TamilNadu Circle Network Training Purpose Procedure to check the health of WAN equipment and WAN Links. How to Check the Health of WAN Links In CDR Project we use Network Node Manager (NNM) to check The health and status of Links and Routers 3 How to open NNM Open the Internet explorer, type the URL http://10.196.208.181:7510/topology/home. Cont.. Enter Login User ID and password and click submit. The Login User ID and password for Tamilnadu Circle is as follows, Circle Username Password Tamilnadu Circle TN_User pass123 Monitoring Alarms After Logging into the NNM, below screen appears. Cont.. Click on the Launch View Tab. Cont.. By double clicking on the launch view Tab corresponding SSA will be displayed as below. Cont.. By double clicking on the SSA will be displayed as below 9 MEDIATION & PROVISIONING LINKS Cont.. In Alarm Browser go to View Set Filter. Here we can filter the alarms of Tamil Nadu Circle based on Date/Time, Node, Severity etc. To remove filter Go to View Clear filter. What to do when Node is indicated as Down Ping the router to check the current status of links. If it is pinging wait for NNM screen to get refreshed. After refresh (refresh time is 15min) the links /router should turn back to normal. If Router is not pinging Perform the following steps at Exchange end. a. Conduct the Loop test for E1 Links from Transmission room b. If Loop test is ok, Do Ping test again. c. If Ping test fails execute “Trace route “ from your PC and note IP Add where it is dropping. d. If IP Add is dropping at 172.26.x.x series Please contact NIB/MPLS and Parallely inform CDR Datacenter. 12 Mediation & Provisioning Link Checkup You found all the links are ok but mediation portal still states CDR are not up to date than It is possible that though E1 links are ok the connectivity between the router and PSTN switch is down. Before we get into checking this part …lets understand how the PSTN switch is connected to Exchange Router. 13 PSTN SWITCHS CONNECTIVITY TO CDR EXCHANGE/LE-ROUTER 14 EXCHANGE ROUTER PORT to PSTN SWITCH connectivity Connect to Second Location E1 link Connect to First Location E1 link Free Connecting All exchanges -PROVISIONING Connecting 5ESS/EWSD/OCB MEDIATION Connecting E10B-PC - MEDIATION Connecting CES/MTE-AXE MEDIATION 15 CDOT EXCHANGE MEDIATION RJ45 CONNECTOR CROSS CABLE CES Fast Ethernet 0/0 CISCO IOP IOP ACTIVE STANDBY CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER CABLE : HCL TO PROVIDE 2811 ROUTER SERIAL PORT Serial 0/1/1 FOR PROVISIONING RS232 25 PIN FEMALE RS232 25 PIN MALE PROVISONING 2Mbps WAN LINK TOWARDS DATACENTER EWSD EXCHANGE X.21 15 PIN MALE X.21 15 PIN FEMALE PROVISIONING LAU For Serial 0/1/1 Provisioning CISCO EWSD SWITCH CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER CABLE : HCL TO PROVIDE 2811 ROUTER LAU Serial 0/0/0 For Mediation X.21 15 PIN MALE X.21 15 PIN FEMALE MEDIATION 2Mbps WAN LINK TOWARDS DATACENTE R 5ESS EXCHANGE PROVISIONING RS232 25 PIN FEMALE RS232 25 PIN MALE UN582B Serial 0/1/1 For Provisioning CISCO 2811 5ESS SWITCH CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER CABLE : HCL TO PROVIDEROUTER UN582B Serial 0/0/0 For Mediation V.35 34 PIN MALE V.35 34 PIN FEMALE MEDIATION 2Mbps WAN LINK TOWARDS DATACENT ER OCB EXCHANGE PROVISIONING RS232 25 PIN FEMALE RS232 25 PIN MALE ACTUJ Serial 0/1/1 CISCO OCB SWITCH CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER 