ADEO 2X2 T8 and Biax Architectural Recessed Luminaire Project Name Date Catalog Number Type CONSTRUCTION Formed 20 gauge cold rolled steel housing. Highly reflective die-formed white painted reflector. Wiring access available on top of housing. OPTICS Captive and hinged center satine curved, co-extruded acrylic lens with ribbed side channels evenly illuminates the side reflector giving the appearance of a fully lensed luminaire. ELECTRICAL Standard 55W Biax: Program start 120/277 volt integral electronic ballast with less than 15% THD. Standard 40W and 25W Biax: Instant start 120/277 volt electronic ballast with less than 10% THD. T8: Instant start 120/277V electronic ballast with less than 10% THD. Standard single circuit. Each ballast provided with disconnects to meet luminaire disconnect code requirement. AdeoMOUNTING 2x2 (AD22)Designed to install into acoustical grid and inaccessible ceilings. Specify G1, G9 or GS for acoustical grid ceiling. Specify FL or S for inaccessible ceilings. Seismic clips integral Adeo to housing. Consult factory for detailed 2x2 (AD22) installation instructions. FINISH Powder-coat white painted finish on exposed trim. LABELS UL and cUL Listed, approved for dry/damp location unless otherwise noted. YEAR WARRANTY 4-3/8” 24" LAMP OPTIONS LFL 4-3/8” LFL YEAR WARRANTY Side View Convertible LED 2” 24" 24" LED Convertible LFL LAMP OPTIONS 1, 2 Biax LED 1, 2, 3 T8 1, 2 Biax Convertible 1, 2, 3 Convertible T8 LED Satine Lens (A) Baffle (B) Baffle with Satine Lens (BF) Linear Slot (L) LFL Round Perf (R) YEAR WARRANTY L U M I N A I R E S P E C I F I C AT I O N Sample Catalog #: AD22A-2T8-G1-120-1C-W AD22__- ____- __- ___- __- Convertible HOUSING LAMPS MOUNTING VOLTAGE CIRCUITING FINISH AD22A- Adeo 2X2 Recessed with Satine Lens AD22R- Adeo 2X2 Recessed with Round Perf AD22L- Adeo 2X2 Recessed with Linear Slot AD22B- Adeo 2X2 Recessed with internal Baffle AD22BF- Adeo 2X2 Recessed Satine Lens with internal Baffle 1BX252BX251BX402BX401BX551T82T83T8- (1) 25W Biax (2) 25W Biax (1) 40W Biax (2) 40W Biax (1) 55W Biax (1) 17W T8 (2) 17W T8 (3) 17W T8 120- 120 V 277- 277 V 347- 347 V1 2 UNV- UNV YEAR WARRANTY LFL Convertible LED Convertible Acoustical Grid Ceiling G1- 1” Ceiling Grid G9- 9/16” Ceiling Grid GS- Screw Slot Ceiling Grid Inaccessible Ceiling FL- Standard Flange (Separate Flange Kit) S- Surface Mount (See surface mount specification sheet for dimensions) W- LED LED ____ Convertible LFL OPTIONS W- Matte White (120/277) LED LFL LFL 1C- Single Circuit, Normal 2C- Dual Circuit, Normal3 1D- Single Circuit Dimming8 2D- Dual Circuit Dimming3,8 1E- Single Circuit with Emergency Circuit4,8 1B- Single Circuit with a Battery Pack4,8 2B- Dual Circuit with a Battery Pack3,4,8 QS- Quick Ship5 TW- Through-Wired6 SW- Step Switching (T8)8 DSM- Daylight Sensor Master - Sensor Included (T8, 1BX55, 2BX40) 7,8 DSS- Daylight Sensor Satellite - Sensor Not Included (T8, 1BX55, 2BX40)7,8 GLR- Internal Fast-Blow Fuse AR- Air Return CP- Chicago Plenum FW6- 6’, 18-gauge, Flex Whip FW12-12’, 18-gauge, Flex Whip AM- Antimicrobial Paint 1Consult factory for 347 volt ballast. 2Not available for use with a battery pack. 3Dual circuit available for 2 (side-by-side) and 3 (inboard/outboard) lamp configurations. 4Emergency circuit or battery pack to be on center lamp with 3 lamp configurations. 5Quick Ship includes universal voltage, G1, G9, or GS mounting only, white finish, Chicago Plenum, single (1C) and dual circuit (2C). 