Kewill Imaging_Using Scanner Upload

advertisement
Kewill Imaging
Using Kewill Imaging Scanner Upload
Publication Date: August, 2008
Last Revision Date: July 28, 2008
Kewill Imaging
Table of Contents
Table of Contents..................................................................................................................................... 2
Using Kewill Scanner Upload ................................................................................................................. 3
Prerequisites ......................................................................................................................................... 3
Installing Kewill Imaging Scanner Upload ......................................................................................... 4
Configuring Kewill Imaging Scanner Upload .................................................................................... 5
Defining a Scan Folder ......................................................................................................................... 8
Controlling the Kewill Imaging Scanner Upload service ................................................................ 12
Finding the Kewill Imaging Scanner Upload Version ..................................................................... 14
Imaging-2
Copyright © 2008 Kewill plc
Kewill Imaging
Using Kewill Scanner Upload
Introduction
Kewill Imaging Scanner Upload is a Windows service for retrieving scanned
documents from file folders. The documents are stored in the Kewill Imaging
system for manual indexing under manual indexing work queues. Optionally,
metadata describing the documents can accompany them for automatic
indexing of the documents into the Kewill Imaging system.
Kewill Imaging Scanner Upload is installed on a Windows server.
Prerequisites
Overview of
Prerequisites
Before you install Kewill Imaging Scanner Upload, you must install the
following on the host Windows server: Full Oracle 10g client. To do so follow
the instructions below.
Step
Action
1
Copy file Oracle_10201_client_win32.zip from the Kewill Imaging distribution media to
the Windows server. Unzip the file, preserving its folder structure, to a temporary
directory on the Windows server.
2
Run SETUP.EXE in the client subfolder of the directory to start installation of the full
Oracle 10g client.
Select a Custom install.
When presented with a list of options to install, select all options.
3
After installation of the full Oracle 10g client is completed, you may need to change
setting SQLNET.AUTHENTICATION_SERVICES=(NTS)
to
SQLNET.AUTHENTICATION_SERVICES=(NONE) in file SQLNET.ORA,
depending on how Kewill Imaging Scanner Upload is connecting to the Kewill
Imaging database. This file is typically found in the NETWORK\ADMIN
subfolder of the Oracle 10g client installation directory.
4
In the same file, you may also need to comment out setting
NAMES.DIRECTORY_PATH= (TNSNAMES)
by changing it to
Imaging-3
Copyright © 2008 Kewill plc
Kewill Imaging
Step
Action
#NAMES.DIRECTORY_PATH= (TNSNAMES)
Installing Kewill Imaging Scanner Upload
Installation
Instructions
To install Kewill Imaging Scanner Upload on the Windows server, follow the
steps below.
Step
Action
1
Copy file KISU_n.n.n_install.zip from the Kewill Imaging distribution media to the
Windows server.
2
Unzip the file, preserving its folder structure, to a temporary directory on the Windows
server.
3
Run SETUP.EXE in the directory to install Kewill Imaging Scanner Upload.
4
Accept all defaults during installation.
If you are upgrading Kewill Imaging Scanner Upload, then you will be prompted for a
choice of Modify, Repair, or Remove; choose Repair.
Note: You must stop the Kewill Imaging Scanner Upload service before the upgrade.
5
After installation of Kewill Imaging Scanner Upload is completed, Kewill Imaging
Scanner Upload must be registered as a service in the Windows Service Control
Manager.
To do this, click the Kewill Imaging Scanner Upload Settings shortcut in the Kewill
Imaging Scanner Upload program group to display the Kewill Imaging Scanner
Upload Settings screen (sample below).
Imaging-4
Copyright © 2008 Kewill plc
Kewill Imaging
Kewill Imaging Scanner Upload Settings screen:
Kewill Imaging
Scanner Upload
Settings
Enter Windows account information in the Account section for the Windows
account under which you want the Kewill Imaging Scanner Upload service to
run.
Click the Install button to register it in Windows Service Control Manager.
The contents Status box should change from “Not installed” to “Stopped”.
Click the Cancel button to close the Kewill Imaging Scanner Upload Settings
screen.
Configuring Kewill Imaging Scanner Upload
Configuration
Kewill Imaging Scanner Upload is configured via its Settings screen and
Kewill Imaging System Manager.
Imaging-5
Copyright © 2008 Kewill plc
Kewill Imaging
You can access the Settings screen by clicking the Kewill Imaging Scanner
Upload Settings shortcut in the Kewill Imaging Scanner Upload program
group.
Kewill Imaging Scanner Upload Settings screen:
Kewill Imaging
Scanner Upload
Settings Screen
The Oracle Connection section defines the Kewill Imaging database that
Kewill Imaging Scanner Upload will communicate with. Typically, the
Database Name has the format ServerName:Port/SID. [Contact your Imaging
system administrator for this information].
Processing Interval is the time interval in minutes (>0) on which Kewill
Imaging Scanner Upload runs to retrieve scanned documents from file folders.
The Error Reporting section controls the logging of errors. Errors can be
logged to any combination of the following:


the Windows Application Event Log,
a specified Log File, and
Imaging-6
Copyright © 2008 Kewill plc
Kewill Imaging

a semicolon-delimited SMTP E-mail (user@domain) address list.
An e-mail is sent using SMTP. SMTP settings are defined in the SMTP Email
screen (menu item General/SMTP Email) in Kewill Imaging System Manager.
[Please refer to the Kewill Imaging System Manager User Guide for details.]
When you are finished configuring Kewill Imaging Scanner Upload, click the
OK button to save the configuration.
Scan Folders for Import Imaging and Export Imaging are defined via the
Tools/Import Folders… and Tools/Export Folders… menu items
respectively. These menu items display a Scan Folders screen (see below).
Scan Folders screen:
Scan Folders Screen

To add a Scan Folder, click the Add button.

To edit a Scan Folder, select it in the Scan Folders list and click the Edit
button, or double-click it.

To enable, disable, or delete one or more Scan Folders, select them in the
list and click the Enable, Disable, or Delete buttons respectively.

To redisplay the Scan Folders list, click the Refresh button.
Imaging-7
Copyright © 2008 Kewill plc
Kewill Imaging

To close the Scan Folders screen, click the Close button.
Defining a Scan Folder
Settings for a Scan
Folder
Settings for a Scan Folder are defined in the Add Scan Folder and Edit Scan
Folder screens [see sample screen below].
Add Import Scan Folder screen:
Field
Folder
Description
This is the location of the Scan Folder. It can be a local folder (e.g., c:\folder1) or a
network folder (e.g., \\server1\folder1).
The Windows account under which the Kewill Imaging Scanner Upload service runs
must have full access to the Scan Folder location.
Description
This field is an optional description for the Scan Folder.
Imaging-8
Copyright © 2008 Kewill plc
Kewill Imaging
Field
Description
Work Queue
This is the manual indexing work queue in Kewill Imaging where documents retrieved
from the Scan Folder will be stored.
Enabled
If Enabled is checked, then the Kewill Imaging Scanner Upload service will look in the
Scan Folder for documents; otherwise, it will ignore the Scan Folder.
Metadata
If Metadata is checked, then a metadata file is assumed to accompany the document
in the Scan Folder.
A metadata file contains information that describes one or more documents so that
they can be automatically be indexed into Kewill Imaging. It has extension .DAT and
can contain more than one metadata record. A metadata record is a line in the
metadata file that describes one document. The metadata record format is as
follows:
record-identifier | line-of-business | file-type | sub-type | document-type | entity |
alternate-entity | suffix | document-date-time | confidential | file-specification [ |
reference-number-type | reference-number-value ] [ | reference-number-type |
reference-number-value ] ...
where
record-identifier is the record identifier; it is always KI (for Kewill Imaging)
line-of-business is the line of business: I for Import, or E for Export
file-type is the storage area for the document:
For the Import line of business:
IC
Import Customer
IE
Import Entry
IM
Import Miscellaneous
IV
Import Vendor
For the Export line of business:
EAF
Export Air File
EAJ
Export Air Job
EC
Export Customer
EM
Export Miscellaneous
EOF
Export Ocean File
EOJ
Export Ocean Job
EV
Export Vendor
sub-type only applies to the IM and EM file types; it is the miscellaneous
sub-storage area and can be up to 20 characters; for all other File Types, it is
ignored.
document-type is a positive integral number that uniquely identifies each
type of document (e.g. 27 for a CBP 7501); it is analogous to the tracing date
code in Kewill Customs and can be up to 10 digits (1-9999999999);
document types are user-extensible via Imaging System Manager
entity is the identifier under which the document will be stored; its definition
depends on the File Type:
For the Import line of business:
File Type
Entity
IC
Customer code, up to 10 characters
Imaging-9
Copyright © 2008 Kewill plc
Kewill Imaging
Field
Description
IE
IM
IV
File Number, up to 10 digits (1-9999999999); can be
blank if alternate-entity is specified (see below)
Miscellaneous subtype identifier, up to 20 characters
Vendor code, up to 10 characters
For the Export line of business:
File Type
Entity
EAF
File Number, up to 8 digits (1-99999999)
EAJ
File Number, up to 8 digits (1-99999999)
EC
Customer code, up to 15 characters
EM
Miscellaneous subtype Identifier, up to 20 characters
EOF
File Number, up to 8 digits (1-99999999)
EOJ
File Number, up to 8 digits (1-99999999)
EV
Vendor code, up to 15 characters
alternate-entity only applies to the IE file type; in this case, it is the 11character Entry Number and can be specified in lieu of the entity (File
Number); for all other File Types, it is ignored.
