BELL SYSTEM PRACTICES SECTION 461-400-150 AT&TCo Issue 2, January Standard 625TD CONNECTING IDENTIFICATION STANDARD CUSTOMER NETWORK PARTICIPATION This section provides information on the 625TD connecting block which is the standard net~vork interface for new service arrangements. (a) Expand information necting block on wiring of 625TD con- designations g K 3. The 625TD connecting block shall be installed at a point inside the customer premises \vhere the customer or customers representative has control of access to it. This point should be as close as possible to the main entrance terminal or drop termination, and still meet the above requirements. In single family units with unfinished basements, the 625TD would normally be mounted directly through the \vall from the outside mounted protector. In multiunit construction, finished basements, slab construction, etc, the 625TD location must be negotiated with the builder at the time of construction since it must interface with the distribution facilities as well as \vith the premises inside wiring. (a) 625T swinger assembly block base unit (d) Plastic covered (Fig. 2). silver foil instruction label The 625TD connecting block should be mounted in a horizontal plane with the modular jack to the right as you face the jack, so the instruction label can be read and the jack cover strings upward. 3.02 A second connecting block, coded 625 TD-2, will be made available w-hich will contain a second terminating unit when terminating a second line in the same connecting block. 2.02 2.03 INSTALLATION 3.o1 The 625TD connecting block assembly (Fig. 1) is made up of the following: (c) Line termination The terminating unit must always be used with the 625 TD connecting block. R and extra callouts IDENTIFICATION (b) 42B connecting company The termination unit in the 625TD connecting block provides a recognizable capacitive loop test (approximately 1/2 of a normal ringer) to Bell System test equipment. This prevents the line from testing open (unterminated) when terminal equipment is disconnected from the connecting block modular jack. Revision arrows are used to emphasize the more significant changes. The Equipment Test List (ETL) is not affected. 2.01 PRODUCTS 2.04 1.02 This section is reissued to:. 2. ‘ ~;-;q$ f--J:, #. ! L =-.5/,;}. ; ~jR,, ,; ;n p ?%; . f i a:m,~ ‘i4! #~,.+J ..-. j’ r= —-’----_.__-= j -..+ premise wiring and Bell System telephone network facilities. 1.01 (b) Add terminal to Fig-. 1. INTERFACE ARRANGEMENTS GENERAL 1. BLOCK AND INSTALLATION NEW SERVICE 1982 The 625TD connecting block will be the standard network interface between customer 3.03 Breakouts have been pro~’ided in the connecting block base at the bottom and at the ends. NOTICE Not for use or disclosure Bell System except under Printed outside written in [J,S.A. the agreement Page 1 SECTION 461-400-150 It is recommended that the bottom entrance be used and that no other breakouts be made in the base other than the entrance used. This will maintain maximum resistance to humidity and contamination. (b) A two line termination block: (1) The ring of the first line, one lead of the terminating unit, and the red Ica(i of the jack on terminal R. The box should be mounted so there is sufficient space around it for bridging arrangements. This unit will normally be used in conjunction with an entrance bridge which may be company or customer provided. 3.o4 (2) The tipof the first line, the other lead of the terminating unit, and the gr(’en lead of the jack on terminal G.4 The wiring of the 625TD should be as follows: 3.05 (a) $A one line termination block:$ – 625TD connecting (3) The rin~ of the second line, one lead of the second terminating unit, and the yello~r lead of the jack on terminal Y. (1) The ring of the first line, one lead of the terminating unit, and the red lead of the jack on terminal R. The tip of the second line, tht’ other lc’ad of the second terminating unit, an(] the black lead of the jack on terminal Il. (4) (2) The tip of the first line, the other lead of the terminating unit, and the green lead of the jack on terminal G. After the installation has bcwn conll)]eted, the customer should be advise(l of the standar(l netlvork interface, its location, and the instructions on the label. 3.06 (3) $The yellow lead of the jack on terminal (4) The black lead of the jack on terminal Page 2 Y. B. – 625T1)-2 connecting i 1SS2, SECTION 461-400-150 / Y I 1 ‘1 R2(Y) T2(BK) ,,. .lTNE $ ‘“’A’h TERMINATII)N IT (R) f \ \ FOR FIRST LINE TERMINATION xl T1(G) \ WIR BRE o BREAKOUTS TING BASE WIRE BREAKOUT Fig. l—$Exploded RECEIVING TERMINATION SERVICE View SLOTS FOR THE SECONO UNIT FOR TWO LINE of 625TD Connecting LINE Blockt Page 3 SECTION 461-400-150 DISCONNECT PLUG THIS JACK DURING INSTALLATION AND REPAIR OF WIRING ● TESTING FROM M @ PLUG WORKING PHDNE DIRECTLY U--.-J INTO THIS JACK. IF PHONE OPERATES. FAULT IS IN WIRING. IF PHONE DOES NOT OPERATE, REPAIR SERVICE CALL I \ PLUG-ENDED CORD l\ INSTRUCTION LABEL Fig. 2—~625TDor I f f Page 4 4 Pages 625TD-2 Connecting Blockt