Field Service Bulletin Modifying BIOS Settings to Improve Operational Reliability of R189 One-Net™ SE with 1.6GHz Processors Shipped Prior to September 1, 2011 Several One-Net SE units with 1.6GHz processors have been found with improper BIOS settings from the vendor. Under certain operating conditions these units might intermittently shut down and prevent subsequent reboots. This procedure resets the BIOS operating conditions to ensure the units are properly configured. This Field Service Bulletin applies only to very specific R189 One-Net SE models with 1.6GHz processors. Customers who have this configuration are strongly urged to apply the procedure described below. This updating procedure takes approximately 3 minutes to perform. Verifying If Update Is Necessary To confirm if this procedure applies to your unit, log into the unit via web browser. Select the SERVER > STATUS > CPU. In the CPU list, look for the number next to CPU MHz. If the number is 1599.xxx, this procedure applies to the unit. Other speed CPU’s are not affected by this procedure. Refer to Figure 1 Electrostatic Measurement Emergency Alert Systems CATV Switching and Control 585-765-2254 fax 585-765-9330 100 Housel Ave. | Lyndonville | NY | 14098 www.monroe-electronics.com Revision: 1 Publication: FSBEAS-9811 Copyright © 2009-2010 Monroe Electronics Inc. Information herein is considered accurate at the time of publication. We constantly strive to improve our products and services therefore some specifications are subject to change without notice. Monroe Electronics Field Service Bulletin Figure 1. CPU information screen. Affected units show cpu MHz 1599.968 Equipment Required The updating procedure requires direct connection to the R189 One-Net chassis and cannot be performed via the standard web interface. You must attach directly to the keyboard and VGA output connectors on the One-Net. A mouse is not required. a. Standard PC Keyboard with PS-2 or USB connector b. Standard PC VGA Monitor Update Procedures 1. Power down the unit to be modified by momentarily pressing the power rocker switch on the back panel. Wait for the unit to complete its shutdown procedure and power off. 2. Connect the keyboard and monitor to the keyboard and VGA ports on the ONENET rear panel. (The keyboard connector is purple if using PS-2) 3. Power up the unit by again pressing the power switch. 4. As soon as the unit starts to boot, press the DELETE key to enter the BIOS settings page. 5. After the BIOS setting page is displayed press the down arrow to select PC HEALTH STATUS as shown in Figure 2. Field Service Bulletin: Modifying BIOS on R189 One-Net SE with 1.6GHz Processors Page 2 of 7 Monroe Electronics Field Service Bulletin Figure 2. BIOS screen. Select PC Health Status 6. Press ENTER. The PC Health Status screen should appear with the Shutdown Temperature field highlighted as shown in Figure 3. Figure 3, PC Health Status screen with Shutdown Temperature field highlighted. 7. Press ENTER. A selection menu appears. 8. Using the arrow keys move the selection box to “Disabled”. 9. Press ENTER returns to the PC Health Status screen. Field Service Bulletin: Modifying BIOS on R189 One-Net SE with 1.6GHz Processors Page 3 of 7 Monroe Electronics Field Service Bulletin Figure 4. PC Health Status screen after selecting proper Shutdown Temperature. 10. Using the arrow keys highlight the CPU Thermal-Throttling Temp field as shown in Figure 5. Figure 5. Selecting the CPU Thermal-Throttling Temp 11.Using the “Page Up” and the “Page Down” keys change the value to “75”. Field Service Bulletin: Modifying BIOS on R189 One-Net SE with 1.6GHz Processors Page 4 of 7 Monroe Electronics Field Service Bulletin Figure 6. PC Health Status screen after selecting proper Throttling Temp. Field Service Bulletin: Modifying BIOS on R189 One-Net SE with 1.6GHz Processors Page 5 of 7 Monroe Electronics Field Service Bulletin 12. Using the arrow keys highlight the CPU Thermal-Throttling Duty field as shown in Figure 7. Figure 7. Selecting the Thermal-Throttling Duty. 13.Press ENTER. A selection menu appears. 14.Using the arrow keys move the selection box to “75”. 15.Press ENTER returns to the PC Health Status screen. Figure 8. PC Health Status screen after selecting proper CPU Thermal-Throttling Duty. Field Service Bulletin: Modifying BIOS on R189 One-Net SE with 1.6GHz Processors Page 6 of 7 Monroe Electronics Field Service Bulletin 16. Press F10 and the following screen should appear: 17. Press ENTER. 18. The unit should now re-boot and be ready for service. 19. Disconnect the keyboard and monitor. Customers uncomfortable or unable to perform this update are asked to contact the factory at eas@monroe-electronics.com or via telephone at 585765-2254 for additional assistance. Field Service Bulletin: Modifying BIOS on R189 One-Net SE with 1.6GHz Processors Page 7 of 7