SCATS 6.9.2 Release Review SMUG, March 2013 Sydney SCATS 6.9.1 Release Review This presentation describes the new features introduced in SCATS 6.9.2 Commercial Release. SMUG 2013 2 SCATS 6.9.2 Release Summary SCATS 6.9.2 Release Scope • Maintenance release • 16+ new features • 16+ bug fixes In operation at TMC since March 2013 – V6.9.2.5 Commercial release is currently compiled. SMUG 2013 3 SCATS 6.9.2: What’s new Recommended Model 2 – improved. - Re-establish connection to SCMS database Prime RC1 Region 1 Prime CM Backup CM Prime RC2 Region 2 … CM DB Replicated CM DB Prime RC6 Backup RC1 Region 1 Region 2 Region 3 Region 4 Region 5 Region 6 Region 6 Prime Dongles SMUG 2013 SCATS CM SCATS CM Backup Dongles 4 SCATS 6.9.2: What’s new - 2 • System Summary dialogue – details are now shown by default. SMUG 2013 5 SCATS 6.9.2: What’s new - 3 • Intersection Alarms: Reset Intersection – AL/ and COM/ SMUG 2013 6 SCATS 6.9.2: What’s new - 4 • Change Request: SCATS Lamp Operations - RK=LS is now retired SMUG 2013 7 SCATS 6.9.2: What’s new - 5 • New “No skip” option defined for VR22 – Dwell a phase SMUG 2013 8 SCATS 6.9.2: What’s new - 6 SCATS Ramp Metering support: • SI data is provided in ITS interface (SRMS only) - Inclusion of VK and DS values for any type SI - With a validated timestamp • SCATS accepts an external dynamic maximum green request for OnRamp Queue Response - Limits excessive green time when no discharge is possible - Applies volume-based "gating“ between the current and upstream intersection SMUG 2013 9 SCATS 6.9.2: What’s new - 7 • All IP addresses are stored in database • Add a REFRESH button to Controller Equipment dialogue • Add logging of DIDO version and serial numbers after establishing connection • Update the look and feel of the Lamp/Lamp Details dialogue SMUG 2013 10 SCATS 6.9.2: What’s new - 8 New Licensing Model • Standalone dongles (green ones) must be present all the time. This is the current operation and a random check is performed. • Network dongles must be present during start-up for authentication. If backup dongle is provided, either of them enables the authentication. SMUG 2013 11 New Licensing Model – cont’d If network dongles become unavailable after successful authentication, a grace period is applied; • Colour code of services reported in Access, right-top corner, will be grey stating either central manager or region dongle is no longer accessible • A system alarm will be raised • Applications are allowed to run until 1 PM next working day! SMUG 2013 12 New Licensing Model – cont’d Unlimited network licences can be utilised as test-bed • Test-beds must be configured as non-production server • Non-production version of central manager will not have following functionalities; - Route pre-emption, Time Distance Diagram, Incident Management, ITS port, Messages, accept non-production region connections only • Non-production version of Region will not have following functionalities; - ITS port, can only connect to non-production central manager SMUG 2013 13 SCATS 6.9.2: What’s new - 9 To be implemented • Time-Distance display includes TG & FG • Show the source of SCATS Flags when • Enhanced Special Dates – support range and priority • Site communication statics optionally over 1 hour period SMUG 2013 14 SCATS 6.9.2: Issues addressed - 1 • An ITS application that sends more than 1100 bytes, crashes Central Manager • Invalid input to Local (or Controller) Times would yield a deadlock in SCATS Access • Link plan lock and trim is removed, monitor windows does not update immediately • Link/Offset Plan dialogue: Changes are lost without warning SMUG 2013 15 SCATS 6.9.2: Issues addressed - 2 • Monitoring a site that is not communicating produces excessive updates which overrides user’s changes in PL0 • SCATS Flags (child dialogues) not updated when monitored site changed • Change of phases, split plan, and walk plans are now logged by Site ID • ITS interface – region name checking is now case insensitive SMUG 2013 16 SCATS 6.9.2: Issues addressed - 3 • Modem Servers settings is lost if region network port is zero • VR24 should not allow setting Z3 flag – reserved VC >= 4 • Communications status not updated in 'Controller communications' dialogue SMUG 2013 17 SCATS 6.9.2: Issues to be addressed • The choice of HDLC or non-HDLC is overridden by SCATS • SCATS clears split plan even though the user has locked the plan • Special facilities dialogue: Usability issues with locks and trims • Show full names of CE alarms in Access • Terminology is reviewed! SMUG 2013 18 Debate • Intersection - Site • Cycle Time – Cycle Length • Phase Flags – Phase Features • Event/Log Print from Central Manager – proposed to be obsolete SMUG 2013 19 Debate – cont’d • Action List editor – editing short cuts versus introduced ones SMUG 2013 20 Discussion HA infrastructure Review / Recommendations • Why do we virtualise? - Save money, conserve energy, secure data - more incentives to virtualise: flexibility and redundancy - http://www.it-ps.com/assets/files/documents/white_paper_why_virtualisation.pdf • How to deal with complexity? SMUG 2013 21 Discussion – cont’d RMS Recommendations • Virtualised Central Manager? • What sort of database replication is recommended? • Distributed versus centralised regional computers? • Link Plan/Rotation monitoring SMUG 2013 22