VENIPUNCTURE
**keep in mind, as per policy, each provider only gets x2 attempts.
Supplies:
• Clean gloves
• Tourniquet
• Alcohol swab (x2)
• 2x2 gauze (x2)
• adhesive bandage/tape
• Vacutainer
• Sterile double needle (x2)
• Blood specimen tubes
• Identification labels
• Biohazard bag
1. Check orders, gather appropriate supplies.
A. We could also check if if the pt is on any anticoagulant therapy or has
low platelets (↑ risk for bleeding and hematoma formation).
2. Introduce self to patient and identify pt using 2 identifiers. Verify patient
preparation (dietary restrictions, fasting, date and time of last dose of meds
if relevant to testing).
3. Explain procedure, ask pt if any questions. Ask pt about previous
venipuncture experiences. Do they have an arm preference?
4. Raise bed to comfortable working height and have pt in semi-Fowlers or
supine (if pt has fainted in the past).
5. ASSESS --> contraindicated sites: IV infusion, hematoma, mastectomy,
hemodialysis shunt, impaired skin integrity.
A. Also would be mindful of noting any valves, bifurcations, size/length
of selected vein
6. Place pillow or rolled towel under selected arm.
7. Apply tourniquet 2-4" above selected area **NO LONGER THAN 1 MIN!**
A. If you can't palpate distal pulse, tourniquet too tight (will impede
arterial flow)
B. Have pt form a fist
8. Apply clean gloves - a healthy vein should feel firm and rebound on
palpation (a thrombosed vein is rigid and rolls easily)
Blood collection:
• Attach Vacutainer to double-ended needed, have proper blood tube resting
inside.
• Clean selected site with alcohol swab in a circular motion from the inside to
outside. Allow to air dry.
• Take cap off needle, gently pull skin taught 1" below site to stabilize vein.
Inform the pt that "poke" will happen, lasting only a few seconds.
• Hold needle at a <30° angle from skin with bevel up and slowly insert needle
into vein.
• Once blood flow established, inform pt to open their hand and remove
tourniquet.
• Fill to required volume (usually indicated by dark line on tube)
• Keep collecting tubes, remembering to invert each tube numerous times after
collection.
• Once done, apply gauze over puncture site and quickly/carefully withdraw
needle from vein and apply pressure over site for 2-3 minutes or until
bleeding stops (can be up to 5 mins for those on blood thinners).
• Apply bandage or tape over gauze. Assess for hematoma.
• Discard of supplies.
• LABEL specimen tubes (horizontally, writing top-bottom) and put in biohazard
bag and ensure pt is feeling ok before leaving the room. HAND HYGIENE!
• Call SPD to pick up blood.
• DOCUMENT!
◦ How the pt tolerated the procedure.
◦ How many attempts, location of unsuccessful attempts.
◦ Did hemostasis happen in the expected amount of time?
L
prevents
1991 1dies
mum
amanda
immisgu.ly
fiiiiiI
TUBE INVERSIONS
Coagulation = 3-4x
Serum = 5x
Heparin = 8-10x
EDTA = 8-10x
Fluoride/oxalate = 8-10x
ACCIDENTAL ARTERIAL
PUNCTURE:
• Will appear bright red (arterial
blood is ++ oxygenated)
• Visual pulsation of blood in the
line (as arterial blood is under
higher pressure)
What to do:
• Remove needle!!!
• Apply firm pressure with gauze
over the puncture site for at
least 5 mins
• Continue to monitor site for
persistent bleeding, hematoma,
swelling, any coolness, pallor,
and/or pt reports of tingling/
numbness in the distal arm
GENERAL ASEPTIC FIELD
BY CLEANING WORK
SURFACE/using tray!!!!
