ADEO 2X4 T5, T5HO Architectural Recessed Luminaire Project Name Date Catalog Number Type CONSTRUCTION Formed 20 gauge cold rolled steel housing. Highly reflective die-formed white painted reflector. Wiring access available on top of housing. OPTICS Captive and hinged center satine curved, co-extruded acrylic lens with ribbed side channels evenly illuminates the side reflector giving the appearance of a fully lensed luminaire. ELECTRICAL T5, T5HO: Program start 120/277 volt integral electronic ballast with less than 10% THD. Standard single circuit. Each ballast provided with disconnects to meet luminaire disconnect code requirement. MOUNTING Designed to install into acoustical grid and inaccessible ceilings. Specify G1, G9 or GS for acoustical grid ceiling. Specify FL or S for inaccessible ceilings. Grid retention clips integral to housing. Consult factory for detailed installation instructions. Adeo 2x4 (AD24) Adeo 2x4 (AD24) FINISH Powder-coat white painted finish on exposed trim. LABELS UL and cUL Listed, approved for dry/damp location unless otherwise noted. Side View YEAR Side Vie WARRANTY 3” 24" LFL YEAR WARRANTY Convertible LED LAMP OPTIONS LFL Convertible LED 1 T5 / T5HO Satine Lens (A) Baffle (B) Baffle with Satine Lens (BF) Linear Slot (L) 3” 48" LED24" Convertible LFL LAMP OPTIONS LED Convertible LFL 2 T5 / T5HO 3 T5 / T5HO 1 T5 / T5HO 2 T5 / T5HO Round Perf (R) Sample Catalog #: AD24A-2T5HO-G1-120-1C-W LFL AD24__- _____- __- ___- __- Convertible HOUSING LAMPS MOUNTING VOLTAGE CIRCUITING FINISH 1T52T53T51T5HO2T5HO3T5HO- (1) 28W T5 (2) 28W T5 (3) 28W T5 (1) 54W T5HO (2) 54W T5HO (3) 54W T5HO 3 T5 / T5HO YEAR WARRANTY L U M I N A I R E S P E C I F I C AT I O N AD24A- Adeo 2X4 Recessed with Satine Lens AD24R- Adeo 2X4 Recessed with Round Perf AD24L- Adeo2X4 Recessed with Linear Slot AD24B- Adeo 2X4 Recessed with internal Baffle AD24BF- Adeo 2X4 Recessed Satine Lens with internal Baffle 3” YEAR WARRANTY LFL Convertible LED LED Convertible Acoustical Grid Ceiling G1- 1” Ceiling Grid G9- 9/16” Ceiling Grid GS- Screw Slot Ceiling Grid Inaccessible Ceiling FL- Standard Flange (Separate Flange Kit) S- Surface Mount 120- 120 V 277- 277 V 347- 347 V1 2 UNV- UNV (120/277) (See surface mount specification sheet for dimensions) LFL 1C- Single Circuit, Normal 2C- Dual Circuit, Normal3 1D- Single Circuit Dimming8 2D- Dual Circuit Dimming3,8 1E- Single Circuit with Emergency Circuit4,8 1B- Single Circuit with a Battery Pack4,8 2B- Dual Circuit with a Battery Pack3,4,8 W- LED LED ____ Convertible LFL OPTIONS W- Matte White QS- Quick Ship5 TW- Through-Wired6 SW- Step Switching8 DSM- Daylight Sensor Master Sensor Included7,8 DSS- Daylight Sensor Satellite Sensor Not Included7,8 GLR- Internal Fast-Blow Fuse AR- Air Return CP- Chicago Plenum FW6- 6’, 18-gauge, Flex Whip FW12-12’, 18-gauge, Flex Whip AM- Antimicrobial Paint 1Consult factory for 347 volt ballast. 2Not available for use with a battery pack. 3Dual circuit available for 2 (side-by-side) and 3 (inboard/outboard) lamp configurations. 4Emergency circuit or battery pack to be on center lamp with 3 lamp configurations. 5Quick Ship includes universal voltage, G1, G9, or GS mounting only, white finish, Chicago Plenum, single (1C) and dual circuit (2C). 6Individual fixtures are through-wired for continuous pattern. Fixtures cannot be joined. 