ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION I II III Fives Fives Pillard - GAS DETECTORS OPACIMETERS ANEMOMETERS Driving Progress 1 VIEW OF OUR SCOPE OF SUPPLY IN TUNNEL Burner Opacimeters/ Dust monitors Anemometers Ignitor's tube Gas detector Smoke detector Fives Pillard 2 TUNNEL DEPARTMENT I- GAS DETECTOR NOCOSTOP V2 Fives Fives Pillard Driving Progress 3 I- NOCOSTOP VIEW OF THE PRODUCT 4 OPERATING PRINCIPLE NOCOSTOP V2 NOCOSTOP V2 In situ In sampling Electrochemical Cell Electrochemical Cell Continuously Continuously Type Technology In situ Type of measure In sampling Type of Gas measured Material Fives Pillard NO / CO / NO2 NO / CO / NO2 1 cell by gas 1 cell by gas ABS ABS 5 TECHNICAL SPECIFICATIONS OPASTOP NOCOSTOP V2 Mechanical characteristics Mechanical characteristics Housing protection Dimensions / Weight ABS Material (Stainless steel in option) IP65 127 x 150 x 80 mm / 500 g Anti-water splash device Integrated Particle filter Integrated Metrological characteristics Measuring range Resolution CO: 0 –100 to 300 ppm ; NO : 0-10 to 100 ppm ; NO2 : 0-1 to 10 ppm CO and NO : 0,1 ppm ; NO2 : 0,05 ppm Accuracy CO : 2 ppm ; NO : 0,2 ppm ; NO2 : 0,1 ppm Lower detection limit CO : 1 ppm ; NO : 0,5 ppm ; NO2 : 0,2 ppm Response time Expected lifetime Drift Temperature range < 30 s > 3 years < 5% per year - 40°C to +65°C 6 ELECTRICAL CHARACTERISTICS Electrical characteristics Power supply 24 VDC +10/-15% Power consumption 0,7 W without heating / 12 W with heating Interfacing Compatible with RC3 communication console Communication by 4/20 mA connection Fault warning Signal between 1 and 3 mA 7 WEIGHT, SIZE & DIMENSIONS Weight = 500 g 8 Electrical connection Designation of the cable conductors Positive pole 24V Negative pole 24V Positive pole of 4-20mA loop Negative pole of 4-20mA loop Earth Use Detector power supply 24VDC (0,450 A when operating with heater) Current loop outlet (Toxic gas concentration) Earth for electrical protection and CEM 9 ACCESSORIES, OPTIONS, SERVICES Display: LCD screen on front face Extractive measure Adaptor for gas circulation Maintenance LC3 console Housing Stainless steel 304L Calibration kit for maintenance Services for testing, assistance with commissioning, annual, maintenance contract etc…. 10 VIEW OF FITTED PRODUCT Fives Pillard 11 Earth + 24 VDC - 24 VDC + 4-20 mA 4-20 mA ELECTRICAL OUTPUT 12 PRODUCT MAINTENANCE I- Calibration of the equipment I) + II- + Replacement of the filter + + 13 MAIN ADVANTAGES Easy start-up and maintenance In situ version Simple calibration, without dismantling One cabinet : possibility 3 cells thermo-regulated (1 per cabinet) Adjustable scale 0 à 300ppm of CO 0 à 100 ppm of NO 0 à 10 ppm of NO2 Extractive version Protection IP65 Calibration gas Remote control Two possible configurations In-situ or extractive measuring