JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA TENDER NOTICE JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA , KAKINADA – 533 003, A.P. No. JNTUK/IST/Schools/Equipment /2014 Date: 09.08.2014 Sealed tenders are invited from reputed Dealers/Suppliers for the supply of the Lab equipment for various Schools under IST, JNTUK, Kakinada. The details can be downloaded from www.jntuk.edu.in Sd/- Registrar 1 JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA Tender Notice No. JNTUK/IST/Schools/Equipment/2014 Dt: 09.08.2014 TENDER SCHEDULE 1. GENERAL CONDITIONS: Please quote your lowest rates for each item described. The quotation should reach this office on or before 26.08.2014 by 5:00 p.m. Sealed covers should be submitted for the items super scribing as “Tender No.”, “Date of opening:”, “Item Number(s)”. The sealed covers should be sent by the Registered Post or to be dropped in the sealed box provided in the office of the Registrar. The tender will be opened on 27.08.2014 at 10:30 a.m. by the undersigned/his nominee in the presence of the committee members and available tenderers’ or their representatives. The tenderers who submit the quotations along with a DD for 1,000 drawn in favor of The Registrar, JNTUK Kakinada payable at Kakinada are only eligible to participate in the tender. 2. E.M.D: The tender documents should be submitted along with earnest money deposit 10,000 in the form of Demand Draft in favor of The Registrar, JNTUK Kakinada payable at Kakinada. The Demand Draft pertaining to E.M.D. of unsuccessful party will be returned. 3. PRICES: The price should be quoted in Indian Rupees only and F.O.R. destination inclusive of taxes, packing & forwarding charges, freight and delivery chargers. Items on rate contract, if any together with the terms and conditions may please be furnished. 4. PAYMENT: 100% payment will be made within a reasonable time only after the receipt of all items in good condition and installation as per given specifications and after testing for satisfactory working and on receipt of the company’s invoice with all supporting vouchers such as copy of A.P. Sales Tax or VAT Registration certificate etc. No advance will be paid in any case either in part or in full. 5. JNTUK, Kakinada has been registered with DSIR, GOI and exempted from customs and central excise (copy of the certificate enclosed). 6. ACCEPTANCE: It is not binding on the university/ institution to accept the lowest of the tenders. The university/ institution reserves the right to place orders for individual items with different tenderers. 2 7. SPECIFICATIONS: Full specifications along with the description and MAKE should be mentioned in the tender. 8. Warranty/Guaranty: tenderer. 11. DELIVERY: The period of delivery at destination from date of placing orders is 6 WEEKS. 12. VALIDITY: The quotations should be valid for at least 180 days. 13. The Institution reserves the right to cancel the tender without assigning any reason. 14. This University being Government educational institution is exempted from payment of Central/State Excise Duty. 15. Since the college is Government institution whatever conditions are applicable to any Government institute shall be applicable even if not specified. 16. Any tender that is received after due date will not be accepted. The university is not responsible for any postal delay. 17. Attach the List of Major Customers along with the tender. 18. Any specific queries, communications, and references should be made only to, The Registrar, JNTUK, Kakinada. Warranty/Guaranty period should be mentioned by the Sd/Registrar Encl: Items with Description. 