SCATS 6.9.1 Release Review

advertisement
SCATS 6.9.1 Release Review
SMUG, March 2013
Sydney
SCATS 6.9.1 Release Review
This presentation describes the new features
introduced in
SCATS 6.9.1 Commercial Release.
SMUG 2013
2
SCATS 6.9.1 Release Summary
SCATS 6.9.1 Release Scope
• 22 new features
• 19 enhancements
• 24 major issues resolved
In operation at TMC since
January 2012 – V6.9.1.1
Commercial release prepared
in November 2012 –
V6.9.1.11
SMUG 2013
3
SCATS 6.9.1: What’s new
The major changes in this version are:
• Support for Windows® 7 and Windows® Server 2008 R2.
• Support for virtual environments and network dongles to allow
for automatic failover or disaster recovery plans.
• An increase in the number of MSS, RSF and XSF flags from 16 to
32.
• The ability to lock and trim all flags, except MSS flags.
SMUG 2013
4
SCATS 6.9.1: What’s new – cont’d
The major changes in this version are:
• Better support and monitoring of secret walks.
• Improved controller fault management.
• New variation routines for resetting the state and implementing
a logical AND between tests.
• Ability to import the SCATS host licence name and licence
details from the licence file into the two configuration programs
SMUG 2013
5
SCATS 6.9.1: New Features - 1
Time Gain Changes
• The rule introduced in v6.6.3.2 that time gain could only be accepted
from phases that were allowed to gap has been removed!
• A sanity test is now applied to time gain at the end of each phase that
fixes TG build-up observed in Master-Isolated mode and skipping of
the stretch phase.
• Time can now be gained from skipped phases when a dwell is applied.
SMUG 2013
6
SCATS 6.9.1: New Features - 2
Walk monitoring – includes secret walks
• An RPS request is now sent to all controllers every second to get the
demanded walks and the active walks.
• Site diagnostic monitor (IDM) files now show when a walk ended
rather than when a walk termination request was sent.
• The capture of the intersection status when an SC, LC or IH alarm is
generated will also show secret walks (eg More… in Access).
SMUG 2013
7
SCATS 6.9.1: New Features - 3
ST alarm (NXP) review
• The failure of a controller to answer an NXP/CLP message within 8
seconds now generates Fallback instead of an ST alarm.
• An ST is generated only when no messages at all are received for 8
seconds.
• Generate an ST alarm if NXP reply is 16 seconds late – TS mode
• The processing of the Special Facilities for an intersection (Y-, Z-, Z+,
Z1-6, XSF, RSF) are now done for intersections that are not
communicating as they could be used by Variation Routines.
SMUG 2013
8
SCATS 6.9.1: New Features - 4
Improved controller fault log management
• SCATS can now detect a deadlock when a controller fault log is
being automatically retrieved. The fault is logged and SCATS will
retry after 60 seconds which allows RAM/IMAP changes to be saved.
• The controller log can now be saved to the SCATS log file when a
controller has a WD alarm.
• The AL/ command in SCATS Terminal now resets the flag that allows
an RLE fault (Read Log Entry) to be logged.
SMUG 2013
9
SCATS 6.9.1: New Features - 5
Variation Routines
• New variation routine to AND (VR18), implemented.
- When "test" routines follow each other, there is an implied AND between the
routines.
- When an OR is used (VR19), as in A OR B AND C, you get A or (B AND C).
- If you want (A OR B) AND C you must use VR18 for the AND.
- VR18 also allows (A OR B) AND (C OR D)
• VR83 (Test an SA for congestion) now compares the user supplied
DS against the DS from the SI, not the split plan vote DS.
SMUG 2013
10
SCATS 6.9.1: New Features - 6
Variation Routines
• A variation routine (VR10) has been added to reset the variation
routine state to true
• It is now recommended that you use VR10 instead of VR19 (the
OR routine) if you need to reset the state.
• The Variation Routine Usage dialogue now includes the stop routine
(VR0) and longer descriptions.
SMUG 2013
11
SCATS 6.9.1: New Features - 7
Variation Routines
• All the variation routines are
now shown in the Variation
Routine Monitor dialogue with
an icon and description. The
icon identifies the type of
variation routine or whether it
has been skipped, bypassed or
is unknown. A shortcut menu
provides a legend for the
meaning of the icons.