suffix is the suffix of the document; it differentiates documents of the same
document type for a given entity; it can be up to 10 characters, and can be
blank.
document-date-time is the date and time of the document, in format yyyymm-dd hh:mm:ss
confidential is a flag that indicates whether the document is confidential: Y
for yes (confidential), N for no (non-confidential)
file-specification is the file specification (path and name) of the document
image file; if no path is specified, then the document image file is assumed to
reside in the folder where the metadata file resides
reference-number-type is an alphanumeric code, up to 20 characters, that
uniquely identifiers the type of reference number (e.g. CI for Commercial
Invoice Number); reference number types are user-extensible via Imaging
System Manager
reference-number-value is the reference number, up to 50 characters
Parameters in the metadata record are separated by the pipe character (|).
Reference numbers at the end of the metadata record are optional. More than
one can be specified. Both reference-number-type and reference-numbervalue must be present to describe a reference number.
If the document accompanying the metadata cannot be automatically indexed
because of invalid metadata or other problems, then the document will be stored
in the manual indexing work queue.
Maximum
Documents Per
Cycle
This defines how many documents the Kewill Imaging Scanner Upload service will
retrieve from the Scan Folder during a processing cycle.
Priority
This defines the order in which Scan Folders are processed by the Kewill Imaging
Scanner Upload service during a processing cycle; Scan Folders with the highest
Imaging-10
Copyright © 2008 Kewill plc
Kewill Imaging
Field
Description
priority will be processed first.
Resolution (DPI) The Resolution (DPI) defines how documents retrieved from the Scan Folder will be
resampled (resized to a new horizontal and vertical resolution) before being stored in
Kewill Imaging. Three resampling options are available:
Last Process
Date/Time
OK button
Cancel button
1.
Do Not Resample - No resampling of the documents is done.
2.
Max(X,Y) = Each document is resampled to a horizontal (X) and vertical (Y)
resolution that is the maximum of its original X and Y resolutions.
3.
(1 - 999) - Each document is resampled to the specified horizontal (X) and
vertical (Y) resolution. The specified resolution must be an integral number
between 1 and 999 inclusive.
This is the most recent date and time that the Kewill Imaging Scanner Upload service
retrieved documents from the Scan Folder.
To save settings for the Scan Folder, click the OK button.
To ignore settings for the Scan Folder, click the Cancel button.
Imaging-11
Copyright © 2008 Kewill plc
Kewill Imaging
Controlling the Kewill Imaging Scanner Upload service
Controlling the upload To control the Kewill Imaging Scanner Upload service, select the Kewill
service
Imaging Scanner Upload Settings shortcut in the Kewill Imaging Scanner
Upload program group. The Kewill Imagning Scanner Upload Setting screen
will display (see sample below).
Kewill Imaging Scanner Upload Settings screen:
Field
Start button
Description
Click the Start button to start the Kewill Imaging Scanner Upload service.
Imaging-12
Copyright © 2008 Kewill plc
Kewill Imaging
Field
Stop button
Pause button
Description
Click the Stop button to stop the Kewill Imaging Scanner Upload service.
Click the Pause button to pause the Kewill Imaging Scanner Upload service if it is
running.
Resume button
Click the Resume button to resume the Kewill Imaging Scanner Upload service if it is
paused.
Restart button
Click the Restart button to restart the Kewill Imaging Scanner Upload service.
Install button
Click the Install button to register the Kewill Imaging Scanner Upload service in
Windows Service Control Manager (See section Installing Kewill Imaging Scanner
Upload).
Uninstall button
Click the Uninstall button to unregister the Kewill Imaging Scanner Upload service
from Windows Service Control Manager.
Status button
Click the Status button to display the status of the Kewill Imaging Scanner Upload
service in the Status box.
Command-Line control The Kewill Imaging Scanner Upload service can also be controlled from the
command line.
Select the Kewill Imaging Scanner Upload Command-Line Help shortcut in
the Kewill Imaging Scanner Upload program group to display command-line
options.
Kewill Imaging Scanner Upload screen:
Imaging-13
Copyright © 2008 Kewill plc
Kewill Imaging
Finding the Kewill Imaging Scanner Upload Version
To find out what version of Kewill Imaging Scanner Upload you are using,
select the Help/About… menu item to show the About box:
Copyright © 2008 by Kewill plc
[last revision date: 08/06/08]
Imaging-14
Copyright © 2008 Kewill plc