3 Institute of Science & Technology, JNTUK, Kakinada Specifications of the items for School of Avionics Item No. A-1 Name Avionics Data Bus Product : MIL-STD-1553B interface card Specifications USB based 2 channel card Supporting BC, multiple RT and MT functions with casing/ enclosure Accessories (2 sets ) Each set contains - Quantity 2 2 port and 4 port bus couplers (1 each) 1553 transformer coupled I/O cable with PL-75 connectors (3 ft) Bus termination (1) USB cable with screw locks (5ft) D type mating connector (1) User Manuals, driver software and demo programs. A-2 Avionics Data Bus Product : ARINC-429 Interface card USB based 4Rx/2Tx interface card with casing/enclosure Accessories (2 sets) Each set contains - USB cable with screw locks (5ft) D type mating connector User Manuals, driver software and demo programs. 4 2 Institute of Science & Technology, JNTUK, Kakinada Specifications of the items for School of Renewable Energy & Environment Item No Name Specifications Quantity Renewable Energy – Simulation Lab E-1 Software: ANSYS 15.0 Applicable to Energy – Electromagnetics – Industrial equipment & Rotating Machinery – CFD solutions Modeling, simulation, and analysis – Professional - Licensed software 3 user E-2 Software: CATIA V6 3D Applicable to solar, wind, wave etc. Renewable Energy Systems - Product Development Modeling and design Professional – Licensed software 3 user 5 Institute of Science & Technology, JNTUK, Kakinada Specifications of the items for School of Health Science & Research Item No. H-1 H-2 Name MOBILE X-Ray PORTABLE SPIROMETER Specifications GENERATOR: DSP Controlled, High Frequency 4Kw INPUT VOLTAGE : 185 V – 260 V, Single Phase AC, 50Hz KV RANGE : 40 kV to 100c kV in steps of 1kV mA Range : 10mA to 100 mA, mAs range : 0.1 mAs to 250 mAs Exposure time : 10 msec to 10 sec Indicator and controls : set kV, set mAs, exposure ready & fault X ray tube : stationary anode tube Focal spot : 1.8 IEC 60336 Collimator : 160 lux at 1m from focal spot, 30 sec auto light off Maximum x ray field : 480mm X 480mm at 1m from focal point Tube head vertical rotation : <290 degrees Tube head horizontal rotation : 360 degrees Collimator rotation :-90 degree to + 90 degree FVC, SVS AND MVV TESTS Pre and post medication results Internal memory for 2500 tests Auto interpretation Battery status indicator PC connectivity for further viewing , reporting and management of data Technical specification: Flow meter : -10 to + 16 liters Max volume 8 lts Accuracy ± 1% Tranducer bielectrical turbine cartridge Turbine sensor infrared interruption Flow detection volume differential Data display Graphs & measurements Graphics Display 320x240 pixels Power supply Line power ~ 220 -240 V, 50Hz + 10 % Power supply AC/DC Battery 12V/1.2 AH PC mode Communication interface USB Features PC based spirometer, data download facility, 6 Quantity 1 1 OPTIONAL Disposable mouth pieces PC/laptop, Desk Jet/Laser Jet Printer H-3 H-4 H-5 PULSE OXIMETER TRANSCUTANE OUS ELECTRICAL NERVE STIMULATOR BATH TUB (STANDARD) High brightness led display of NIBP,SPO2 and pulse rate Memory: built in flash memory Visual and audio alarms, adjustable Built in lithium ion battery Suitable for adult, pediatric and neonatal patients Specifications NIBP Method : oscillatory Mode :manual / automatic/ continuous Measurement range 25 – 260 mm Hg Resolution 1mm Hg NIBP Accuracy ± 5mmHg Alarm: Systole/Diastole/Map spO2 Measurement range 0% to 100% Resolution 1% Accuracy ± 2% (70% - 100%) Alarm range 0 – 100% Pulse rate Measurement range 10 – 270mmHg Resolution 1bpm Accuracy ± 2 bpm : Dual , Isolated between Channels MODE OF OPERATIONS : Burst, Continous, Modulation PULSE INTENSITY : Adjustable 0 – 80 Ma peak into 500 ohm PULSE RATE : 2 Hz to 150 Hz PULSE WIDTH : 30 uS to 260 uS Wave forms : Asymmetrical, Bi phasic square pulse Voltage : 0 -100 volts Power supply : 9 volts battery 1 CHANNEL Capacity 68 gallons Dimensions : 48 inch Length X 32 inch width X 25 inch height High glass