ADEO 1X4
T8
Architectural Recessed Luminaire
Project Name
Date
Catalog Number
Type
CONSTRUCTION Formed 20 gauge cold rolled steel housing. Highly reflective die-formed white painted reflector.
Wiring access available on top of housing.
OPTICS Captive and hinged center satine curved, co-extruded acrylic lens with ribbed side channels evenly illuminates
the side reflector giving the appearance of a fully lensed luminaire.
ELECTRICAL Instant start 120/277V electronic ballast with less than 10% THD. Standard single circuit. Each ballast
provided with disconnects to meet luminaire disconnect code requirement.
MOUNTING Designed to install into acoustical grid and inaccessible ceilings. Specify G1, G9 or GS for acoustical grid
ceiling. Specify FL or S for inaccessible ceilings. Grid retention clips integral to housing. Consult factory for detailed
installation
Adeoinstructions.
1x4 (AD14)
Adeo 1x4 (AD14)
FINISH Powder-coat white painted finish on exposed trim.
LABELS UL and cUL Listed, approved for dry/damp location unless otherwise noted.
Side View
4-3/8”
YEAR
WARRANTY
4-3/8”
2”
12"
48"
LFL
YEAR
WARRANTY
Convertible
LED
LAMP OPTIONS
LFL
Satine Lens (A)
Baffle (B)
1 T8
Linear Slot (L)
LED
LAMP OPTIONS
LFL
2 T8
1 T8
Round Perf (R)
HOUSING
AD14A- Adeo 1X4
Recessed with
Satine Lens
AD14R- Adeo 1X4
Recessed with
Round Perf
AD14L- Adeo 1X4
Recessed with
Linear Slot
AD14B- Adeo 1X4
Recessed with
internal Baffle
AD14BF- Adeo
1X4 Recessed
Satine Lens with
internal Baffle
LAMPS
2 T8
Sample
Catalog #: AD14A-2T8-G1-120-1C-W
YEAR
WARRANTY
__-
___-
MOUNTING
VOLTAGE
___-
LFL
Convertible
L U M I N A I R E S P E C I F I C AT I O N
AD14__-
4-3/8”
12"
Convertible
LED
Convertible
Baffle with
Satine Lens (BF)
LED
1T8- (1) 32W T8
2T8- (2) 32W T8
__CIRCUITING
120- 120 V
277- 277 V
347- 347 V1
2
UNV- UNV
YEAR
WARRANTY
Convertible
LED
LED
Convertible
Acoustical Grid Ceiling
G1- 1” Ceiling Grid
G9- 9/16” Ceiling Grid
GS- Screw Slot Ceiling Grid
Inaccessible Ceiling
FL- Standard Flange
(Separate Flange Kit)
S- Surface Mount
(See surface mount specification
sheet for dimensions)
WLED
LED
___
Convertible
OPTIONS
LFL
W- Matte
White
(120/277)
LFL
LFL
Convertible
FINISH
LFL
1C- Single Circuit, Normal
2C- Dual Circuit, Normal3
1D- Single Circuit Dimming7
2D- Dual Circuit Dimming3,7
1E- Single Circuit with
Emergency Circuit7
1B- Single Circuit with a
Battery Pack7
2B- Dual Circuit with a
Battery Pack3,7
QS- Quick Ship4
TW- Through-Wired5
SW- Step Switching7
DSM- Daylight Sensor Master Sensor Included6,7
DSS- Daylight Sensor Satellite Sensor Not Included6,7
GLR- Internal Fast-Blow Fuse
AR- Air Return
CP- Chicago Plenum
FW6- 6’, 18-gauge, Flex Whip
FW12-12’, 18-gauge, Flex Whip
AM- Antimicrobial Paint
1Consult factory for 347 volt ballast. 2Not available for use with a battery pack. 3Dual circuit available for 2 (side-by-side) lamp configurations. 4Quick Ship includes universal voltage, G1, G9, or GS
mounting only, white finish, Chicago Plenum, single (1C) and dual circuit (2C). 5Individual fixtures are through-wired for continuous pattern. Fixtures cannot be joined. 6See back page for ordering information. Requires 0-10 volt dimming. 7Some Adeo configurations will not accommodate all options. Consult factory.
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO
80239 Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
®
© 2016 Pinnacle Architectural Lighting® May 2016
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
4
PHOTOMETRICS
ADEO 1x4 (T8)
742
1242
556
932
371
621
185
311
Test #: 203618
Part #: AD14A-1T8
Total Luminaire Efficiency: 77.0%
Test #: 203629
Part #: AD14A-2T8
Total Luminaire Efficiency: 64.0%
M O U N T I N G D E TA I L
G1 (1”Ceiling Grid) Mounting Options
1” Ceiling Grid with
Standard Tile
1” Ceiling Grid with
Tegular Tile
G9 (9/16”Ceiling Grid) Mounting Options
9/16” Ceiling Grid with
Standard Tile
INTEGRAL DAYLIGHT SENSOR
APPLICATION: Daylight sensor is a turn key solution for lighting control. Integral
sensor is wired to the 0-10 volt dimming ballast at the factory. No additional wiring is
required by the contractor.
DAYLIGHT SENSOR: Daylight sensor dims lights based on electric light and presence
of daylight. Sensor can control up to 20 dimming ballasts. Sensor is factory calibrated
to 45 footcandles (fc), adjustable by 1/3 to 3 times the default setting by rotating the
aperture.
ORDERING INFORMATION: Specify “DSM” or “DSS” in the Options section of
the part number when ordering Integral Daylight Sensor. Daylight Sensor Master (DSM)
includes the fixture with sensor and dimming ballast. Controls DSS units. Daylight
Sensor Satellite (DSS) includes the fixture with a sensor compatible dimming ballast
only. Must be used in conjunction with a DSM unit. (0-10v) dimming must be utilized.
(Sample Catalog #: AD14A-1T8-G1-120-1C-W-DSM)
9/16” Ceiling Grid
with Tegular Tile
GS (Screw Slot Grid) Mounting Options
Screw Slot Ceiling Grid
9/16” Ceiling Grid with
Tegular Tile (fixture flush
with tile)
AIR RETURN
APPLICATION: Air Return is an alternative method
for allowing air to access the plenum. Optional Air
Return slots are located on side panels. Slots are
evenly spaced for most efficient air flow into plenum with minimal distraction
to fixture appearance.
TECHNICAL: Air Return component is integral to the fixture housing. Made
of 20 gauge cold rolled steel painted. Slot size is .50” x .06” and spaced .12”
apart from each other.
ORDERING INFORMATION: Specify Air Return in the options section of
the part number. (Sample Catalog #: AD14A-1T8-G1-120-1C-W-AR)
LAMP AND BALLAST MAINTENANCE
(2) #8-32
Screws
OPENING THE LENS: Locate notch on the
fixture endcap. Pull down on the notched
side to release the lens. Lens swings open.
Lamps
REMOVING BALLAST SCREWS:
Remove (2) screws holding the ballast tray. Be sure to hold tray while
removing the screws.
Notched endcap
ACCESSING THE LAMPS:
Lamps are accessible once
lens is open. Lens remains
captive to fixture housing
during lamp maintenance.
®
Captive Lens
REMOVING BALLAST
TRAY: Gently pull on
socket and ballast
tray will release from
housing. Ballast is fully
accessible.
Ballast Tray
Ballast
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO
80239 Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2016 Pinnacle Architectural Lighting® May 2016
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.