T5 Specification Sheet - Pinnacle Architectural Lighting

advertisement
Adeo 2x4 (AD24)
ADEO
Adeo Shallow 2x4 (AS24)
2-7/8”
24"
1X4 SHALLOW
Side View
T5
Architectural Recessed Luminaire
1-3/4”
Project Name
Side View
Catalog Number
2-7/8”
Date
24"
Type
1-3/4”
CONSTRUCTION Formed 20 gauge cold rolled steel housing. Highly reflective die-formed white painted reflector.
48"
Wiring
access available on top of housing.
48"
OPTICS Captive and hinged center satine curved, co-extruded acrylic lens with ribbed side channels evenly illuminates
the side reflector giving the appearance of a fully lensed luminaire.
LAMP OPTIONS
ELECTRICAL T5: Program start 120/277 volt integral electronic ballast with less than 10% THD. Standard single
circuit. Each ballast provided with disconnects to meet luminaire disconnect code requirement.
1 T5 / T5HO
2MOUNTING
T5 / T5HO
T5 install
/ T5HO into acoustical grid and inaccessible ceilings. Specify G1, G9 or GS for acoustical grid
Designed3 to
ceiling. Specify FL or S for inaccessible ceilings. Grid retention clips integral to housing. Consult factory for detailed
installation instructions.
FINISH Powder-coat white painted finish on exposed trim.
LABELS UL and cUL Listed, approved for dry/damp location unless otherwise noted.
YEAR
Side
View
WARRANTY
1-3/4”
1-3/4”
12"
LFL
Convertible
LED
Satine Lens (A)
Baffle (B)
Baffle with
Satine Lens (BF)
Linear Slot (L)
48"
LED
Convertible
LFL
Round Perf (R)
YEAR
WARRANTY
L U M I N A I R E S P E C I F I C AT I O N
Sample Catalog #: AS24A-2T5-G1-120-1C-W
AS14__-
2T5-
__-
___-
__-
W-
Convertible
HOUSING
LAMPS
MOUNTING
VOLTAGE
CIRCUITING
FINISH
OPTIONS
AS14A- Adeo
Shallow 1X4
Recessed with
Satine Lens
AS14R- Adeo
Shallow 1X4
Recessed with
Round Perf
AS14L- Adeo
Shallow 1X4
Recessed with
Linear Slot
AS14B- Adeo
Shallow 1X4
Recessed with
Internal Baffle
AS14BF- Adeo
Shallow 1X4
Recessed Satine
Lens, Internal Baffle
2T5- (2) 28W T5
YEAR
WARRANTY
LFL
Convertible
LED
120- 120 V
277- 277 V
347- 347 V1
2
UNV- UNV
(120/277)
Convertible
LED Ceiling
Grid
Acoustical
G1- 1” Ceiling Grid
G9- 9/16” Ceiling Grid
GS- Screw Slot Ceiling Grid
Inaccessible Ceiling
FL- Standard Flange
(Separate Flange Kit)
LFL
____
LFL
LED
LED
Convertibl
W- Matte
White
1C- Single Circuit, Normal
2C- Dual Circuit, Normal3
1D- Single Circuit Dimming7
2D- Dual Circuit Dimming3,7
1E- Single Circuit with
Emergency Circuit7
1B- Single Circuit with a
Battery Pack7
QS- Quick Ship4
TW- Through-Wired5
SW- Step Switching (T5)7
DSM- Integral Daylight Sensor Master Sensor Included6,7
DSS- Integral Daylight Sensor Satellite Sensor Not Included6,7
GLR- Internal Fast-Blow Fuse
AR- Air Return
CP- Chicago Plenum
FW6- 6’, 18-gauge, Flex Whip
FW12-12’, 18-gauge, Flex Whip
AM- Antimicrobial Paint
1Consult factory for 347 volt ballast. 2Not available for use with a battery pack. 3Dual circuit available for 2 (side-by-side) lamp configurations. 4Quick Ship includes universal voltage, G1, G9, or GS
mounting only, white finish, Chicago Plenum, single (1C) and dual circuit (2C). 5Individual fixtures are through-wired for continuous pattern. Fixtures cannot be joined. 6See back page for ordering information. Requires 0-10 volt dimming. 7Some Adeo configurations will not accommodate all options. Consult factory.