7See back page for ordering information. Requires 0-10 volt dimming. 8Some Adeo configurations will not accommodate all options. Consult factory. ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2015 Pinnacle Architectural Lighting® December 2015 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. PHOTOMETRICS ADEO 2x4 (T5, T5HO) 1379 1617 1518 1036 1034 1213 1138 777 689 808 759 518 345 404 379 259 Test #: 203551 Part #: AD24A-2T5 Total Luminaire Efficiency: 91.8% Test #: 203567 Part #: AD24B-2T5 Total Luminaire Efficiency: 92.4% Test #: 203679 Part #: AD24BF-2T5 Total Luminaire Efficiency: 87.7% Test #: 203583 Part #: AD24R-2T5 and AD24L-2T5 Total Luminaire Efficiency: 71.0% M O U N T I N G D E TA I L G1 (1”Ceiling Grid) Mounting Options 1” Ceiling Grid with Standard Tile 1” Ceiling Grid with Tegular Tile G9 (9/16”Ceiling Grid) Mounting Options 9/16” Ceiling Grid with Standard Tile INTEGRAL DAYLIGHT SENSOR APPLICATION: Daylight sensor is a turn key solution for lighting control. Integral sensor is wired to the 0-10 volt dimming ballast at the factory. No additional wiring is required by the contractor. DAYLIGHT SENSOR: Daylight sensor dims lights based on electric light and presence of daylight. Sensor can control up to 20 dimming ballasts. Sensor is factory calibrated to 45 footcandles (fc), adjustable by 1/3 to 3 times the default setting by rotating the aperture. ORDERING INFORMATION: Specify “DSM” or “DSS” in the Options section of the part number when ordering Integral Daylight Sensor. Daylight Sensor Master (DSM) includes the fixture with sensor and dimming ballast. Controls DSS units. Daylight Sensor Satellite (DSS) includes the fixture with a sensor compatible dimming ballast only. Must be used in conjunction with a DSM unit. (0-10v) dimming must be utilized. (Sample Catalog #: AD24A-1T5-G1-120-1C-W-DSM) 9/16” Ceiling Grid with Tegular Tile GS (Screw Slot Grid) Mounting Options Screw Slot Ceiling Grid 9/16” Ceiling Grid with Tegular Tile (fixture flush with tile) AIR RETURN APPLICATION: Air Return is an alternative method for allowing air to access the plenum. Optional Air Return slots are located on side panels. Slots are evenly spaced for most efficient air flow into plenum with minimal distraction to fixture appearance. TECHNICAL: Air Return component is integral to the fixture housing. Made of 20 gauge cold rolled steel painted. Slot size is .50” x .06” and spaced .12” apart from each other. ORDERING INFORMATION: Specify Air Return in the options section of the part number. (Sample Catalog #: AD24A-1T5-G1-120-1C-W-AR) LAMP AND BALLAST MAINTENANCE (2) #8-32 Screws OPENING THE LENS: Locate notch on the fixture endcap. Pull down on the notched side to release the lens. Lens swings open. Lamps REMOVING BALLAST SCREWS: Remove (2) screws holding the ballast tray. Be sure to hold tray while removing the screws. Notched endcap ACCESSING THE LAMPS: Lamps are accessible once lens is open. Lens remains captive to fixture housing during lamp maintenance. ® Captive Lens REMOVING BALLAST TRAY: Gently pull on socket and ballast tray will release from housing. Ballast is fully accessible. Ballast Tray Ballast Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2015 Pinnacle Architectural Lighting® December 2015 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.