LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata Instrument Description Data Acquisition Data Processing WHAT IS MASS SPECTROMETRY? Mass spectrometry is an analytical technique that involves the study in the gas phase of ionized molecules with the aim of one or more of the following: • Structural characterization • Gas phase reactivity study • Qualitative and quantitative analysis of components in a mixture. • Molecular weight determination LC/MS and GC/MS Mass Spectrometers GC/MS Micromass GCT LC/MS Agilent QTOF 6540 m/z Inlet Direct Probe Flow Injection GC, LC Ion Source EI, CI APCI, ESI Analyzer Q, QQQ EB, Ion Trap TOF, QTOF FT, Orbitrap Detector EM, PM Data System Applications of Mass Spectrometry •Pharmaceutical analysis •Biomolecule characterization Proteins and peptides Oligonucleotides •Environmental analysis Pesticides on foods Soil and groundwater contamination •Forensic analysis/clinical TOF EQUATION TIME OF FLIGHT SCAN QTOF 6540 CAPABILITIES MS and MS/MS Mass Accuracy of better than 3ppm Resolution (FWHM) 45,000 for mass 1000 Rapid switching between positive and negative ion modes LC SYSTEM 4 reservoir bottles A1, A2, B1, B2 Binary Pump can handle up to 8000 psi UV detector LC Column housing Autosampler ELECTROSPRAY IONIZATION Desolvation + Coulomb Explosions AGILENT ELECTROSPRAY ION SOURCE (POSITIVE MODE) ELECTROSPRAY SPECTRUM OF MYOGLOBIN RELATIVE APPLICABILITY OF LC/MS TECHNIQUES ADVANTAGES OF ELECTROSPRAY • Soft ionization • LC/MS interface with best sensitivity • Extends mass range for multiply charged analytes • Works with a wide range of moderate to high polarity compounds • Low maintenance ELECTROSPRAY SOLUTION CHEMISTRY Mobile phase pH has a major effect for analyte that are ions in solution - Basic pH (>7.0; 9 preferred) for negative ions - Acidic pH (<7.0; 5 preferred) for positive ions - Manipulation of pH can enhance performance for analytes that are not normally ionized in solution - QTOF 6540 ION PATH ELEMENTS MASS SPECTROMETER TYPE: MASS ACCURACY • • • • • Quadrupole 200-300 ppm Linear Time of Flight 200 ppm Reflectron Time of Flight 25-50 ppm OR-Time of Flight 1-3 ppm Fourier Transform MS 0.1-1 ppm MASS ACCURACY-DEVIATION IN PPM EXACT MASS CALCULATION AND DEVIATION HOW MUCH MASS ACCURACY IS NEEDED? Elemental composition implication TOF RESOLUTION Resolution is the ability to distinguish between two mass peaks that are extremely close together Resolution = M / Peak Width (FWHM: full width at half maximum) LC/MS OF SEMIX (10 UG/ML) 10 PPM LC/ESI pos of : L-Selenocysteine (Peak#1); MethSeCy (#2); SeMethionine(#3); Etionine(#4) Agilent XDB C18, 1.8 um, 4.6mm ID, 150 mm L L-Selenocysteine MW 168 SelenoMethinine MW196 MethylSelenoCysteine MW 182 MW 163 QUALITATIVE DATA PROCESSING MASS HUNTER QUAL SOFTWARE Open File Use default layout: Chromatogram, Mass Specta Process and print data Display mass spectrum Average few scans Background substraction Peak integration POSITIVE ION MODE LC/ESI OF SEMIX SELECTED IONS FROM SEMIX ESI MASS SPECTRA OF SEMIX LC/ESI OF SURFACTINE MIXTURES 14 DALTON DIFFERENCE BETWEEN COMPOUNDS POSITIVE ION MODE APCI OF CAROTENOIDS m/z Positive ion mode LC/APCI is the method of choice for analyzing and quantifying Carotenoids