Addendum - Sunshine Coast Council

advertisement
Standard Drawings Addendums
Std. Dwg. No.
Addendums to Standard Drawings for use in Sunshine Coast Council
GENERAL
GS-041 & 44
Black only PVC not green plastic, posts to be painted black
GS-042
Bollard detail excepted only - no log fence.
Where bollards are located adjacent to kerbside parking they should be a minimum of 800mm
back from the face of kerb.
Bollards should provide colour and luminance contrast to their surroundings, particularly if they
are adjacent to a pathway or disabled parking bays.
GS-045
Black posts/Black weld mesh or as specified by council.
MR 1603
Black only PVC not green plastic, posts to be painted black.
GS-011 & 012
Use SM3 kerb type and concrete backing strip of 200mm instead of the B6.
DRAINAGE
Inlet capacity charts are available on request without prejudice.
Designers need to allow for local conditions.
Maximum depth of pit is 1.8m.
DS-031
Lean mix concrete is not allowed within the pavement box.
DS-041
Straw bales not used.
DS-061
Use of VS (1200mm) lintel is acceptable.
ROADS
RS-065
Pathway widths - Access Street - minimum 1.5m - desirable 2.0m
- Neighbourhood - minimum 1.8m - desirable 2.0m
- District Collector - minimum 2.0m - desirable 3.0m
- Sub Arterial - minimum 2.5m - desirable 3.0m
- Arterial - minimum 3.0m - desirable 4.0m
- Cycleway Local 2.5m
- Cycleway Trunk 3.0m
CCS Black 21 (6% pigment) coloured trunk pathway 2.5m or greater.
RS-080
Kerb and Channel profiles to be used in this Council are as follows:
B1 – Design speed greater than 50km/h, channel invert width is 450mm – Main Streets, Park
frontages
B2 – where no stormwater flow
SM3 – Median kerb
M1 – Design speed up to and including 50km/h
ER2 – Edge restraint
INVERT – Stormwater drain inverts
All kerbs shall be constructed with plain concrete.
All kerbs shall be placed on a minimum 75mm thick gravel base that extends 150mm beyond the
back of kerb.
RS-090
Desirable kerb ramp grade is 1 in 15, achieve a best fit to a maximum of 1 in 8.
RS-091
Council only accepts cut-through treatments, width dimension x be a minimum of 2m.
Median paths to be plain concrete with black TGSI’s.
RS-0130
No Council logo.
RS-0131
Sign posts are to be installed using a spike foundation system. Sign posts in concrete are to be
installed using V-Sockets or Lock-Sockets.
PARKS
PS-010
Type 1 – Alternative treatment only.
PS-016
Rest rail accepted – no deflections rails.
Current as at 05/03/2015