Hellenic Accreditation System Annex G1/3 to the Certificate No. 805 SCOPE of ACCREDITATION of the Clinical Laboratory of Iatriki Diagnosi Ltd. Materials/Products tested Types of test/Properties measured Applied methods/Techniques used Biochemical Tests 1. Blood serum Page 1 of 3 Determination of 16 parameters Automated biochemical analyzer Dimension RXL, SIEMENS* 1. Glucose Enzymatic Chromatometric Reaction: Hexokinase 2. Urea Enzymatic Chromatometric Reaction Kinetic: Urease 3. Uric Acid Enzymatic Chromatometric Reaction: Uricase 4. Serum glutamic-oxaloacetic transaminase (SGOT) Enzymatic Chromatometric Reaction: Siemens/ Date, Standard nonIFCC 5. Serum glutamic-pyruvic transaminase (SGPT) Enzymatic Chromatometric Reaction: Siemens/ Date, Standard nonIFCC 6. Gamma-glutamyl trasferase (γGT) Chromatometric Reaction: Siemens/ Date, Standard nonIFCC 7. Triglycerides Enzymatic Chromatometric Reaction: Lipase 8. Creatinine Enzymatic Chromatometric Reaction: Alkaline Picrate no Deprot 9. C Reactive Protein (CRP) Turbidimetric 10. Alkaline phosphatase (ALP) Chromatometric Reaction: AMP buffer 11. HDL Cholesterol Chromatometric Reaction: direct HDL, PPD 12. Iron Chromatometric Reaction: without PPT 13. Total Cholesterol Chromatometric Reaction: Siemens/ Date Reagent 14. LDL Cholesterol Calculated 15. Total Proteins Chromatometric Reaction: Bichromatic Endpoint 16. Total Iron Binding Capacity Ferene Direct - Chromatometric Reaction: Bichromatic Endpoint Annex G1/3 to the Certificate ESYD No.805 09.01.2015 Materials/Products tested 2. Whole blood (EDTA) Types of test/Properties measured 17. Determination of glycated hemoglobin A1c ( HbA1C ) Applied methods/Techniques used Turbidimetric (HB1C) & Alkaline Hematin RXN (Hb) Hematological Tests 1. Whole blood (EDTA) Determination of 12 parameters Automated analyzers SYSMEX XS-1000i, ROCHE* 1. Haemoglobin Chromatometric Reaction: SLS Hb Detector 2. Red Blood Cells (RBC) Hydrodynamic Focusing 3. Platelets (PLTs) Hydrodynamic Focusing 4. White Blood Cells (WBC) Flow Cytometry (Semiconductor Laser) 5. Hematocrit (HCT) Hydrodynamic Focusing 6. Mean Red Cell Volume (MCV) Calculated Based on Specific Equation (DC Detection) 7. Mean Platelet Volume (MPV) Calculated Based on Specific Equation (DC Detection) 8. Mean Cell Hemoglobin Calculated Based on Specific Equation (DC Detection) 9. Calculated Based on Specific Equation (DC Detection) Mean corpuscular hemoglobin concentration 10. Red Cell Dist.Width CV Calculated Based on Specific Equation (DC Detection) 11. Red Cell Dist.Width SD Calculated Based on Specific Equation (DC Detection) 12. Plateletcrit Calculated Based on Specific Equation (DC Detection) Determination of 2 parameters Αnalyzer VARIANT II , BIORAD * 1. Hemoglobin A2 (HbA2) HPLC (High Perfomance Liquid Chromatography) 2. Hemoglobin F (HbF) HPLC (High Perfomance Liquid Chromatography) 3. Whole Blood (EDTA) Determination of 1 parameter Αnalyzer VARIANT II TURBO, BIORAD * 1. Glycosylated Hemoglobin (HBΑ1c) HPLC (High Perfomance Liquid Chromatography) 4. Blood Plasma (Citrate) Determination of 3 parameters Semi-automated, Coagulation Analyzer BFT II (SIEMENS) * 1. Prothrobin Time (PT sec) Mechanical and photo-optical clot detection turbodensitometric 2. Whole Blood (EDTA) 2. Prothrobin Time (INR) 3. Activated Partial Thromboplastin Time (APTT) *Reference to the commercial name of a specific analyzer/kit, refers to a specific analytical method and protocol Page 2 of 3 Annex G1/3 to the Certificate ESYD No.805 09.01.2015 Site of assessment : Laboratory permanent premises, 48th Demokratias Av., 187 56 Keratsini, Attiki, Greece. Approved signatories : A. Kotsigianni, M. Tsigka. This scope of Accreditation replaces the previous one dated 30.09.2013 The Accreditation Certificate No. 805, to ELOT EN ISO 15189:2007, is valid until 16.04.2016. Athens, January 09, 2015 Ioannis Sitaras Director of the Laboratories Accreditation Division Page 3 of 3 Annex G1/3 to the Certificate ESYD No.805 09.01.2015