Introduction – Project and Partners Background – Steve Poole Funding (E.On) – Rupert Butt Design Challenges (DES) – Paul Fisher Project Hardware (Projection) – Steve Poole Outcome – (NRCH) – Dave Guy Facts and Figures (Projection) – Steve Poole Conclusions and Questions Background ◦ Project Scope Replace existing Tungsten light source with LED Retain the existing lighting points Recreate exactly the same lighting feel Compatible with existing DMX control system Seamless dimming to zero Viable ROI Energy Performance Contracting A program of works where the capital cost is recovered through energy savings which are guaranteed by E.ON £ Implementation costs (incl. financing) £ £ Guaranteed savings p.a. £ £ £ Client net benefit £ £ £ Guaranteed savings period Ongoing savings Savings in the early years repay the initial capital investment thereby limiting client risk Nottingham Energy Performance Contract • E.ON secured a contract under the RE:FIT Framework to deliver an EPC for Nottingham City Council. • £1.2M Investment to deliver a 26% energy saving across 8 buildings, including Leisure Centres, Care Homes and a Sports Stadium. • All savings guaranteed for 7 years in order to pay back the original investment. • One of the 8 Buildings is the Royal Concert Hall. Design Challenges (DES) ◦ The issues that needed to be resolved Sourcing suitable product Existing light fittings Consistent and effective dimming Control interface The building Emergency Lighting Commissioning Design Challenges (DES) Existing Fittings (High Level) 300W Par Lamps Design Challenges (DES) The Building Project Hardware – AlphaLED ◦ High Level Lighting (20m+ Height) 60 x Bespoke fittings created Mechanical Interface 2700 CCT – To match tungsten “feel” 3000Lm 28° Beam For punch and penetration. Replaced 300W R95 lamps Project Hardware – AlphaLED ◦ Low Level Lighting 458 Down lighters Across 4 levels. 2700 CCT Match tungsten feel 700lm @ 11.5 TCW. Replaced 75W Lamps AlphaLED Attributes ◦ Initial Colour Consistency 1 x 2 step SDCM specification. Consistent wall washing ◦ Colour Consistency Guaranteed No colour shift over life (5 years, 50,000 hrs) ◦ Low Lumen Depreciation L95 50,000 hrs capability Control Gear ◦ DMX Capable – Dim to Zero Light level EldoLED Powerdrive. • Outcome – Theatre Prospective • LED/energy saving houselights and dimming, the bottom 10% • Maintenance and consumable savings (700 bulb changes a year previously) • Audience reaction to the change Facts and Figures Nottingham Royal Concert Hall - Energy Usage Power (W) Qty Total W Total kW 300W Par 56 300 60 18000 18 75W R95 75 458 34350 34.35 Existing Fittings / Lamps Removed Total 52.35 New AlphaLED Product Installed Bespoke Atrium 28 Deg Beam 3000lm CRI80+ 2700K 46.1 60 2766 2.766 11.5 458 5267 5.267 Atrium with astral bezel 700lm CRI80+ 2700K 8.033 KW Saving 85% saving 44.317 Facts and Figures ◦ The comparison is made assuming the lighting is used in the same way as the existing lighting. In Use Energy Consumption kW Hrs / Day No Days Total Kwh Existing 52.35 14 345 252850.5 New Lighting 8.033 14 345 38799.39 Kwh Saving 214051.11 Use control for further energy savings ◦ Tungsten to LED – saves 85% energy Further energy Savings are possible: ◦ LED with DMX allows for various dimming profiles ◦ Set 100% for Theatre Customer use ◦ Set 65% for cleaning ◦ Set 50% at other times ◦ These are examples only Possible to double the saving In Use Energy Consumption kW Hrs / Day No Days Total Kwh Existing 52.35 14 345 252850.5 New Lighting 100% Level 8.033 4 345 11085.54 New Lighting 65% Level 8.033 5 345 9007.00 New Lighting 50% Level 8.033 5 345 6928.46 Total 14 ◦ Don’t forget to consider use and control 27021.00 Kwh Saving 225829.50 Additional Saving with dimming profile 187030.11 Original Saving 214051.11 Total saving 401081.22 Conclusions ◦ ◦ ◦ ◦ ◦ Substantial Energy Savings are possible Light Quality can be matched Day to day maintenance eliminated Further substantial savings with controls Hardware guaranteed 5 years 50,000hrs Any questions ? Thank You AlphaLED Stand D11