SMUG 2013
12
SCATS 6.9.1: New Features - 8
SCATS Flags
• All flags except MSS can be locked or trimmed to an ON state or an
OFF state.
• Each flag is managed separately.
• A trim cannot be applied if the flag is locked.
• SF and XSF locks no longer require a split plan lock to be applied
(i.e. no PL=0#! Needed)
• SF and XSF trims clear on a split plan change.
SMUG 2013
13
SCATS 6.9.1: SCATS Flags - 1
Flag Types
• SF
Special Facilities: Y-, Z+, ZNo Change
• XSF Extra Special facilities
Increased from 16 to 32 including Flexilink plans, VC6.1
• MSS Miscellaneous Status
Increased from 16 to 32 including Flexilink plans, VC6.1
• Z
Z1 to Z6
No Change
• RSF Remote Special facilities
Increased from 16 to 32, any controller
SMUG 2013
14
SCATS 6.9.1: SCATS Flags - 2
• Indication of a trim or a lock in Access
No flag locks or trims
At least one flag is
trimmed, no locks
SMUG 2013
At least one flag is
locked, there can
be trims
15
SCATS 6.9.1: SCATS Flags - 3
• The Special Facilities form
- Shows current state of all flags
- Indicates the presence of locks and trims
At least one lock,
there can be trims
At least one trim,
no locks
No locks or
trims
SMUG 2013
16
SCATS 6.9.1: SCATS Flags - 4
• Opening a Flag Selector form
- Click a button for the desired flags
- Can open multiple selection forms
SMUG 2013
17
SCATS 6.9.1: SCATS Flags - 5
• The Flags Selector form
-
Shows the current state of the flags of that type
Shows locks and trims
Apply trims ON or OFF
Apply locks ON or OFF
Remove a lock or trim
Show the Locks and
Trims form
SMUG 2013
18
SCATS 6.9.1: SCATS Flags - 6
• The Flags Selector form
- Applying a lock or trim
Trimmed ON
Locked OFF
• Select the state
› Click the ON or OFF button
• Select the type
› No Lock for trim
› Permanent or timed
for a lock
• Click Apply
- Removing a lock or trim
• Locks and trims are shown
in the top section
• Select the lock or trim
to be removed
› Click the button with the
lock or trim icon
• Click Apply
SMUG 2013
19
SCATS 6.9.1: SCATS Flags - 7
• Displaying details of locks and trims
- Click the “Locks and Trims…” button on the Special Facilities form or the Flags
Selector form to display the Locks and Dwells form.
Shows if flag state
is ON or OFF
SMUG 2013
20
SCATS 6.9.1: New Features - 9
• Network intersection IP addresses are now persistent, * indicates
inactive
SMUG 2013
21
SCATS 6.9.1: New Features - 10
• IP address of GUI client is always displayed in Workstation list
SMUG 2013
22
SCATS 6.9.1: New Features - 11
• Ability
to monitor ISS
stretch phase bias
in Access
• Form is
rearranged!
SMUG 2013
23
SCATS 6.9.1: New Features - 12
• Short-cuts defined for SI/SA/LK configuration forms to show their
monitor forms, and vice versa
SMUG 2013
24
SCATS 6.9.1: New Features - 13
Region request log message
• message format is modified to include unknown site request as
specified below,
"region request at CM from SENDER_IPADDR for Site SITEID
replied with (REGNAME at REG_IPADDR:REG_NETPORT)"
or
"region request at CM from SENDER_IPADDR for Unknown site
SITEID"
SMUG 2013
25
SCATS 6.9.1: New Features - 14
Allow master subsystem to rotate (correcting offset errors)
• Early study results
- Increased number of rotations while
- Reduced CL modifications
- Applies between 2 to 10 subsystems
SMUG 2013
26
SCATS 6.9.1: New Features - 15
Force controller clock update even if site is on fallback
• New Region option RK=RC or IK=RC
• A new Reset Clock button to force a clock update
• Good for customers who do not use Flexilink
SMUG 2013
27
SCATS 6.9.1: More features
• VE alarms can be cleared – validation retry is reattempted.