®
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO
80239 Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2015 Pinnacle Architectural Lighting® December 2015
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
LF
PHOTOMETRICS
ADEO Shallow 1x4
1536
1765
1489
973
1152
1324
1117
730
788
882
744
487
384
441
372
243
Test #: 203587
Part #: AS14A-2T5
Total Luminaire Efficiency: 86.7%
Test #: 203593
Part #: AS14B-2T5
Total Luminaire Efficiency: 82.4%
Test #: 203696
Part #: AS14BF-2T5
Total Luminaire Efficiency: 76.2%
Test #: 203599
Part #: AS14R-2T5 and AS14L-2T5
Total Luminaire Efficiency: 61.9%
M O U N T I N G D E TA I L
G1 (1”Ceiling Grid) Mounting Options
1” Ceiling Grid with
Standard Tile
1” Ceiling Grid with
Tegular Tile
G9 (9/16”Ceiling Grid) Mounting Options
9/16” Ceiling Grid with
Standard Tile
9/16” Ceiling Grid
with Tegular Tile
GS (Screw Slot Grid) Mounting Options
Screw Slot Ceiling Grid
with tile)
AIR RETURN
INTEGRAL DAYLIGHT SENSOR
APPLICATION: Daylight sensor is a turn key solution for lighting control. Integral
sensor is wired to the 0-10 volt dimming ballast at the factory. No additional wiring is
required by the contractor.
DAYLIGHT SENSOR: Daylight sensor dims lights based on electric light and presence
of daylight. Sensor can control up to 20 dimming ballasts. Sensor is factory calibrated
to 45 footcandles (fc), adjustable by 1/3 to 3 times the default setting by rotating the
aperture.
ORDERING INFORMATION: Specify “DSM” or “DSS” in the Options section of
the part number when ordering Integral Daylight Sensor. Daylight Sensor Master (DSM)
includes the fixture with sensor and dimming ballast. Controls DSS units. Daylight
Sensor Satellite (DSS) includes the fixture with a sensor compatible dimming ballast
only. Must be used in conjunction with a DSM unit. (0-10v) dimming must be utilized.
(Sample Catalog #: AS14A-2T5-G1-120-1C-W-DSM)
APPLICATION: Air Return is an alternative method
for allowing air to access the plenum. Optional Air
Return slots are located on side panels. Slots are
evenly spaced for most efficient air flow into plenum with minimal distraction
to fixture appearance.
TECHNICAL: Air Return component is integral to the fixture housing. Made
of 20 gauge cold rolled steel painted. Slot size is .50” x .06” and spaced .12”
apart from each other.
ORDERING INFORMATION: Specify Air Return in the options section of
the part number. (Sample Catalog #: AS14A-2T5-G1-120-1C-W-AR)
LAMP AND BALLAST MAINTENANCE
REMOVING BALLAST SCREWS:
Remove (4) screws holding the ballast tray. Be sure to hold tray while
removing the screws.
OPENING THE LENS: Locate notch on the
fixture endcap. Lens is removed from opposite side of notch. Pull down on side of lens
to release. Lens will slide off of endcap.
Pull lens
from this side
9/16” Ceiling Grid with
Tegular Tile (fixture flush
Notched endcap
(4) #8-32 Screws
ACCESSING THE LAMPS:
Once lens is fully removed,
lamps are accessible.
Lens Removal
®
Lamps
REMOVING BALLAST
TRAY: Gently pull on
socket and ballast tray
will release from housing.
Ballast is located on the
inside of the ballast tray.
Ballast
Ballast Tray
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO
80239 Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2015 Pinnacle Architectural Lighting® December 2015
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
Download