acrylic surface Smooth touch backing Built in screw guides 7 3 1 H-6 HEAMATOLOGI Technical Specifications: CAL ANALYSER Function: Automated WBC 3-differential, 25 parameters with 3 color histograms (WBC, RBC, PLT). Principal: Electronic impedance, SFT method for haemoglobin. Parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, LYM%, LYM#, GRA%, GRA#, MID%, MID#, PDW, MPV, PCT, RDW-CV, RDW-SD, PLCR, RCDW, LCDW and WBC, RBC, PLT three histograms. Throughput: HL-3124≥30T/H; HL-3124≥60T/H. Analysis Mode: Optional venous blood, anticoagulant blood and prediluted blood. Sample Volume: Anticoagulant whole blood ≤9.6µL, Anticoagulant capillary blood ≤9.6µL, prediluted capillary blood ≤20µL, the sample volume for repeating two times testing and avoiding second sampling. Automated Maintenance: Automated washing during power on and power off, reducing the blockage rate. Storage: Large quantity test results storage, at least 400 thousand test results with comprehensive information. Extended SD memory supported. Control Mode: Quality control mode of L-J, X-B and X-r. Westguard quality control regulation. Calibration Mode: Manual and automatic calibration available. Fresh blood calibration available also. Discriminator Function: Float and fix discriminator. Manual adjust available Display: TFT LCD Touch Screen Input Mode: Standard mouse and keyboard. Optional bar code reader Print Mode: Internal high-speed thermal printer. Optional connection with specified external printer. English printouts. 8 1 H-7 H-8 PROFESSIONAL MULTI Features PROGAM All information is displayed on a Profile Matrix TREAD MILL LED display console Feedback includes elevation, heart rate, time, speed, calories and distance Console: Profile matrix LED display 3-Window LED Display Console feedback: Elevation Heart rate Time calories Speed Distance LACTATE ANALYSER Programs: 22 Manual Walking courses 3 Running courses 3 Cardio 3 Heart rate control 2 Custom learn 3 Fat burn 3 Endurance 3 Interval Specifications: Power: 110 volts 60 hz Motor: 3.0 hp continuous duty Run belt: 19.5in x60in Running area: 19.5in x60in Rollers: 2.5in Motor control: PMW system Speed: 0.5 to 10mph Elevation: 0-15% 960 joules thrust motor Cushioning: 8-point elastomer system Floor space: 82in x 31in Weight capacity: 210 kg Method : Enzymatic oxygen rate Sensor : Clark-type amperometric oxygen electrode Reaction temperature 30 °C Display : 32 character backlit LCD Printer : 16 column dot matrix, 1 line/sec. Statistics Sequential, giving mean, S.D &C.V. Interface :Serial data port, optional Windows software Power : 100 -250 V AC, 12- 15 V DC, 60 VA 9 1 1 H-9 BIOCHEMISTRY ANALYZER ANALYTICAL PERFORMANCE Precision :CV OF 2 % @ 2.5MMOL/L Accuracy : Method comparison for whole blood vs YSI 23L: y (Analox) = 0.98x + 0.055 mmol/L, r = 0.9991, n = 56 Linearity : 10 mmol/L (ca. 90 mg/dl) for 7 µl samples Features Analytical Modes: kinetic, fixed time, end-point, absorbance Wavelengths:7 standard filters:340,405,492,510,546,578,630nm,1 more filter optional Full open reagent system Items can programmed, number of items not limited Voice prompting, making the operation interesting Windows operation interface, figure button, mouse operation Real time graph display and print Lamp saving feature, longer lamp life Large storage ability, up to1000,000 results Technical Specifications Assay Method: reaction rate, endpoint, two-point, double wavelength, coefficient, multiple standards, blank reagent, blank sample, absorbance at fixed point, Q.C, Q.C graph and turbidity Temperature System: PELTIER temperature control component, 25,30,37deg,accuracy: ±1deg Light Source: 6V, 10W halogen lamp of more than 2000 hours’life time GML Precision:±2nm FWHM: ≤10nm Stray Light:≤0.5%(absorbance≥2.5) Absorbance Range:-0.214~3.000 Absorbance Linearity:±1% Absorbance