ADEO 2X2
T8 and Biax
Architectural Recessed Luminaire
Project Name
Date
Catalog Number
Type
CONSTRUCTION Formed 20 gauge cold rolled steel housing. Highly reflective die-formed white painted reflector.
Wiring access available on top of housing.
OPTICS Captive and hinged center satine curved, co-extruded acrylic lens with ribbed side channels evenly illuminates
the side reflector giving the appearance of a fully lensed luminaire.
ELECTRICAL Standard 55W Biax: Program start 120/277 volt integral electronic ballast with less than 15% THD.
Standard 40W and 25W Biax: Instant start 120/277 volt electronic ballast with less than 10% THD. T8: Instant start
120/277V electronic ballast with less than 10% THD. Standard single circuit. Each ballast provided with disconnects
to meet luminaire disconnect code requirement.
AdeoMOUNTING
2x2 (AD22)Designed to install into acoustical grid and inaccessible ceilings. Specify G1, G9 or GS for acoustical
grid ceiling. Specify FL or S for inaccessible ceilings. Seismic clips integral Adeo
to housing.
Consult factory for detailed
2x2 (AD22)
installation instructions.
FINISH Powder-coat white painted finish on exposed trim.
LABELS UL and cUL Listed, approved for dry/damp location unless otherwise noted.
YEAR
WARRANTY
4-3/8”
24"
LAMP OPTIONS
LFL
4-3/8”
LFL
YEAR
WARRANTY
Side View
Convertible
LED
2”
24"
24"
LED
Convertible
LFL
LAMP OPTIONS
1, 2 Biax
LED
1, 2, 3 T8
1, 2 Biax Convertible 1, 2, 3 Convertible
T8
LED
Satine Lens (A)
Baffle (B)
Baffle with
Satine Lens (BF)
Linear Slot (L)
LFL
Round Perf (R)
YEAR
WARRANTY
L U M I N A I R E S P E C I F I C AT I O N
Sample Catalog #: AD22A-2T8-G1-120-1C-W
AD22__-
____-
__-
___-
__-
Convertible
HOUSING
LAMPS
MOUNTING
VOLTAGE
CIRCUITING
FINISH
AD22A- Adeo 2X2
Recessed with
Satine Lens
AD22R- Adeo 2X2
Recessed with
Round Perf
AD22L- Adeo 2X2
Recessed with
Linear Slot
AD22B- Adeo 2X2
Recessed with
internal Baffle
AD22BF- Adeo
2X2 Recessed
Satine Lens with
internal Baffle
1BX252BX251BX402BX401BX551T82T83T8-
(1) 25W Biax
(2) 25W Biax
(1) 40W Biax
(2) 40W Biax
(1) 55W Biax
(1) 17W T8
(2) 17W T8
(3) 17W T8
120- 120 V
277- 277 V
347- 347 V1
2
UNV- UNV
YEAR
WARRANTY
LFL
Convertible
LED
Convertible
Acoustical Grid Ceiling
G1- 1” Ceiling Grid
G9- 9/16” Ceiling Grid
GS- Screw Slot Ceiling Grid
Inaccessible Ceiling
FL- Standard Flange
(Separate Flange Kit)
S- Surface Mount
(See surface mount specification
sheet for dimensions)
W-
LED
LED
____
Convertible
LFL
OPTIONS
W- Matte
White
(120/277)
LED
LFL
LFL
1C- Single Circuit, Normal
2C- Dual Circuit, Normal3
1D- Single Circuit Dimming8
2D- Dual Circuit Dimming3,8
1E- Single Circuit with
Emergency Circuit4,8
1B- Single Circuit with a
Battery Pack4,8
2B- Dual Circuit with a
Battery Pack3,4,8
QS- Quick Ship5
TW- Through-Wired6
SW- Step Switching (T8)8
DSM- Daylight Sensor Master - Sensor
Included (T8, 1BX55, 2BX40) 7,8
DSS- Daylight Sensor Satellite - Sensor
Not Included (T8, 1BX55, 2BX40)7,8
GLR- Internal Fast-Blow Fuse
AR- Air Return
CP- Chicago Plenum
FW6- 6’, 18-gauge, Flex Whip
FW12-12’, 18-gauge, Flex Whip
AM- Antimicrobial Paint
1Consult factory for 347 volt ballast. 2Not available for use with a battery pack. 3Dual circuit available for 2 (side-by-side) and 3 (inboard/outboard) lamp configurations. 4Emergency circuit or battery
pack to be on center lamp with 3 lamp configurations. 5Quick Ship includes universal voltage, G1, G9, or GS mounting only, white finish, Chicago Plenum, single (1C) and dual circuit (2C). 6Individual
fixtures are through-wired for continuous pattern. Fixtures cannot be joined. 7See back page for ordering information. Requires 0-10 volt dimming. 8Some Adeo configurations will not accommodate all
options. Consult factory.
