ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION I II III Fives Fives Pillard - GAS DETECTORS OPACIMETERS ANEMOMETERS Driving Progress 1 VIEW OF OUR SCOPE OF SUPPLY IN TUNNEL Burner Opacimeters/ Dust monitors Anemometers Ignitor's tube Gas detector Smoke detector Fives Pillard 2 TUNNEL DEPARTMENT II - OPACIMETERS OPASTOP 3000 T OPASTOP 3000 S OPASTOP 3000 ST Fives Fives Pillard Driving Progress 3 VISUAL & VERSIONS OPACIMETER GP 3000T Fives Pillard GP 3000S GP3000ST 4 OPERATING PRINCIPLE GP 3000T GP 3000S GP3000ST Location In situ In local control room In situ Technology Measuring by environmental optical backscatter Measuring by optical backscatter in a measuring vessel Measuring by reflection Measure of dust Measuring chamber Continuously Measure points 1 sample point 2 sample points 1 sample point Heating system to eliminate fog - Integrated integrated Light Drift compensation against fouling Fives Pillard Modulated light beam by high power LED Not integrated Contamination control and automatic drift compensation against fouling 5 TECHNICAL SPECIFICATIONS OPASTOP GP 3000T GP 3000ST GP 3000S POWER SUPPLY 230V / 115V (+10/-15%) 50HZ / 60HZ 230V / 115V (+10/-15%) 50HZ / 60HZ 230V / 115V (+10/-15%) 50HZ / 60HZ POWER CONSUMPTION 100 VA 50 VA 30 VA without turbine 210 with turbine up to 15 metres 1,1 kva with turbine up 100 meters MEASURING RANGE 0 to 16.10-3 K 0 to15.10-3 E/m 0 to15.10-3 K OPERATING TEMPERATURE -20°c TO 50°C -20°c TO 50°C -20°c TO 50°C STORAGE TEMPERATURE -20°c TO 60°C -20°c TO 60°C -20°c TO 60°C HOUSING Stainless 304 L Stainless steel 316 L Stainless steel 316 L PROTECTION IP 65 IP 65 IP 54 DESIGN Modular design Compact cabinet Compact cabinet ANALOG OUTPUT 4-20mA on750 Ohms 4-20mA on750 Ohms LOGIC OUTPUT 2 threshold relays,1 general fault relay 2 threshold relays/1 alarm relay/1 extraction fan command relay 2 threshold relays,1 general fault relay,2 solenoid control relays WEIGHT 13Kg 10Kg 6Kg 4-20mA on750 Ohms 6 OPASTOP GP 3000ST OPASTOP GP3000ST Measuring by reflection, in situ Modulated light beam by high power LED Automatic drift compensation against fouling Stainless steel 316L Heating system to eliminate fog (50w) GP3000 S OPASTOP GP3000S Measuring by extraction sampling Modulated light beam by high power LED Automatic drift compensation against fouling Possibility of managing two sample points Heating system to eliminate fog (50w) OPASTOP GP3000S & GP3000 ST: presentation GP 3000S GP 3000 ST Suction inlet Aspiration (with protection (avec protection against contre water splash) projection eau) Entrée (Tube aspiration) Suction inlet (with protection against water splash) Coffret de mesure Measuring panel Measuring panel Coffret de mesure Carte électronique principale Main electronics board électronique MainCarte electronics board principale Capteur Sensor (Chambre de mesure) (measuring chamber) Sensor Capteur (measuringde chamber) (Chambre mesure) Ventilateur Air fan Sortie (vers turbine d'aspiration) Discharge Filtre Filter Filtre Filter Refoulement Discharge GP3000 T OPASTOP GP3000T Measuring by reflection, in situ Modulated light beam by high power LED Single sensor integrated in electronic panel Modular design OPASTOP GP3000T: définition of the system Measuring unit (Receiver) A cone of modulated light is emitted from a light source module. A receiver positioned at 90° to the light source unit receives part of the reflected light from the suspended particles. A sweeping air system enables the fibre optic tips to stay clean. Light emitter OPASTOP GP3000T: définition of the system Measuring Panel Measuring unit (Receiver) Sweeping air inlet Main Circuit Board Light generator (Emitter) 100 VA Main Electric Supply Ambiant air inlet Phase (L1) Earth ( ) Neutral (N) 250 VA Panel terminal for air treatment Electric supply Air treatment unit Filter Outlet for treated air Air Pump PROTECTION & CERTIFICATION Protection rating (as per EN60529) : Protection against dust Hermetically sealed against dust IP65 Protection against water spray Water sprayed by a jet on the protection cell, from whatever direction, will have no detrimental effect. 13 VIEW OF FITTED PRODUCTS 14 MAINTENANCE Calibration device Maintenance operations · The general appearance of the wiring in the cabinet, · The cleanliness of electronic circuits (de-dusting with power off) · The condition of the panel door seal, · The condition of the sensor filter · The condition of the fan . Filter replacement