Protection, Control and Monitoring Easergy T200

advertisement
Protection, Control and Monitoring
Easergy T200
Remote monitoring and control unit
Overview
Easergy T200 has been specially designed to meet the needs of customers in managing MV substations, offering
compact and open-ended solutions.








Easergy T200 I
Management of 1 to 16 switches or circuit breakers
Backup power supply for motorisation, transmission equipment and control unit
High-performance fault current detection
Measurements for better control of the network load
Network reconfiguration automation systems
Communication with the control centre
Monitoring, for local or remote operation
Compatible with any type of SCADA system
Main characteristics
Applications
Switch/circuit breaker monitoring and control
Network automation








Fault current detection
Automation functions
Voltage or current measurements
Concentration of Modbus communication devices
Data and measurements archives
Backup power supply
1 to 2 Serial ports
1 Ethernet and USB port
 Changeover switch (ACO) - The changeover switch
automation system allows for the automatic control
and management of power supply sources in the MV
secondary distribution network.
 Bus tie coupling (BTA) - Bus tie automation is an
automation system for switching sources between two
incoming lines and a busbar coupling switch.
 Sectionaliser (SEC) - The sectionaliser automation
system opens the switch after a predefined number of
faults during the voltage dip in the reclosing cycle of the
upstream circuit breaker.
 Self-healing grid solution - The self-healing grid solution
is designed for Underground networks featuring open-loop
architectures. By employing simple peer-to-peer
communication and step-by-step reconfiguration, it isolates
the faulted area, automatically restoring power to unaffected
customers in under 30 seconds. This translates to higher
power availability in critical areas, a lower SAIDI value,
and greater customer satisfaction.
T200I with Localized
Enclosure
Add-on Cards for FPI,
Current and Voltage
monitoring
Features:
 new automation function (genset automation)
 a continuously updated range of protocols includes the main standards IEC 870-5-101, IEC 870-5-104, DNP3, Modbus
and other proprietary protocols, which allows T200 integration into a wide range of existing monitoring and control platforms
 optimum transmission network management via two serial communication ports and an Ethernet port
 wide range of integrated modems, including radio, PSTN, GPRS, GSM and DL
 web interface for monitoring and control.
8
HV/MV
Pre-fabricated
control cables
MV ring
T200
T200
4-channel
VD 23 Voltage detection relay
Remote control center
Flair 200C
T200
4-channel
T200
Source transfer switch
T200
16-channel
Simulation and Test Kit
39
Customer Service Tel: 0124 4222040
Download