Repeatability:±0.001 Precision: ≤1% Carry Over: ≤1% Resolution: 1m Abs Stability: ≤3mAbs/h Flow Cell: permanent quartz flow cell, minimal volume is 32uL,and disposable flow cell is selectable Sampling System: pressure auto releasing pumps ensure the accuracy of suction volume Absoption Volume:200uL~3000uL Sample Volume:10uL~50uL 10 1 H-10 TRAVELLER EEG Operational System: Windows XP with 1GB memory capacity Display:10.1’LCD Print: print standard test A4 test report Interface:RS-232 serial port Working Condition:Temperature:10-30deg,Relative Humidity:20%-80% Voltage: AC 85~264V,auto adapt according to the input voltage Power: ≤100W Quality System: CE General Electrical EEG Size : 192 (L) x 136 (W) x 42 (H) Weight : < 420 g No. of Input Channels : 24 No. of Display Channels : 24 Photo Stimulator : High intensity white LEDs Power Supply : USB Powered Frequency Band Range : 0.1 to 100Hz Input Impedance : > 10 M Noise : < 1uV P-P Input Range : ± 8 mV CMRR : >95 dB Sampling : 1024 Hz for at ADC, 256 Hz for internal storage A/D conversion : 16 Bit Impedance Measurement : Automatic, built-in Yes High Cut Filter (digital) : 0.5 - 100Hz Low Cut Filter (digital) : 0.1 - 7Hz Notch Filter (digital) : 50/60 Hz Time Resolution : 7.5, 15, 30, 60 mm/s Flash Rate : 1 - 60Hz Operating Environment Standard Accessories Optional Accessories 0 Temperature : 5 to 45 C Humidity : 5 to 95% RH (noncondensing) 0 Storage Temperature : 0 to 50 C Respiration Card 1 No. Electrodes Placement Card 1 No EEG Paste 2 Jars EEG Electrodes 50 Nos. ECG Electrodes 2 Nos. EMG Electrodes 2 Nos. Photic Flash 1 Nos. Photic Flash Flat Cable 1 Nos. 11 1 H-11 ECG USB Cable 1 No. Patient Ground Cable 1 No. Event Marker 1 No. User Manual 1 No. Head Box. 1 No. Camera Capture Card Audio Cable Signal Power Supply Cable General Size : 216mm (L) x 147mm(w) x 61 (H) Weight : < 820 g PC Communication Serial Interface RS 232 interface for data management and ECG viewing/reporting (ECG PC link software optional) Electrical Recharge Time : 3 to 4 hours for fully discharged battery Battery 7.4V- 2.2Ah Li-ion can give more than 50 ECG recordings on a single charge ECG Input impedance : > 10 MΩ on each electrode Leads : Standard/ Cabrera CMRR : > 90 dB Dynamic Range : ± 4.25mV Frequency Response : 0.05-150 Hz (-3dB) without filters Time Constant : 3.2 Seconds A/D Conversion : 12 bits, 12 leads simultaneous acquisition Sampling Rate : 1600 samples/sec/channel Paper Speed : 5, 25, 50 mm/sec 106 mm wide thermal paper in 20mm roll Sensitivity : 5,10, 20 mm/mV Filters Complete digital processing to reduce mains interference, muscle tremors & base line wander LED Indicators Mains connected, low battery, No Paper, loose electrode Paper Memory 10 seconds for all 12 leads. Multiple patients (Optional) Power Supply : 12 V, 1 A DC Adapter Defibrillation protection : Internal at apparatus Pace maker detection : ≥ ± 2mV/≥ 0.1 ms Printout : 4/6 Channel options Flexible reporting Reports of stored ECG can be copied for print with new Selection Of filters, speed and sensitivity. 12 1 H-12 PC Audiometer Operating Environment Temperature 0 to 45 C Humidity 5 to 95% RH, non-condensing. Storage 0 to 55 C Standard accessories Patient cables 1 Nos Gel bottle 1 Nos Limb electrodes 4 nos Chest electrodes 6 nos Carry bag adapter Optional accessories Pediatric electrodes Rechargeable battery Power Supply : Built in power supply. 