- Jawaharlal Nehru Technological University

advertisement
UNIVERSITY COLLEGE OF ENGINEERING
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA
KAKINADA– 533 003. Andhra Pradesh
Tender Notice No. JNTUK/DAP/UCEK/HSS-2015
Date 23/09/2015.
Sealed Tenders are invited for the supply of Lab Equipment/Furniture for Dept. of HSSVisit
www.jntuk.edu.infor details. Last date for receipt of tenders is 07/10/2015, at 03:00PM.
PRINCIPAL
UNIVERSITY COLLEGE OF ENGINEERING
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA
KAKINADA– 533 003. Andhra Pradesh
TENDER NOTICE
Tender Notice No. JNTUK//UCEK/HSS/2015
Date: 23/9/2015.
Sealed Tenders are invited from reputed Manufacturers/ Suppliers for the supply of the listed
items. The detailed specifications, terms& Conditions for the items can be downloaded from the
jntuk.edu.in. The sealed tenders should reach the undersigned on or before 07/10/2015, 03:00 P.M.
JNTUK reserves the right to accept or reject any or all bids without assigning any reason
whatsoever.
PRINCIPAL
Terms and Conditions:

The sealed tenders, mentioning clearly “ENGLISH COMMUNICATION LABORATORY” on the
cover along with the Tender No., Name of equipment, should be addressed and delivered to:
The Principal
UCEK,JNTUK, Kakinada
Kakinada – 533 003
Andhra Pradesh








Separate tenders should be submitted for each item as per the specifications mentioning with the
additional features, if any.
The completely filled in tender documents must reach the Principal, UCEK, JNTUK, Kakinada, on or
before 07/10/2015 at 03:00 P.M.
The tender will be opened on 07/10/2015 at 04:00 P.M. by the undersigned/his nominee in the presence
of the committee members and available tenderers or their representatives.
The tenderer shall be responsible for the delivery of the material, its successful demonstration, and
onsite training.
A Demand Draft for Rs.1000/- (Rupees One Thousand Only) drawn in favor of the “Principal, UCEK,
JNTUK, Kakinada” towards application fee (non-refundable) must accompany the tender(s) from each
tenderer.
A Demand Draft for an amount of Rs.10,000/- in case of furniture and Rs. 5,000/- in case of equipment ,
drawn in favor of the “Principal, UCEK, JNTUK, Kakinada” towards refundable EMD must also
accompany the tender. The tender without EMD will be rejected. The EMD for the unsuccessful
tenderers will be refunded.
UCEK, JNTUK, Kakinada has been registered with DSIR, GOI and exempted from customs and central
excise (copy of the certificate enclosed).
Suppliers of Lab/office furniture should have the following:
1. Own factory
2. ISO certification for production/certification/testing/environmentaletc.
3. BIFMA / FIRA/ OHSAS/SEFA/ASHRAE certification