• The change of a controller's dimmed lamp state is now logged
- The current state is also logged at midnight.
• The Fallback panel in SCATS Access is no longer set by an
intersection on fallback that's a member of a subsystem that's on
fallback.
- Additionally, intersections that are members of a subsystem that is on fallback are no
longer included in the fallback summary display
SMUG 2013
28
SCATS 6.9.1: More features
• Number of dwell stores has been increased from 4 to 30
• Number of simultaneous IDM collections increased from 30 to 64
• Limit for daily average volume (AV) increased from 32767 to 65535
• Copy contents of Location field into the Remarks field
- by double clicking on the remarks field in SCATS Access Route Plan editor
SMUG 2013
29
SCATS 6.9.1: Issues addressed - 1
• Reported lamp faults are now displayed in System Status Summary
SMUG 2013
30
SCATS 6.9.1: Issues addressed - 2
• Copying an intersection’s data with the "Use" button now works
SMUG 2013
31
SCATS 6.9.1: Issues addressed - 3
• Menu shortcuts (Ctrl+C, Ctrl+X, Ctrl+V, etc.) were not enabled as
specified so it was not working all the time
SMUG 2013
32
SCATS 6.9.1: Issues addressed - 4
• Buffer overflow reported by VicRoads when there CM crashed
• Region crash during sending region status message
- last intersection in the defined slots has an LF loop count loses its value and crashes
• Region crash when logging an FTP lock
• Region crash when saving Variation Routine 5 in SCATS Access
before nominating an MSS bit
SMUG 2013
33
SCATS 6.9.1: Issues addressed - 5
• TG calculations (bug fix)
- No time gain is obtained from skipped phases when a dwell is applied
- Master Isolated - TG wrongly builds up from a number of cycles
• SI phase time not being set to zero when being skipped
• Any intersection with > 4 split plans and 7 phase (TCS 2861)
- The details in Access not shown correctly – first 10 – 15 sec
- Reported as incorrect Hurry call operation and showing locks/trims that are not
applicable
SMUG 2013
34
SCATS 6.9.1: Issues addressed - 6
• Variation routine monitor
- The on-entry and on-exit values displayed is wrong for VR98 (Skip next entry on
FALSE) and VR99 (Skip next entry on TRUE)
• VR15 (the count routine) does not clear the SCATS flags if the count
type is changed
• Skip checkbox missing for VR99 (Skip next entry on TRUE)
SMUG 2013
35
SCATS 6.9.1: Issues addressed - 7
• Actual link mode is shown and updated in Time/Distance diagram
• Flexilink data dialogue
- validation check for an invalid pulse time highlights incorrect field
• SCATS Log
- Log includes parked alarms and events if a site (s) is specified in the filter
• Alarm Analyser
- Machine re-start reported as crash on Windows Server 2008 R2
SMUG 2013
36
SCATS 6.9.1: Release available
• SCATS 6.9.1 Release is available and recommended to deploy.
• Release notes must be reviewed prior to installation.
• User Manuals are up to date.
• HASP Device drivers are updated.
• Need a new licence – contact SCATS Help!
SMUG 2013
37
SCATS 6.9.1: Known issues
• SCATS Flags (child dialogues) not updated when monitored site
changed
• Communications status not updated in 'Controller communications'
dialogue
• Invalid input to Local (or Controller) Times would yield a deadlock in
SCATS Access
SMUG 2013
38
SCATS 6.9.1: Known issues
• DO NOT USE – RK=LS!
• 16 plans – do not overload variation routines
• New Access ( > 6.8.3.0) with old region (6.5.0.2 and 6.8.3.0), increase
number of plans in Site Edit destroys the slot data – site configuration
is lost
SMUG 2013
39
SCATS 6.9.2: Next step
• Maintenance Release 6.9.2 is now compiled.
• Objective of SCATS 6.9.2 is to provide a maintenance release
addressing outstanding defects and change requests.
• Scope to resolve all outstanding major defects for greater system
stability and reliability.
• A few enhancements are in consideration.
SMUG 2013
40
Download