surgicalasepsis
standardasepsis
critical asepsis
field
micro asepsis field
CVADS
iiEai c
msn.meamainam
mammin
Eti
iiiam
infection
lower
risu
**a CVC is an indwelling device that is inserted into a large central vein
(tip of catheter terminates in the SVC at the cavoatrial junction). There
are SHORT TERM (internal jugular, subclavian and femoral -typically
non-tunnelled) and LONG TERM (PICCs inserted in basilic, cephalic, or
brachial, tunnelled and ports in IJ and subclavian) devices. Short-term
CVCs dwell time = ~2wks, Long-term CVCs = ~1yr+
CVC use is indicated when:
• Poor peripheral venous access (due to trauma, skin integrity)
• Need for long-term IV therapy (whether it be medications, fluids, or
TPN)
• Administration of vesicant solutions/medications
• Hemodynamic monitoring
• Rapid fluid/blood product administration
Can be discontinued when:
• No longer requires long-term IV therapy, no frequent blood sampling,
hemodynamic monitoring no longer needed, no longer in use, risks
outweigh benefit
pkg
🔑 KEY PARTS: ports, needless connectors
🔑 KEY SITES: insertion site
3 MOST COMMON COMPLICATIONS:
1. INFECTION (Central Line Associated Bloodstream Infection)
A. s/s: fever, hypotension, tachycardia, malaise, erythema + warmth around insertion
site, purulent drainage, tenderness/pain
B. prevention: preventing microorganisms from entering bloodstream --> keeping site
clean and dry (dressing changes), maintaining aseptic technique, replacing tubing
as per policy, maintaining a closed system, removing line when no longer
indicated.
2. EMBOLISM (most commonly air embolism)
A. s/s: sudden dyspnea, coughing/gasping for air, chest pain, cyanosis, confusion/
agitation, hypotension, altered LOC
B. prevention: maintaining a closed system (ensuring connections are tight, device
intact, always clamping the lumen when appropriate, priming all tubing and
flushes
3. OCCLUSION
A. s/s: absent blood return, sluggish/delayed blood return, ↑ resistance when
flushing, complete inability to flush, frequent downstream occlusion alarms
B. prevention: flushing as per policy using 10 mL syringe NS push-pause method
that creates turbulence to keep line free from fibrin, preventing drug
incompatibilities
pictured: short-term internal jugular
central line, open. Orange attachment
ASSESSMENT:
is a SecurAcath
Performed qshift and before/after each use
• Location (verify on chart for placement confirmation on XR)
• Dressing (type? intact?) **changed q7days or PRN
orPRN
changedgacenis
caps
• Site (redness, drainage, swelling, pain, sutures, subcut
emphysema,
securement
device?)
• External length (compare to previous shift)
pictured: long-term PICC
• How many ports? any damage? clamps and needless connectors intact? curos caps?
• What fluids are infusing?
pictured: PICC StatLock
CVAD DRESSING CHANGE
Supplies:
• Dressing tray
• CVAD sterile dressing + label
• Sterile gloves
• Blue gloves
• x 3 CHG swabs
• x2 masks
PROCEDURE:
1. Review orders - check last documented external length.
2. Gather supplies
3. Hand hygiene
4. Introduce self to pt and identify pt using 2 identifiers.
5. Explain procedure to pt - position pt - prep working area **WIPE DOWN
SURFACE**
6. Hand hygiene.
7. Apply mask (pt and nurse).
8. Apply blue gloves.
9. Assess insertion site, look at external length.
10. FOR PICC - MEASURE MID-ARM CIRCUMFERENCE (10 cm above ACF)
11. Remove existing dressing + securement device if PICC
12. Cleanse site and catheter with CHG swabs for 30 seconds total. Allow to air
dry. Remove blue gloves.
13. Hand hygiene.
14. Prepare sterile dressing tray and lay sterile drape.
15. Add supplies to dressing tray and apply sterile gloves.
16. Apply dressing with blue strip in middle. Press down to adhere with warmth.
If a PICC, we put the new securement device on first (this is what we need to
be sterile for the PICC, arrows need to face ↑, keep straight, don't kink.)
17. Label dressing.
18. Remove gloves + hand hygiene.
19. Document.
CVAD CAP CHANGE/FLUSH
Supplies:
• Dressing tray
• Blue gloves
• x3 needless connectors
• x2 masks
• alcohol wipes
• x6 sterile NS flushes
PROCEDURE:
1. Review orders.
2. Gather supplies.
3. Hand hygiene.
4. Introduce self to pt and identify pt using 2 identifiers.
5. Explain procedure to pt - position pt - prep working area **WIPE DOWN SURFACE**
6. Hand hygiene.
7. Apply mask (pt and nurse).
8. Prepare sterile dressing tray and lay sterile drape.
9. Add supplies to dressing tray and apply blue gloves.
10. Prime new connectors using pre-filled 10 mL NS syringes.
11. Remove and discard old needless connector.
12. Scrub the hub with an alcohol swab for 15 seconds, dry for 5 seconds.
13. Connect newly primed needless connector and NS flush.
14. Flush 2 mL of NS to establish patency, then pull back for blood return (if blood enters syringe, need to discard and start
flushes over).
