Codes Specs without SW Specs with SW DL 3155M63 FIBER

advertisement
Codes
DL 3155M63
Specs without SW
Specs with SW
FIBER OPTICS - didactic equipment- auxiliary blocks for the analogue and
digital transmission: Microphone amplifier, Audio amplifier, Interface for
the 32-bit module, Data generator, TTL inputs, Manchester and Bi-phase
data coding, 660 and 820 nm led light source, PIN receiver, ST type
connectors, Optical fibres, Reception circuit with trans-impedance
amplifier. The following subjects are dealt with: Introduction to fibre
optics communication, Attenuation, Numerical openings, Propagation
methods, Transmitted power specifications, Chromatic and modal
dispersion, Cable attenuation specifications, Received power
specifications, Time division (TDM) and wave length division (WDM)
transmission. It must be possible to perform the following experiences:
Clock Signal Generator, Digital Input Output / POF Fiber, Digital Input
Output / ST Fiber, Analog Input Output / POF Fiber, Serial Interface / ST
Fiber. The faults must be inserted by microswitches; the module must be
provided with a EISA BUS 31+18, connections and test points by 2mm
terminals.
Dimensions of the module: 297x260mm.
The module must be supplied with a theoretical and practical manual.
FIBER OPTICS - didactic equipment- auxiliary blocks for the analogue and
digital transmission: Microphone amplifier, Audio amplifier, Interface for
the 32-bit module, Data generator, TTL inputs, Manchester and Bi-phase
data coding, 660 and 820 nm led light source, PIN receiver, ST type
connectors, Optical fibres, Reception circuit with trans-impedance
amplifier. The following subjects are dealt with: Introduction to fibre
optics communication, Attenuation, Numerical openings, Propagation
methods, Transmitted power specifications, Chromatic and modal
dispersion, Cable attenuation specifications, Received power
specifications, Time division (TDM) and wave length division (WDM)
transmission. It must be possible to perform the following experiences:
Clock Signal Generator, Digital Input Output / POF Fiber, Digital Input
Output / ST Fiber, Analog Input Output / POF Fiber, Serial Interface / ST
Fiber. The faults must be inserted by software and by microswitches. The
module must be provided with a EISA BUS 31+18 interface for connection
to power supply and with a software able to allow the study of theoretical
topics through PC with hyper textual navigation according to the HTML
standard. Connections and test points by 2mm terminals.
Dimensions of the module: 297x260mm.
The module must be supplied with a theoretical and practical manual.