Layouts of Lab. are enclosed. Supplier may visit Dept. of Humanities and Social Sciences to inspect the
proposed laboratory before submitting their offer.
 The prices should be inclusive of packing, forwarding, insurance, delivery at destination site and all
taxes (FOR Kakinada).
 The tenders should be valid for acceptance up to a period of 3 months. The tenderers should be ready to
extend the validity, if required.
 The Tenderer should produce copy of service Tax Certificate and PAN Card.
 Tenderer should enclose their offers with full details of equipment with full documentation / descriptive
literature / leaflets indicating special features of their equipment or systems.
 Tenders submitted after due date/time will not be considered and no intimation will be sent in this
regard.
 ThePrincipal, UCEK JNTUK, Kakinada does not bind himself to accept the lowest bid on any tender
and reserves the right either to select or reject certain item (single or multiple units) in the schedule
without assigning any reasons whatsoever. Acceptance of the tender shall be communicated by letter of
acceptance or formal acceptance of the tender to the successful tenderer.
 Any specific queries, communications, and references should be made only to, The Registrar, JNTUK,
Kakinada.
PRINCIPAL
LAB EQUIPMENT
UPS SPECIFICATIONS FOR 10 KVA (2 No’s)
90 MINUTES BACKUP:
Output Waveform
Line Mode
Overload
Capacity
BAT Mode
10000VA/9000W
110 ~ 276VAC
110 ~ 276VAC
45Hz ~ 55Hz / 54Hz ~ 66Hz
Single Phase with Ground
≥0.99 @ R Full Load
200VAC/208VAC/220VAC/230VAC/240VAC
<1%
45Hz ~ 55Hz / 54Hz ~ 66Hz
50/60 ± 0.05 Hz
3:1
≤2% @ Linear Load
≤5% @ Non-Linear Load
Pure Sine Wave
2min @105% ~ 125% load
30s @ 125% ~ 150% load
1s @ >150% load
EFFICIENCY
PARALLEL
Line Mode
BAT Mode
ECO Mode
Rated Battery Voltage
UP to 4
>92% @ Full Load and Battery Fully Charged
>92% @ Full Load and 12Vdc/Battery
>96% @ Full Load and Battery Fully Charged
240VDC
BATTERY
Recharge Time
CAPACITY
INPUT
VA/W
Acceptable Input Voltage
Adjustable Bypass Voltage
Frequency Range
Phase
Power Factor
Voltage
Voltage Regulation
Frequency ( Synchronized Range )
Frequency ( Battery Mode )
Current Crest Ratio
Harmonic Distortion
OUTPUT
Charging Current (max.)
TRANSFER
TIME
INDICATOR
AUDIBLE
ALARM
ENVIRONMENT
INTERFACE
BAT <--> LINE
INV <--> BYPASS
ECO --> INV
LCD
Battery Mode
Low Battery
Fault
Overload
Operating Environment
Relative Humidity
Noise Level
RS232/USB
External Slot
EPO
5 hours to 90%
1.2A
0ms
0ms
<10ms
Load level/Battery Level/Battery Mode/AC Mode/Bypass
Mode / Fault
Sounding every 4 seconds
Sounding every second
Continuously Sounding
Sounding twice every second
0-40° C
0-95% (NON-CONDENSING)
<50dB @ 1 Meter
Software supports Windows Family, Linux, Sun Solaris, IBM
Aix, Compaq True64, SGI IRIX, FreeBSD, HPUX, and MAC
SNMP/AS400/Relay Card
Emergency Power Off
Desktop - Specifications
Processor
Chipset
Memory
Networking
QTY
: Intel® Core™ i5-4590 Processor (Quad Core, 6MB, 3.30GHz w/HD4600Graphics)
: Intel Intel® Integrated Graphics
: 4 GB Non-ECC dual-channel 1600MHz DDR3 SDRAM, supports up to 16GB
: Integrated Realtek RTL8151GD Ethernet LAN 10/100/1000; supports
optional PCIe 10/100/1000 network card, optional wireless 802.11n card
60 No’s
I/O Ports
: 2 external USB 3.0 ports (rear) and 6 external USB 2.0 ports (2 front, 4 rear);
1 Serial port (optional); 1 RJ-45; 1 VGA; 1 DisplayPort 1.2;
1 Mic-in & 1 Headphone out (front); 1 Mic-in/Line-in & 1 Line-out(rear)
Audio
: Builtin internal speaker
Removable Media : Supports optional optical disc drives and media card reader options
Hard Drives
: 1TB sata
Chassis
: Screw less Small Form Factor
Power Supply
: Standard 280W or above
Monitors
: 19.5” LED Monitor
Keyboards & Mice : Standard USB Keyboard and Mouse
Security Lock
: Trusted Platform Module6 (TPM), Data Protection Security Tools,
Data Protection/ Encryption, Chassis lock slot support, Chassis Intrusion
Switch, Setup/BIOS Password, I/O Interface Security, Ant-Theft
Technology, KACE Security
Warranty
: 3 Years onsite NBD
Server - Specifications
Processors
: Intel Xeon processor E5-2600 v3 product family
Chipset
: Intel C610 series chipset
Processor sockets
: 2
Internal interconnect : Two QPI links at 9.6 GT/s
Cache
: 2.5MB per core
Memory
: 16GB DDR4 2133MHz
I/O slots
: Support for up to total of 6 full-height PCIe 3.0 slots
RAID controller
: RAID 5
Network controller
: 2 x 1GbE LOMs
Hard drives
: 600GB X 5 SAS
Optical Drive
: DVDRW
I/O adapter options
: Broadcom® 5720-based rack network daughter card
Monitors
: 19.5” LED Monitor
Keyboards & Mice
: Standard USB Keyboard and Mouse
Power supply
: 750W
Operating systems
: Microsoft Windows Server 2008/2012
Form factor
: Tower
Warranty
: 3 Years onsite NBD
QTY
1 No
STEREO HEADPHONES
- SPECIFICATIONS

Supra-aural Headphones

Noise Cancelling

Swivel, folding design for ultra-portability

Unit for clear and rich sound

Wired Connectivity

Over the Head

On the Ear Headphone
LAN INSTALLATION- SPECIFICATIONS

16 U Floor Mount Rack with two-power manager, two cable manager and wheels.

24 port Gigabit Ethernet switch
: 03

24 Port CAT6 Patch Panel
: 03

CAT6 I/O Box with SMB
: 65

CAT6 Bundle (305 m)

