Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that AUXILIARY DEVICES representative samples of Type No. 3RH1911 followed by -1 or -2 followed by F, G, H, L, M, N or X, followed by A, B, C or F followed by 0, 1, 2, 3 or 4 followed by 0, 1, 2, 3 or 4, may be followed by suffix letters and/or numbers. Have been investigated by Underwriters Laboratories in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Investigated to Standard(s) UL508 and C22.2 No. 14 Additional Information: See UL On-line Certification Directory at WWW.UL.COM for additional information. Certificate Number Report Reference Issue Date 20111219-E44653 E44653-19960614 2011-DECEMBER-19 Page 2 of 4 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. GENERAL: These devices are 4 pole auxiliary contact blocks for this manufacturer's devices 3R. RATINGS: A600/Q600 (opposite polarity) 240 V/10 A general purpose Additional Ratings for devices with electronics compatible contacts. 4A continuous current 100 mA, 125 V ac, resistive 300 mA, 60 V dc William R. Carney Director, North American Certification Programs Underwriters Laboratories Inc. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://www.ul.com/global/eng/pages/corporate/contactus Certificate Number Report Reference Issue Date 20111219-E44653 E44653-19960614 2011-DECEMBER-19 Page 3 of 4 NOMENCLATURE BREAKDOWN: 3RH1911 I - 1 II I. Basic Type II. Type of Terminals -1 - Screw Terminal -2 - Cage Clamp Terminal F III A IV 2 V 2 VI III. Mounting Area F,N - top mounted, terminal marking and contact arrangement according to DIN EN 50 005 G - top mounted, terminal marking and contact-arrangement according to DIN EN 50 011 H - top mounted, terminal marking and contact arrangement according to DIN EN 50 012 L - top mounted, entry of conductors top M - top mounted, entry of conductors bottom X - top mounted, special terminal marking. IV. Switching Function A - without determination B - making before breaking, one pair of NO and NC contacts C - making before breaking, two pairs of NO and NC contacts F - electronics compatible contacts V. Contact Arrangements for NO 0non NO 11 NO 22 NO 33 NO 44 NO William R. Carney Director, North American Certification Programs Underwriters Laboratories Inc. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://www.ul.com/global/eng/pages/corporate/contactus Certificate Number Report Reference Issue Date 20111219-E44653 E44653-19960614 2011-DECEMBER-19 Page 4 of 4 VI. Contact Arrangements for NC 0non NC 11 NC 22 NC 33 NC 44 NC VII. Manufacturers Identification .. - Manufacturers Identification William R. Carney Director, North American Certification Programs Underwriters Laboratories Inc. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://www.ul.com/global/eng/pages/corporate/contactus