100-240V, 5060Hz, Max 0.7 A Display : 8.4 inch high resolution color display, 800 x 600 pixels CALIBRATION : Air Conduction TDH39: ISO 389-1 1998, ANSI S3.62010 DD45: PTB/DTU report 2009 HDA200: ISO 389-8 2004, ANSI S3.6-2010 HDA280 PTB report 2004 E.A.R Tone 3A/5A: ISO 389-2 1994, ANSI S3.6-2010 BONE CONDUCTION : Placement: Mastoid Transducers :TDH39 Headband Static Force 4.5N HDA280 Headband Static F E.A.R Tone 3A/5A: CIR 33 PATIENT RESPONSE SWITCH :Two push button. PATIENT COMMUNICATION :Talk Forward (TF) and Talk Back (TB). Special tests/test battery : Stenger ABLB Langenbeck (tone in noise). Masking Level Difference Pediatric Noise Stimuli Multi Frequency High Frequency Speech from Hard-drive (Wave Files) SISI ,Master Hearing Aid ,Hearing Loss Simulator ,QuickSIN(tm), Auto threshold: o Hughson Westlake o Békésy 13 1 TONE :125-20000Hz separated in two ranges 1258000Hz and 8000-20000Hz. Resolution 1/2-1/24 octave. Pediatric Noise : The bandwidth is frequency depended 125-250 Hz 29%, 500Hz 24%, 750 Hz 20%, 1kHz 17%, 1.5kHz 13%, 2kHz 11%, 3kHz 9% from 4kHz Wave file :44100Hz sampling, 16 bits, 2 channels Warble Tone :1-25 Hz sine.1 to 25% modulation with ½dB step MASKING: Automatic selection of narrow band noise (or white noise) for tone presentation and speech noise for speech presentation. Narrow band noise: IEC 60645-1 2012, 5/12 Octave filter with the same centre frequency resolution as pure Tone. White noise: 80-20000Hz measured with constant bandwidth Speech Noise. IEC 60645-2:1993 125-6000Hz falling 12dB/octave above 1KHz +/-5dB Frequency range :125Hz to 8kHz (Optional High Frequency: 8 kHz to 20 kHz)125Hz, 250Hz, 750Hz, 1500Hz and 8kHz may freely be deselected SPEECH : Frequency Response: (Typical) Frequency Linear [dB] Ffequv [dB] [Hz] Ext. Sign1 Int. Sign2 Ext. Sign1 Int. Sign2 TDH39 (IEC 60318-3 Coupler) 125-250 +0/-2 +0/-2 +0/-8 +0/-8 250-4000 +2/-2 +2/-1 +2/-2 +2/-2 4000-6300 +1/-0 +1/-0 +1/-0 +1/-0 DD45 (IEC 60318-3 Coupler) 125-250 +0/-2 +1/-0 +0/-8 +0/-7 250-4000 +1/-1 +1/-1 +2/-2 +2/-3 4000-6300 +0/-2 +0/-2 +1/-1 +1/-1 E.A.R Tone 3A (IEC 60318-5 Coupler) 250-4000 +2/-3 +4/-1 (Non linear) B71 Bone Conductor (IEC 60318-6 Coupler) 250-4000 +12/-12 +12/-12 (Non linear) 14 2% THD at 1000 Hz max output +9 dB (increasing at lower frequency) Level range: -10 to 60 dB HL o Ext. Sign: CD input 2. Int. Sign: Wave files Free Field output (non-powered) :Power amplifier and loudspeakers With an input of 7 Vrms – Amplifier and loudspeakers must be able to create a Sound Pressure Level of 100 dB in a distance of 1 meter – and meet the following requirements: Frequency Response 125-250 Hz +0/-10 dB 250-4000 Hz ±3 dB 4000-6300 Hz ±5 dB Total Harmonic Distortion 80 dB SPL < 3% 100 dB SPL < 10% INTERNAL STORAGE :1000 patients and 50.000 sessions/measurements/audiograms Signal Indicator(VU) :Time weighting: 300mS Dynamic range: 23dB Rectifier characteristics: RMS Selectable inputs are provide with an attenuator by which the level can be adjusted to the indicator reference position(0dB) DATA CONNECTIONS FOR CONNECTION OF ACCESSORIES : 4 x USB A 1 x USB B for PC connection (compatible with USB 1.1 and later) 1 x LAN Ethernet EXTERNAL DEVICES (USB): Standard PC mouse and keyboard (for data entry) Supported printers: Please contact local distributer for a list of approved PC printers. INPUT SPECIFICATIONS: TB 212 uVrms at max. Gain for 0dB reading Input impedance : 3.2Kohm Mic.2 212 uVrms at max. Gain for 0dB reading Input impedance : 3.2Kohm CD1/2 16mVrms at max. Gain for 0dB reading Input impedance : 47Kohm TF (side panel) 212uVrms at max. Gain for 0dB reading Input impedance : 3.2Kohm TF (front panel) 212uVrms at max. Gain for 0dB reading Input impedance : 3.2Kohm 15 Wave files Plays wave file from internal SD card OUTPUT SPECIFICATIONS: FF 1/2/3/4 Line output 7Vrms at 2Kohms load 60-20000Hz -3dB FF 1 / 2 / 3 / 4 – powered 4x20W (only 2x20W can be used by software at the moment) Left & Right 7Vrms at 10 Ohms load 60-20000Hz -3dB Ins. Left & Right 7Vrms at 10 Ohms load 60-20000Hz -3dB HF Left & Right 7Vrms at 10 Ohms load 60-20000Hz -3dB HLS 7Vrms at 10 Ohms load 60-20000Hz -3dB Bone 1+2 7Vrms at 10 Ohms load 60-20000Hz -3dB Ins. Mask 7Vrms at 10 Ohms load 60-20000Hz -3dB Monitor headset (side panel) 2x 3Vrms at 32 Ohms / 1.5Vrms at 8 Ohms load 60-20000Hz -3dB Assist Mon. Max.3.5Vrms. by 8 Ω load 70Hz-20kHz ±3dB OPERATION ENVIRONMENT: Temperature: 15-35°C Re. Humidity: 30-90% Non condensing Ambient pressure: 98-104 kPa TRANSPORT AND STORAGE : Transport temperature: -20-50°C Storage temperature: 0-50°C Re. Humidity: 10-95% Non condensing 16 Institute of Science & Technology, JNTUK, Kakinada Specifications of the items for School of Pharmacy Item No. P-1. P-2. Name Specifications 1. Binocular Microscopes with Battery backup 2. Total Magnification 40X – 1000X 3. Viewing Head: Compensation free Binocular side and top of head at 30°-360° rotatable. 4. Eye Piece: WF 10x 5. Nose piece: Quadra pole Nose piece Binocular 6. Objectives: Achromatic objectives 4x,10x,40x,100x,999(oil) Microscopes 7. Focus: Co – Axial coarse and fine adjustment 8. Stage: Double layer mechanical stage 140x140mm, moving range 75x50mm 9. Illumination: LED light with battery back up. 10. Condensor: Abbe type NA 1.25 with IRIS Diaphragm and Filter 1. UV – 3000+ Double Beam UV - VIS Spectrophotometer with variable Slit width 0.5 to 5 nm with Automatic 8-Cell Changer and UV-WIN Software. Includes 4 Pairs of quartz cell 10 mm. Supplied with the following: a). Microprocessor based, high resolution LCD display and soft keypad - for operation on 220V/50Hz. b). Complete control through PC with UVWIN Software c). Double Beam optics with holographic grating in Czerny-Turner mounting, Monochromator High Double Beam UV intensity Tungsten Halogen and Deuterium lamp Visible with automatic changeover. d). High sensitivity matched pair Silicon Spectrophotometers Photodiode detector. Compliance with all Pharmacopoeia requirements. e). Built in validation program diagnostic and security functions. f). Upgradability option: System can be any time upgradeable to Peltier & Sipper attachments g). Operational modes:i) Standard Photometric ii) Quantitative iii) Spectrum scans iv) Kinetics [Enzymatic] Studies v) DNA and Protein. h). UV-Win software adds functions such as 3D Spectrum analysis, GLP/GMP/Pharmacopoeia 17 Quantity 20 03 P-3. P-4 IC.FR protocol. i). Large Sample compartment compatible with wide range of accessories . j). Scan Speed: Very Slow, Slow, Medium & Fast in the software. k). Compact design with small footprint l). first & second order derivatization m). Dust Cover for the main instrument. n). 5 KVA Servo Stabilizer with surge suppressor. o). Branded PC with 17” TFT Monitor & Laser Jet Printer -Parameters: Max.27 Whle Blood Parameters; 7 Body fluid reportable parameters; DC,WBC,RBC,HGB,HCT,MCV, MCHC,RDWCV, RDW-SD, PLT, MPV, PDW, PCT and Histogram for WBC, RBC, PLT, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran% Cell Counter (Auto Throughput: 60 samples per hour Hematology Analyzer) Sample volume: closed mode - 40µl Display: Color LCD display Printout: Thermal recorder, 50mm width paper, multitude of printout formats, printer optional Operating Environment: Temperature: 10º C~35º C Humidity: 20% ~85% 22 cpm A4 and 10 cpm A3 mono copier. Optional GDI printer functionality 32MB RAM for full digital functionality Time to first copy: 5.9 seconds from power on Fastest in class warm up time of 20 seconds Optional duplex Scanning Paper capacity of up to 1,250 sheets Long life components, easy maintenance Copy features: Auto reduction/enlargement, Booklet creation, Edge erase, ID Card Copy, Image shift, Invert image, Margin shift, Mirrored Photocopier image, N-up, Negative image, Reduce/Enlarge, Scan once-print many, Stored job setting, Touch screen interface Reduce/Enlarge: From platen: 25 – 400 % From document handler: 25 – 400 % Reduce/Enlarge increments: 1 % All-round functionality: copying, printing, scanning and faxing Sharp and high-quality colour