15. Flush remaining volume according to policy.
16. Repeat will all lumens.
17. Remove gloves + hand hygiene.
18. Document.
TRACH SUCTIONING
Supplies:
• Suction kit
• Sterile gloves
• Blue gloves
• Sterile saline
oxygen tubing
• Temporary inner cannula (non-fenestrated)
• Ambu bag
**^^delivers 100% oxygen^^**
PROCEDURE:
1. Check order.
2. Is the pt TRACH DEPENDENT? What type of tracheostomy tube do they have?
3. Gather supplies.
4. Hand hygiene.
5. Introduce self to pt and identify pt using 2 identifiers.
6. Explain procedure to pt - position pt (in High Fowlers)- prep working area **WIPE
DOWN SURFACE**
7. Apply pulse oximeter.
8. Complete respiratory assessment.
9. Hyper-oxygenate pt.
10. Set up suction, check to ensure working, set to regular @ 100-150 mmHg.
11. Hand hygiene.
12. Open suction kit and temporary inner cannula.
13. Pour sterile water into box using standard ANTT.
14. Attach catheter to suction (still with blue gloves) ensuring to keep tubing sterile
and place on pt chest.
15. Remove oxygen from pt.
16. Stabilize faceplate with L-hand and remove inner cannula ("lefty loosey")
17. Put in temporary inner cannula, ("righty tighty")
18. Apply oxygen.
19. Put on sterile gloves.
20. Pick up catheter with non-sterile hand (L) and shake off bag.
21. Grab catheter end with sterile (R) hand, suction sterile water
22. Remove oxygen.
23. Advance catheter until resistance at the carina (this induces cough reflex)
24. Pull up 1-2cm and intermittently suction for max 15 seconds on way out.
25. Apply oxygen, allow pt to recover for 1 minute between passes (monitor spO2, any
resp distress, increased HR)
26. Clear catheter with saline.
27. Repeat for up to maximum of 3 passes.
28. Replace inner cannula.
29. Respiratory assessment.
30. Document.
SUCTION INDICATIONS:
**purely on a PRN basis**
• Audible secretions
• ↑ WOB, ↓ SPO2
• ++ visible secretions
around stoma
A tracheostomy is a surgically created opening (tracheal stoma) between the
2nd + 4th tracheal rings as a means of establishing an artificial airway for:
1. Emergency airway protection/obstruction
2. Prolonged mechanical ventilation
3. Chronic conditions that impair breathing or secretion clearance OR
4. Certain surgeries around the face + neck
They can be temporary or permanent, cuffed, uncuffed, fenestrated or nonfenestrated
Supplies:
NG INSERTION
• Blue gloves
• Cup + straw
• pH strips + medicine cup
• Water-soluble lubricant
• NG device
• Kleenex (for pt since eyes may water on insertion)
• NG securement device
• Syringe with tip
• Attachment device "connector"
• Safety pin or tape
Indications:
• Gastric
decompression
(removal of gastric
contents, i.e., gas +
fluid)
**Blue pigtail serves
as a small vent tube
- prevents reflux of
gastric contents
INSERTION PROCEDURE:
1. Check order (could also check to see if theres an order for bloodwork to monitor
electrolytes while pt on NG)
2. Gather supplies.
3. Hand hygiene.
4. Introduce self to pt and identify pt with 2 patient identifiers.
5. Explain procedure to pt - position pt (High Fowler's) - prep working area **WIPE
DOWN SURFACE**
6. Ensure that suction is set up at bedside and working prior to starting.
7. Assess nare patency. Sniff test. Assess pt for contraindications of NG insertion (due
to increased risk of possible perforation or intracranial placement, e.g., facial trauma/
recent facial surgery, basilar #s, esophageal obstruction/stricture) Other difficulties
could be: Has the pt ever broken their nose? Deviated septum?
8. Once nare is picked, give couple sprays of Drisdain, wait a couple minutes and a
couple shots of Lidocaine up his nose (helps to numb area and ease insertion).