CAT6 2m Patch Cables
: 70

CAT6 1m Patch Cables
: 70

Service Charges for Connecting ,laying, fixing, Including all accessories for 65 points

Wireless Access point 300mbps double : 02
Display Type

Number of pixels
Projection Lens
QTY
(65Points)
QTY
: 3 LCD
Size of effective display area

(60 No’s)
: 05
LCD PROJECTORS - SPECIFICATIONS

QTY
: 0.63”(16 mm) x 3 BrightEra LCD Panel,
Aspect Ratio 4:3
: 2,359,296 (1024x768 x 3) pixels
:Zoom – Ratio : Approx. x 1.6
Throw Ratio : 1.40:1 to 2.27:1


Light Source
Screen Size

Light output, Display Resolution

Input Outputs:
: Ultra high pressure mercury lamp/210 w type
: 30” to 300” (0.76 m to 7.62 m)
: Lamp mode high 3800 lm
:Video input connector: Pin jack
S video input connector: Mini DIN 4-pin
HDMI input connector: HDMI 19-pin, HDCP
support
(2 No’s)

Remote commander

Wireless On/Off Switch LAN- RJ-45, 10BASE-T/100BASE-TX

connector*4: Mini D-sub 15-pin,USB
AIR CONDITIONER 01
SPECIFICATIONS
QTY
2 Ton, 3 star and above rated Split Air Conditioner
05 No’s
Capacity 22,170 BTU/h, Power source :230v 50Hz, 7200 watts, Input power watts 1800-2160,

current amps 8.5-10, Moisture Removal,1tr/hr 2.2, Air flow – High m3/hr - 1120
Compressor type : Hyper Tropical, cooling capacity 6500 watts and above, microprocessor controlled
codeless remote.
02
05 No’s
Voltage stabilizer

5 KVA Voltage stabilizer wall mount type with no time delay high-low voltage
Thermal overload protection input voltage 130-300v,output voltage 200-240v,High
voltage cutoff 240v,frequency 50Hz.
LABFURNITURE
S.No
1
2
DESCRIPTION
LINEAR WORKSTATION SIZE 900W X 600D X1200HT
Specification:
System - 53mm Slide on system. Partition 53mm thick tile Slide base system.
Extrusion made up of CRCA sheet and powder coated, top and side caps of
aluminum extrusion powder coated, with ABS and caps, with 9mm thk. Tile based
panels of Marker/ Fabric/ Laminate/ Pin up. TOP made with 25mm thk.Pre-laminated
particle board, 18mm thk Pre-laminated particle board for gable ends, exposed edges
lipped with PVC tape. With Glass Partition 8mm thk. with single Draw, CPU
Trolley, Metal Key board
Supply and delivery of Revolving Chair of Advantage Medium back of size
600Wx545Dx980Hmm, Seat Height 455-555mmm, seat and back made of 12mm
thick hot pressed plywood with waterfall curvature, cushioned with high-density
cold cured self-skinned pre-molded foam of 65 density , upholstery with fabric done
is by using high-pressure pneumatic spray glue and penumatic presses, the backrest
has height adjustment as well as built in contoured lumber support, permanent
contact mechanism with gaslift, puch back mechanism with 2 point locking facility
QTY
60No’s
60No’s
with 25mm stroke gas operator stem, tilt tenstion adjustment, fixed PU arms and five
prog Nylon base with glass filled Nylon castors adhering to as per BIFMA
Standards/ISO Certified.
3
4
4-Seater Rectangular Meeting Table size: 1500W X 900D X 750HT
Specification:
System :-25mm thick prelaminated particle board ,all the exposed edges finished
with 2mm edge lipping
Under Structure:-Supported on powder coated MS Square Leg 50 x 50 and Beams
as per BIFMA Standards/ISO Certified
Supply of Value back Medium back chair with Indian synchro, gaslift and height
adjustable arms.. Seat uphostery approved fabric and back imported mesh fabric
Chair Height 900mm, width 600mm , depath 575, Seat Height 450 to 550mm as per
BIFMA Standards/ISO Certified.,
01 No
04No’s
MODULAR CABIN & BLINDS
Description
Units
1. Modular Cabin: (a)Double skin partition of 1.5 thk. extrusion made up of PLB sheet and
powder coated, top and side caps of aluminum extrusion powder coated, with ABS end
caps, with 9mm thk.
Total
510 Sft
2. Sizes: 6F X 12F
=72 Feet
10F X 12F=120 Feet
7FX 10F
=70 Feet
7FX 10F
=70 Feet
7FX 10F
=70 Feet
9FX 12F
=108 Feet
5 X 5 Vertical Blinds
11 widows
Download