®
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO
80239 Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2012 Pinnacle Architectural Lighting® April 2012
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
PHOTOMETRICS
ADEO 2x2 (T8, BIAX)
761
856
786
463
571
624
589
347
381
428
393
232
190
214
196
116
Test #: 203621
Part #: AD22A-2T8
Total Luminaire Efficiency: 85.3%
Test #: 203629
Part #: AD22B-2T8
Total Luminaire Efficiency: 83.1%
Test #: 203686
Part #: AD22BF-2T8
Total Luminaire Efficiency: 79.2%
Test #: 203637
Part #: AD22R-2T8 and AD22L-2T8
Total Luminaire Efficiency: 57%
M O U N T I N G D E TA I L
G1 (1”Ceiling Grid) Mounting Options
1” Ceiling Grid with
Standard Tile
1” Ceiling Grid with
Tegular Tile
G9 (9/16”Ceiling Grid) Mounting Options
9/16” Ceiling Grid with
Standard Tile
INTEGRAL DAYLIGHT SENSOR
APPLICATION: Daylight sensor is a turn key solution for lighting control. Integral
sensor is wired to the 0-10 volt dimming ballast at the factory. No additional wiring is
required by the contractor.
DAYLIGHT SENSOR: Daylight sensor dims lights based on electric light and presence
of daylight. Sensor can control up to 20 dimming ballasts. Sensor is factory calibrated
to 45 footcandles (fc), adjustable by 1/3 to 3 times the default setting by rotating the
aperture.
ORDERING INFORMATION: Specify “DSM” or “DSS” in the Options section of
the part number when ordering Integral Daylight Sensor. Daylight Sensor Master (DSM)
includes the fixture with sensor and dimming ballast. Controls DSS units. Daylight
Sensor Satellite (DSS) includes the fixture with a sensor compatible dimming ballast
only. Must be used in conjunction with a DSM unit. (0-10v) dimming must be utilized.
(Sample Catalog #: AD22A-1T8-G1-120-1C-W-DSM)
9/16” Ceiling Grid
with Tegular Tile
GS (Screw Slot Grid) Mounting Options
Screw Slot Ceiling Grid
9/16” Ceiling Grid with
Tegular Tile (fixture flush
with tile)
AIR RETURN
APPLICATION: Air Return is an alternative method
for allowing air to access the plenum. Optional Air
Return slots are located on side panels. Slots are
evenly spaced for most efficient air flow into plenum with minimal distraction
to fixture appearance.
TECHNICAL: Air Return component is integral to the fixture housing. Made
of 20 gauge cold rolled steel painted. Slot size is .50” x .06” and spaced .12”
apart from each other.
ORDERING INFORMATION: Specify Air Return in the options section of
the part number. (Sample Catalog #: AD22A-1T8-G1-120-1C-W-AR)
LAMP AND BALLAST MAINTENANCE
(2) #8-32
Screws
OPENING THE LENS: Locate notch on the
fixture endcap. Pull down on the notched
side to release the lens. Lens swings open.
Lamps
REMOVING BALLAST SCREWS:
Remove (2) screws holding the ballast tray. Be sure to hold tray while
removing the screws.
Notched endcap
ACCESSING THE LAMPS:
Lamps are accessible once
lens is open. Lens remains
captive to fixture housing
during lamp maintenance.
®
®
Captive Lens
REMOVING BALLAST
TRAY: Gently pull on
socket and ballast
tray will release from
housing. Ballast is fully
accessible.
Ballast Tray
Ballast
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO
80239 Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2012 Pinnacle Architectural Lighting® April 2012
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.