9. Place drape on pt.
10. Complete NG measurement (NOTE: this is not a sterile procedure so you can touch
tubing with blue gloves).
A. NEX + 10 cm so that tip is in the middle-to-lower 1/3 of the stomach.
11. Inform pt to take a deep breath - have pt look straight forward. Insert NG up nose
straight and then aim down towards the earlobe.
12. When at back of throat, have pt lean their head forward, chin-to-chest, (opens up
passage into stomach by widening esophagus and closes off passage into lungs).
13. Second staff member or pt could be drinking and swallowing at this point during
insertion which assists the tube into the stomach until you reach the necessary
measurement.
14. Monitor pt for respiratory distress during insertion (sudden excessive coughing,
dyspnea, drop in O2 sat)
15. Hold onto NG while getting nasal device and apply.
16. Remove pigtail. Attach syringe with tip and aspirate gastric contents. Apply pigtail
and place above stomach (on shoulder)
A. Visual assessment: will look like what pt is throwing up. Gastric can be cloudy
and green, tan/off-white
B. pH assessment: gastric = <5.5, intestinal = 6.0, respiratory = 7.0+ **GOLD
STANDARD NSG ASSESSMENT FOR PLACEMENT**
17. Once placement confirmed, hook up to suction with attachment device between
suction tubing and NG.
18. Tape tubing to shoulder, give enough slack so that pt can turn head.
19. Turn on suction to LOW INT SUCTION 80 mmHg (prevents erosion or tearing to
stomach lining)
20. Discard supplies.
21. Document.
REMOVAL:
1. Intermittently clamp and unclamp NG tube for a trial period of several hours while
monitoring the pt for any nausea, vomiting or distension.
2. Put pigtail back in.
3. Turn off suction.
4. Use 10 mL of NS or SW to flush NG (ensures tube is free of debris + away from
gastric lining)
5. Take off nasal piece.
6. Inform pt to take deep breath and hold it.
7. Remove NG tube in swift, quick motion (pt will feel like nose is running).
8. Discard of NG and NG canister (in biohazard waste).
9. Document.
• Gastric lavage
(washing out the
stomach to remove
ingested toxins)
• Med adm
• Enteral feeding
Nursing Assessments/Mngmt:
• Aspirate contents each time
(+ test pH) fluids/meds are
given or once/shift for
continuous feeds
• External tube length
• General site assessment
(surrounding skin, drainage)
• Adm flushes as per orders/
policy to maintain patency
after feeds and meds
(NEVER use a blocked tube
- stop all infusions or feeds
• q8hrs clean area around
nostril, assess nare
patency, moisturize nares
with water soluble lubricant
• 360 rotation q24hr
• Change fixator device q3
days and PRN
NG LOSSES:
We would be monitoring for...
• Hypovolemia (moreso
with large gastric fluid
removal with continuous
suction)
• **Electrolyte losses**
major electrolyte lost is K+
(hypokalemia -> weakness,
arrhythmias),
hypochloremia
• Metabolic alkalosis (++
removal of HCl from
stomach = ++ hydrogen
ion loss = ↑ bicarb =
alkalosis
IV PUSH
PROCEDURE:
1. Check order.
2. Is the pt on intermittent or continuous fluids? What fluids?
3. Check IV reconstitution page (does it need to be reconstituted?)
4. Calculate dosage math, what do we have on hand?
A. What syringe size will we need?
5. Go to IV adult Quick Guide or formulary. Do we need to dilute?
6. Calculate push rate.
7. Gather supplies + **WIPE DOWN WORK SURFACE**
8. 1ST CHECK when taking out pts drawer.
9. Prepare med, remember to maintain micro critical field, keeping keep parts clean.
10. 2ND CHECK after drawing up med.
11. Label syringe.
12. 3RD CHECK when putting pt's drawer back.
13. Administer med.
14. First 2mL of flush do at the same push rate, then do push-pause for the rest.
A. SPEED SHOCK -->
15. Document.
10 Rights of Med Admin:
1. Right TIME
2. Right PERSON
3. Right ROUTE
4. Right DRUG
5. Right DOSE
6. Right DOCUMENTATION
7. Right REASON
8. Right to REFUSE
9. Right EDUCATION
10. Right EVALUATION
RECONSTITUTE ☐
MATH (to draw up mL) ☐
DILUTE ☐
PUSH RATE ☐