Modèle de conception Fives

advertisement
ANALYSERS & INSTRUMENTS DEPT.
TUNNEL ROAD APPLICATION
I
II
III
Fives
Fives Pillard
-
GAS DETECTORS
OPACIMETERS
ANEMOMETERS
Driving Progress
1
VIEW OF OUR SCOPE OF SUPPLY IN TUNNEL
Burner
Opacimeters/
Dust monitors
Anemometers
Ignitor's
tube
Gas detector
Smoke detector
Fives Pillard
2
TUNNEL DEPARTMENT
II
-
OPACIMETERS
OPASTOP 3000 T
OPASTOP 3000 S
OPASTOP 3000 ST
Fives
Fives Pillard
Driving Progress
3
VISUAL & VERSIONS
OPACIMETER
GP 3000T
Fives Pillard
GP 3000S
GP3000ST
4
OPERATING PRINCIPLE
GP 3000T
GP 3000S
GP3000ST
Location
In situ
In local control room
In situ
Technology
Measuring by
environmental optical
backscatter
Measuring by optical
backscatter in a
measuring vessel
Measuring by reflection
Measure of dust
Measuring chamber
Continuously
Measure points
1 sample point
2 sample points
1 sample point
Heating system to
eliminate fog
-
Integrated
integrated
Light
Drift compensation
against fouling
Fives Pillard
Modulated light beam by high power LED
Not integrated
Contamination control and automatic drift
compensation against fouling
5
TECHNICAL SPECIFICATIONS
OPASTOP
GP 3000T
GP 3000ST
GP 3000S
POWER SUPPLY
230V / 115V (+10/-15%) 50HZ
/ 60HZ
230V / 115V (+10/-15%) 50HZ
/ 60HZ
230V / 115V (+10/-15%) 50HZ /
60HZ
POWER CONSUMPTION
100 VA
50 VA
30 VA without turbine
210 with turbine up to 15 metres
1,1 kva with turbine up 100 meters
MEASURING RANGE
0 to 16.10-3 K
0 to15.10-3 E/m
0 to15.10-3 K
OPERATING
TEMPERATURE
-20°c TO 50°C
-20°c TO 50°C
-20°c TO 50°C
STORAGE
TEMPERATURE
-20°c TO 60°C
-20°c TO 60°C
-20°c TO 60°C
HOUSING
Stainless 304 L
Stainless steel 316 L
Stainless steel 316 L
PROTECTION
IP 65
IP 65
IP 54
DESIGN
Modular design
Compact cabinet
Compact cabinet
ANALOG OUTPUT
4-20mA on750 Ohms
4-20mA on750 Ohms
LOGIC OUTPUT
2 threshold relays,1 general
fault relay
2 threshold relays/1 alarm
relay/1 extraction fan
command relay
2 threshold relays,1 general fault
relay,2 solenoid control relays
WEIGHT
13Kg
10Kg
6Kg
4-20mA on750 Ohms
6
OPASTOP GP 3000ST
OPASTOP GP3000ST
 Measuring by reflection, in situ
 Modulated light beam by high power LED
 Automatic drift compensation against fouling
 Stainless steel 316L
 Heating system to eliminate fog (50w)
GP3000 S
OPASTOP GP3000S
 Measuring by extraction sampling
 Modulated light beam by high power LED
 Automatic drift compensation against fouling
 Possibility of managing two sample points
Heating system to eliminate fog (50w)
OPASTOP GP3000S & GP3000 ST: presentation
GP 3000S
GP 3000 ST
Suction inlet
Aspiration
(with protection
(avec
protection against
contre water splash)
projection eau)
Entrée
(Tube
aspiration)
Suction
inlet
(with protection against water splash)
Coffret
de mesure
Measuring
panel
Measuring
panel
Coffret
de mesure
Carte
électronique
principale
Main
electronics
board
électronique
MainCarte
electronics
board principale
Capteur
Sensor
(Chambre
de mesure)
(measuring
chamber)
Sensor
Capteur
(measuringde
chamber)
(Chambre
mesure)
Ventilateur
Air fan
Sortie
(vers turbine d'aspiration)
Discharge
Filtre
Filter
Filtre
Filter
Refoulement
Discharge
GP3000 T
OPASTOP GP3000T
 Measuring by reflection, in situ
 Modulated light beam by high power LED
 Single sensor integrated in electronic panel
 Modular design
OPASTOP GP3000T: définition of the system
Measuring unit (Receiver)
A cone of modulated light is emitted
from a light source module.
A receiver positioned at 90° to the
light source unit receives part of the
reflected light from the suspended
particles.
A sweeping air system enables the
fibre optic tips to stay clean.
Light emitter
OPASTOP GP3000T: définition of the system
Measuring Panel
Measuring unit
(Receiver)
Sweeping air inlet
Main Circuit Board
Light generator
(Emitter)
100 VA
Main
Electric
Supply
Ambiant air inlet
Phase (L1)
Earth ( )
Neutral (N)
250 VA
Panel terminal for
air treatment
Electric supply
Air treatment unit
Filter
Outlet for treated air
Air Pump
PROTECTION & CERTIFICATION
Protection rating (as per EN60529) :
Protection against dust
Hermetically sealed against dust
IP65
Protection against water spray
Water sprayed by a jet on the protection cell,
from whatever direction, will have no detrimental
effect.
13
VIEW OF FITTED PRODUCTS
14
MAINTENANCE
Calibration device
Maintenance
operations
· The general appearance of the wiring in the cabinet,
· The cleanliness of electronic circuits (de-dusting with power off)
· The condition of the panel door seal,
· The condition of the sensor filter
· The condition of the fan
. Filter replacement