Technical specification for supply the spare parts – task:” Supply MetOne instruments: rain gauges, wind speed and wind direction sensors”. Wind speed and wind direction sensors: LP 1. name Minimum requested parameter Wind Speer sensor (MetOne 60524 the same or better parameter – 16 psc. maximum operating range : 0-60m/s starting speed: 0,4 m/s accuracy: ± 1,5% temperature range: -50°do 85°C sensor: contact closure diameter: 25,5 mm, height 325mm material: aluminium sensor equipped with plug: MIL –E – QUAL ( CXS3106A14S6S ) plug wiring: A – power max. 12V B – GND D – HEATING E – HEATING Heating circuit- resistance for 24VAC, 12,5W power wind Speer sensor calibration characteristic: RPM ( obroty na minutę) F(Hz) 100 3,333 200 6,667 300 10,000 400 13,333 500 16,667 600 20,000 2. Wind Direction sensor MetOne 60525, the same or better parameter) - 16 psc. 700 23,333 800 26,667 900 30,000 1000 33,333 1100 36,667 1200 40,000 1300 43,333 1400 46,667 1500 50,000 1600 53,333 1700 56,667 1800 60,000 azimuth: 0-360° (electrical: 0-356°C) threshold: 0,4 m/s accuracy: ±5% sensor: varying resistance 0-10k ohms temperature range: -50°do 70°C diameter: 25,5 mm, height 325mm material: aluminium Heating circuit - resistance for 24VAC, 12,5W power sensor equipped with plug MIL –E – QUAL ( CXS3106A14S6S ) plug wiring: A – power max. 12V B – GND C – output D – heating E - heating Potentiometer needs to fulfill above standards: MIL – E – 5272 MIL – E – 12943 Chassis: easy to replace potentiometer Heated and unheated rain gauges. LP 1. 2. name Unheated rain gauge (MetOne typ 60030 the same or better parameter) – 32 psc. Rain Gauge Heated (MetOne typ 60030H the same or better parameter) – 32 psc. Minimum requested parameter orifice: 200 cm² sensor method: magnet&reed resolution: 0,1mm accuracy: ±1%, ± 0.1 mm ( amount < 5mm), ±0,2mm ( amount ≥ 5mm) ± 2% ( intensity ≥ 10mm/h) Sensor type: contact/switch closure weight: 1,1kg ( unheated), dimension: height: 312mm, diameter max. 168mm installation: base plate Leeds to have 3 instalation holes ( 6,5 mm diameter - -placed at the 125 mm diameter circle) sensor needs to be equip with two strainer ( small and big hole) against dirt and insect orifice: 200 cm² sensor method: magnet reed resolution: 0,1mm accuracy: ±1%, ± 0.1 mm ( amount < 5mm), ±0,2mm ( amount ≥ 5mm) ± 2% ( intensity ≥ 10mm/h) Sensor type: contact/switch closure weight: 1,5 kg ( heated), dimension: height: 312mm, diameter max. 168mm installation: base plate needs to have 3 installation holes ( 6,5 mm diameter - -placed at the 125 mm diameter circle) heating circuit - resistance 24 VAC – power: 175W – heating element under reed 25W , inside gauge ( 150W) sensor needs to be equip with two strainer ( small and big hole) against dirt and insect easy way to disconnect the gauge from base plate to take a service&cleaning Additional request: Bearings for actually in use by the orderer wind Speer sensor – ULKZ 8016X-48-A7P-12/20L21 ( part number: 01510563) – manufacturer part number 60524 - 128 pcs. Potentiometers for actually in use by the orderer wind Direction sensor - 6009-2140-430 – manufacturer part number 101444 – 65 pcs.