output with new PXP toner Excellent productivity at 20ppm in both colour and B/W 18 01 01 Institute of Science & Technology, JNTUK, Kakinada Specifications of the items for School of Nanotechnology Item No. N-1 Name Spectrophotometer Specifications It should be capable of measuring with sample volume – 0.5μl to 1ul, Absolutely no cuvettes, capillaries or TIPS or plates or Membrane format for micro volume They should be provision to use cuvettes for 20 ul ,1 ml, 1.5 ml, 3 ml with heating facility and stirrer rpm 150-850 Should have long path length of 1 mm And should be having short path length (for high concentration measurement) of 0.05mm Technology should be Open system Should be capable of measuring 50-60 times more concentrated samples than normal spectrophotometer Detector: 2048-element linear silicon CCD array Absorbance Accuracy: 2% (at 0.76 absorbance at 257 nm) Sample Pedestal Material of Construction: 303 Stainless Steel & Quartz Fiber Absorbance Range: 0.02-300 (10mm equivalent absorbance) Wavelength Range: 190-840 nm Light Source: pulsed Xenon flash lamp Measurement Cycle should not exceed more than 10 seconds 100% sample recovery with no contamination. Simple and easy sample cleaning facility should be available System should not require any adaptors or any other accessories while taking readings. 19 Quantity 1 N-2 Differential scanning calorimeter (DSC) Detection limit: Upper limit - ds DNA 15000ng/μl, Lower limit - ds DNA 2ng/μl Software Nuclic Acids: ds DNA,ss DNA, RNA Protein: Bradford, Lowry, BCA, BSA, IgG, Lysozyme, Micro Array: Cell Culture General UV/Vis Software tool: System diagnostic tool. Instruments are approved to CE and UL/CSA standards. System should be quoted with 5 years warranty, and 1 pair of Quartz cuvettes of all sizes at free of cost. Temperature range : - 150 °C to 725°C Temperature accuracy : 0.1 °C Temperature precision : 0.1 °C Heating rate : 0.1 to 200°C / min in 0.1° interval Sensitivity : < 0.5 µW Stability : < 1 m W ambient to 550°C Principle: Heat Flux Plate Heat flux plate material : Chromel or Constantan Sample and reference thermocouples : Chromel/Alumel (Type K) Furnace thermocouple : Type K Typical rate : 5 to20°C /min Purge Gas Flow: Up flow Heating rate(℃/min): 0.1 to 200 Standard Cooling system: Water Cell design: Triple cap covering Cell material: Silver Should be capable to analyze · Glass transition · Melting points · Crystallization time and temperature · Boiling points · Thermal stability · Purity · Degree of cure · Rate of cure · Oxidative stability · Heat of fusion 20 1 · Heat of reactions · Heat capacity · Effects of additives · Polymer blends · Effect of recycled materials Multi-Data Analysis & Acquisition System Real-time color display of data collection Auto and manual scaling Time vs Temperature profiles First and second order derivative plots Analysis save feature Background data collection On-line help manual Individual segment display Annotation and drawing tools Copy to clipboard function Post collection editing Multiple curve/module overlay Split screen zoom mode Quadratic temperature and ordinate correction ASCII export Data smoothing Baseline file subtraction Y-axis shift operation Subfile operations Custom display configuration User selectable units Accessories : * Al Hermetic (Encapsulating) Sample Pans for Liquid Sample (Box of 200), should be used below 600℃. * Al Hermetic(Encapsulating) Sample Pan Lids with Pin Hole (Box of 20), should be used when the sample is vaporized during the experiment *Al Non-Crimping Sample Pans (Box of 200) , should be used at below 600℃. *Al Crimping Sample Pans , Cu Sample Pans for High Temperature (Box of 200), should be used up to 725℃; Pt Sample Pan for High Temperature, 1ea , should be used up to 725℃ 21 EXCISE DUTY EXEMPTION – ANNEXURE – IV 22 23