unsupported) : Minimum guarantee lifetime of the cable under the specified conditions. The installation of the cable is recommended within the middle temperature range. igus® chainflex® M CF888 Temperature range Min. bending radius for fixed installation Torsion (at 1 m cable length) Image exemplary +++ chainflex cable works +++ -20 °C 15,0 x d --- +5 °C 12,5 x d ±0 ° +15 °C +60 °C 10,0 x d ±15 ° +70 °C 12,5 x d ±0 ° General electrical values: (for individual details see technical table) Nominal voltage: 50 V Test voltage: 500 V (core / core) & 500 V (core / shild) following DIN EN 50289-1-3 Certifications: Guidelines: : (E310776: Style 1589 & 2560, 30 V / 60 °C) CE, NFPA (following 79-2012 chapter 12.9), EAC & TR (CTP) Date Subject to misprints and errors. 26 Jun. 2014 Technical modifications are possible at any time. Please refer regarding the availability of the items also the information in the latest chainflex® catalogue. Author D. Borsberg Page 1/4 www.igus.de +++ chainflex® cable works +++ conform www.igus.de CF888 PVC - e-chain® - Bus cable for flexible load requirements (class 3.1.1): shielded as well as flame-retardant. Dynamic values: Max. speed ® for e-chain use:** Unsupported (up to 6 m): v = 3 m / s Max. acceleration ® for e-chain use:** a = 20 m / s ** 2 These values are based on specific applications or tests. They do not represent the limit of what is technically feasible. Typical lab test setup for this cable group: Test bending radius R: approx. 100 mm Test travel S: approx. 1 - 5 m Test period: min. 1,0 - 1,5 million double strokes Test speed: approx. 0,5 - 2 m / s Test acceleration: approx. 0,5 - 1,5 m / s 2 for 1 million movements (double strokes) in e-chains for areas of application without influence of oil for unsupported travel distances up to 6 m CE, RoHS-II, , NFPA, EAC & TR (CTP) ® Typical application areas: Preferably indoor applications. Wood/stone processing, packaging industry, supply system, handling, adjusting equipment. Technical tables: Mechanical values: Part no. Number of cores & nominal cross section [mm²] External diameter (d)*** [max. mm] Copper index [kg / km] Weight [kg / km] Profibus CF888.001 (2x0,25)C 8,0 19 62 7,5 27 68 Ethernet (CAT5e / GigE / PoE) CF888.045 igus® chainflex® M CF888 *** Image exemplary (4x(2x0,15))C External diameters are maximum values and may tend toward lower tolerance limits. Electrical values: Nominal cross section [mm²] Conductor resistance [approx. Ω / km] at 20 °C (following) DIN EN 50289-1-2 Max. current rating [A] at 30 °C DIN VDE 0891-1 0,15 149 2,5 0,25 78 5 Date Subject to misprints and errors. 26 Jun. 2014 Technical modifications are possible at any time. Please refer regarding the availability of the items also the information in the latest chainflex® catalogue. Author D. Borsberg Page 2/4 www.igus.de +++ chainflex® cable works +++ e-chain® - Bus cable for flexible load requirements: CF888 PVC - e-chain® - Bus cable for flexible load requirements (class 3.1.1): shielded as well as flame-retardant. The max. current rating depends on factors such as the individual environmental conditions and the type of installation. Image exemplary www.igus.de igus® chainflex® M CF888 +++ chainflex® cable works +++ Date Subject to misprints and errors. 26 Jun. 2014 Technical modifications are possible at any time. Please refer regarding the availability of the items also the information in the latest chainflex® catalogue. Author D. Borsberg Page 3/4 CF888 PVC - e-chain® - Bus cable for flexible load requirements (class 3.1.1): shielded as well as flame-retardant. CF888.001 (Profibus) Conductor: Wire strand consisting of bare copper wires Outer jacket: Pressure extruded PVC mixture Core insulation: Mechanically high quality TPE mixture Overall shield: Braid made of tinned copper wires (According to bus specification) Banding: Plastic foil Filler: Plastic yarn Shield foil: Aluminium clad plastic foil Electrical values: Characteristic wave resistance: 150 ± 15 Ω ( 1 MHz) following DIN EN 50289-1-11 Construction table: Part No. Colour code CF888.001 2x0,25 Cable construction red, green CF888.045 (Ethernet (CAT5e / GigE / PoE)) Outer jacket: Pressure extruded PVC mixture Conductor: Wire strand consisting of bare copper Core insulation: Mechanically high quality TPE mixture Overall shield: Braid made of tinned copper wires (According to bus specification) Shield foil: Aluminium clad plastic foil Electrical values: Characteristic wave resistance: 100 ± 15 Ω (at 1 MHz to 250 MHz) following DIN EN 50289-1-11 Construction table: Part No. CF888.045 Colour code 4x(2x0,15) Cable construction whiteblue/blue, whiteorange/orange, whitegreen/green, whitebrown/brown www.igus.de +++ chainflex® cable works +++ Banding: Plastic foil igus® chainflex® M CF888 (According to EIA/TIA 568) Image exemplary (Back to overview or technical table) Date Subject to misprints and errors. 26 Jun. 2014 Technical modifications are possible at any time. Please refer regarding the availability of the items also the information in the latest chainflex® catalogue. Author D. Borsberg Page 4/4