Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that AUXILIARY DEVICES representative samples of Type No. 3RH1921 followed by -1 or -2 followed by C, F, L, M, H, P or X followed by A, B, C, D, E or J followed by 0, 1, 2, 3 or 4 followed by 0, 1, 2, 3 or 4, may be followed by suffix letters and/or numbers. Have been investigated by Underwriters Laboratories in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Investigated to Standard(s) UL508 and C22.2 No. 14 Additional Information: See UL On-line Certification Directory at WWW.UL.COM for additional information. Certificate Number Report Reference Issue Date 20111219-E44653 E44653-19970422 2011-DECEMBER-19 Page 2 of 4 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. GENERAL: These devices are 1 pole or 4 pole auxiliary contact blocks for this manufacturer's series 3R. RATINGS: A600/Q600 (opposite polarity) 240 V/10 A general purpose William R. Carney Director, North American Certification Programs Underwriters Laboratories Inc. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://www.ul.com/global/eng/pages/corporate/contactus Certificate Number Report Reference Issue Date 20111219-E44653 E44653-19970422 2011-DECEMBER-19 Page 3 of 4 NOMENCLATURE BREAKDOWN: 3RH1921 I - 1 II F III A IV 2 V 2 VI I. Basic Type II. Type of Terminals 1 - Screw Terminal 2 - Cage Clamp III. Mounting Area C - top mounted, 1 pole F - top mounted, terminal marking and contact arrangement according to DIN EN 50 005, 4 pole L - top mounted, entry of conductors top, 2 pole M - top mounted, entry of conductors bottom, 2 pole H - top mounted, terminal marking and contact arrangement according to DIN EN 50 012, 4 pole P - top mounted, terminal marking and contact arrangement according to DIN EN 50 005, 4 pole X - Special version IV Switching Function A - without determination B - making before breaking, one pair of NO and NC contacts C - making before breaking, two pairs of NO and NC contacts D - delayed E - electronics compatible contacts J - electronic compatible contacts William R. Carney Director, North American Certification Programs Underwriters Laboratories Inc. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://www.ul.com/global/eng/pages/corporate/contactus Certificate Number Report Reference Issue Date 20111219-E44653 E44653-19970422 2011-DECEMBER-19 V. Contact Arrangements for NO 0 - non NO 1 - 1 NO 2 - 2 NO 3 - 2 NO 4 - 4 NO VI. Contact Arrangements for NC 0 - non NC 1 - 1 NC 2 - 2 NC 3 - 3 NC 4 - 4 NC Page 4 of 4 William R. Carney Director, North American Certification Programs Underwriters Laboratories Inc. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://www.ul.com/global/eng/pages/corporate/contactus