2811 CABLE : HCL TO PROVIDE ROUTER Serial 0/0/0 ACV11 X.25 25 PIN MALE RS 530 25 PIN FEMALE MEDIATION 2Mbps WAN LINK TOWARDS DATACENTER AXE 10 / IP TAX EXCHANGE CISCO AXE-10 / IP TAX CROSS CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER 2811 ROUTER SWITCH Ethernet Port For FA 0/0 Mediation MEDIATION / PROVISIONING 2Mbps WAN LINK TOWARDS DATACENTER E10B EXCHANGE (ECIL SCSI) PROVISIONING RS232 25 PIN FEMALE RS232 25 PIN MALE Serial 0/1/1 CISCO 16 CCM H/W SERIAL PORT 2811 FOR PROVISIONING ROUTER E1OB SWITCH CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER CABLE : HCL TO PROVIDE Fast Ethernet 0/0 OMC MTE ETHERNET CONNECTIVITY MTU INTERFACE CABLE MEDIATION 2Mbps WAN LINK TOWARDS DATACENTER E10B EXCHANGE (ECIL PERTECH/ISI) PROVISIONING RS232 25 PIN FEMALE RS232 25 PIN MALE Serial 0/1/1 CISCO 16 CCM H/W SERIAL PORT 2811 FOR PROVISIONING ROUTER E1OB SWITCH CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER CABLE : HCL TO PROVIDE Fast Ethernet 0/0 OMC MTE ETHERNET CONNECTIVITY MTU INTERFACE CABLE MEDIATION 2Mbps WAN LINK TOWARDS DATACENTER E10B EXCHANGE (MITRA OMC) PROVISIONING RS232 25 PIN FEMALE RS232 25 PIN MALE Serial 0/1/1 CISCO EP54.01 SERIAL PORT 2811 FOR PROVISIONING ROUTER E1OB SWITCH CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER CABLE : HCL TO PROVIDE Fast Ethernet 0/0 OMC MTE ETHERNET CONNECTIVITY MTU INTERFACE CABLE MEDIATION 2Mbps WAN LINK TOWARDS DATACENTER EWSD TCP/IP BASED EXCHANGE PROVISIONING X.21 15 PIN MALE X.21 15 PIN FEMALE LAU Serial 0/1/1 For Provisioning CISCO EWSD SWITCH RJ4 5 2811 CABLE : HCL TO PROVIDE CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER ROUTER SWITCH Fa 0/0 PORT Cat cable with RJ45 connector 24 MEDIATION 2Mbps WAN LINK TOWARDS DATACENTER What to check in case of CDOT switches Communication between exchange router to CES ( Ethernet cable) Communication between CES to IOP 0 & IOP 1. Admn password. Exchange router to active IOP Detailed documentation to perform tests between (CES - IOP for Mediation) & (Exchange router – IOP for Provisioning) available with ITPC. 25 CES CONNECTIVITY TO IOP AND ROUTER 26 Check Availability of CDR Files in CES In Windows Explorer type the URL ftp://<IP Address of CES>/cdr/blg Type the Username & password. Request for username & password can be raised with ITPC . Cont.. It opens a window which displays all the CDR files available within the CES. Check Availability Of CES First Ping to CES IP by giving the command from your desktop which access to CDR network. ‘Ping <IP Address of CES>’ If not pinging, then try to Ping to Exchange Router IP. If not pinging E1 links might be down. recheck in NNM If pinging then check the interface status of fast ethernet 0/0 in NNM. How to Verify Definations Updation status for clients In CDR Project we use Symantec Client Security (SCS) to Protect network from Virus 30 Cont.. Go to Program files – select Symantec system centre console - SSCC 31 Cont.. Extract Symantec system center and Unlock the southdcav server group 32 Cont.. Give the credentials for the southdcav 33 Cont.. Select your server group and check the definition tab to check client def update status if definition tab not present please select antivirus view in menu bar 34 Check Infected PC. Daily mailer from data centre list the PC ‘s infected with virus Following report displays the details of infected PC’s of Erode SSA in Tamilnadu Circle.