6Individual fixtures are through-wired for continuous pattern. Fixtures cannot be joined. 7See back page for ordering information. Requires 0-10 volt dimming. 8Some Adeo configurations will not accommodate all options. Consult factory. ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2012 Pinnacle Architectural Lighting® April 2012 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. PHOTOMETRICS ADEO 2x2 (T8, BIAX) 761 856 786 463 571 624 589 347 381 428 393 232 190 214 196 116 Test #: 203621 Part #: AD22A-2T8 Total Luminaire Efficiency: 85.3% Test #: 203629 Part #: AD22B-2T8 Total Luminaire Efficiency: 83.1% Test #: 203686 Part #: AD22BF-2T8 Total Luminaire Efficiency: 79.2% Test #: 203637 Part #: AD22R-2T8 and AD22L-2T8 Total Luminaire Efficiency: 57% M O U N T I N G D E TA I L G1 (1”Ceiling Grid) Mounting Options 1” Ceiling Grid with Standard Tile 1” Ceiling Grid with Tegular Tile G9 (9/16”Ceiling Grid) Mounting Options 9/16” Ceiling Grid with Standard Tile INTEGRAL DAYLIGHT SENSOR APPLICATION: Daylight sensor is a turn key solution for lighting control. Integral sensor is wired to the 0-10 volt dimming ballast at the factory. No additional wiring is required by the contractor. DAYLIGHT SENSOR: Daylight sensor dims lights based on electric light and presence of daylight. Sensor can control up to 20 dimming ballasts. Sensor is factory calibrated to 45 footcandles (fc), adjustable by 1/3 to 3 times the default setting by rotating the aperture. ORDERING INFORMATION: Specify “DSM” or “DSS” in the Options section of the part number when ordering Integral Daylight Sensor. Daylight Sensor Master (DSM) includes the fixture with sensor and dimming ballast. Controls DSS units. Daylight Sensor Satellite (DSS) includes the fixture with a sensor compatible dimming ballast only. Must be used in conjunction with a DSM unit. (0-10v) dimming must be utilized. (Sample Catalog #: AD22A-1T8-G1-120-1C-W-DSM) 9/16” Ceiling Grid with Tegular Tile GS (Screw Slot Grid) Mounting Options Screw Slot Ceiling Grid 9/16” Ceiling Grid with Tegular Tile (fixture flush with tile) AIR RETURN APPLICATION: Air Return is an alternative method for allowing air to access the plenum. Optional Air Return slots are located on side panels. Slots are evenly spaced for most efficient air flow into plenum with minimal distraction to fixture appearance. TECHNICAL: Air Return component is integral to the fixture housing. Made of 20 gauge cold rolled steel painted. Slot size is .50” x .06” and spaced .12” apart from each other. ORDERING INFORMATION: Specify Air Return in the options section of the part number. (Sample Catalog #: AD22A-1T8-G1-120-1C-W-AR) LAMP AND BALLAST MAINTENANCE (2) #8-32 Screws OPENING THE LENS: Locate notch on the fixture endcap. Pull down on the notched side to release the lens. Lens swings open. Lamps REMOVING BALLAST SCREWS: Remove (2) screws holding the ballast tray. Be sure to hold tray while removing the screws. Notched endcap ACCESSING THE LAMPS: Lamps are accessible once lens is open. Lens remains captive to fixture housing during lamp maintenance. ® ® Captive Lens REMOVING BALLAST TRAY: Gently pull on socket and ballast tray will release from housing. Ballast is fully accessible. Ballast Tray Ballast Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2012 Pinnacle Architectural Lighting® April 2012 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.