Metalux D ES C R IPTION The Paralux II Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 2" precision cell louver into a 4-3/4" deep para-contoured fixture housing. This combination creates a total low profile parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The low profile luminaire is designed to offer the market-place a parabolic choice when economics and shallow plenum space are factors. The Paralux II series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching 4-3/4" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Full length die formed stiffeners for added strength. Contoured ballast/ wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. Louver F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Die formed of semi-specular aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place by interlocking feature. True-cut mitered corners. Black reveal with mechanical light seal around entire perimeter of louver. Louver protected by polyethylene cover. 4, 6, 9, 12, 16, 25 Cell 4-3/4" [121mm] MOUNTING D A TA 7/8" [22mm] K.O. (2) 2' X 2' PARABOLIC 2 LAMP SEMI-SPECULAR LOUVER Paralux II Recessed Air Supply Troffer 23-3/4" [603mm] 2/4 LAMP 2P2GAX 2U1-5/8 L AM P C O N F I GURA T IONS Access Plate 7/8" [22mm] K.O. (2) 2 LAMP – 4/6/8 CELL 4-3/4" [121mm] 2" [51mm] X=1-5/8" [41mm] 23-3/4" [603mm] 2 LAMP – 25 CELL 4-3/4" [121mm] X 8-7/8" X [225mm] 23-3/4" [603mm] 2 LAMP – 9/12 CELL 3-5/8" [93mm] 6-7/8" [176mm] 24" [608mm] X 8-7/8" X [225mm] 23-3/4" [603mm] 2 LAMP – 36 CELL 4-3/4" [121mm] 1-3/4" [45mm] 2" [51mm] X=1-5/8" [41mm] ENERGY DATA 4-3/4" [121mm] 2" [51mm] X=1-5/8" [41mm] X 8-7/8" X [225mm] 23-3/4" [603mm] 2" [51mm] X=1-5/8" [41mm] X 8-7/8" X [225mm] 23-3/4" [603mm] Luminaire Efficacy Rating LER = FP-57 Catalog Number: 2P2GAX-2U15/8S33I Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.21 2 LAMP – 16 CELL 4-3/4" [121mm] 2" [51mm] X=1-5/8" [41mm] X Input Watts: EB Ballast & STD Lamps 2U1-5/8 (61) 8-7/8" X [225mm] 23-3/4" [603mm] C EILING C OM PA TIB IL I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ (Verify compatibility/ consult factory.) **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements." LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF090416 2015-10-13 15:02:03 2 P 2 GAX-2 U1 -5 / 8 PH OTOM ETR IC S 2P2GAX-2U1-5/8S33I C a n d l e p o w e r Electronic Ballast FB031T8/35K lamps 2750 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency = 72.2% Test Report: 197P105 LER = FP-57 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.21 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1507 1503 1486 1448 1397 1331 1254 1164 1061 942 808 663 497 305 112 13 6 2 0 2P2GAX-2U1-5/8S44I C a n d l e p o w e r Electronic Ballast Across ⊥ 1507 1511 1504 1497 1478 1462 1449 1383 1279 1210 1117 953 712 378 131 11 6 2 0 45° 1507 1505 1493 1466 1435 1392 1338 1282 1213 1099 956 805 624 396 166 34 7 3 0 FB031T8/35K lamps 2750 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency = 65.8% Test Report: 197P107 LER = FP-52 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.61 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 86 77 68 61 54 48 44 39 36 33 30 86 74 64 55 48 42 37 33 30 27 25 86 72 60 51 44 38 33 29 26 23 21 84 78 72 66 60 56 51 48 44 41 39 84 75 67 59 53 48 43 39 35 33 30 84 73 63 55 48 42 37 33 30 27 25 84 71 60 51 43 38 33 29 26 23 21 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 1205 2008 3564 3970 3970 %Lamp 21.9 36.5 64.8 72.2 72.2 Along II 1509 1506 1481 1437 1380 1311 1231 1137 1030 908 767 610 439 245 51 24 12 4 0 Across ⊥ 1509 1491 1436 1357 1293 1275 1309 1373 1396 1336 1160 862 495 173 24 14 7 2 0 45° 1509 1497 1453 1384 1301 1220 1156 1120 1095 1061 968 795 544 273 82 20 10 4 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 86 80 73 67 62 57 53 49 45 42 40 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 %Fixture 30.4 50.6 89.8 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 80 72 64 57 51 46 42 38 35 32 29 77 70 62 55 50 45 40 37 34 31 29 74 67 60 54 48 43 39 36 33 30 28 80 71 61 53 46 41 36 33 29 27 24 80 69 58 50 43 37 33 29 26 23 21 77 68 59 52 45 40 36 32 29 26 24 77 67 57 49 42 37 32 29 26 23 21 10% 30 10 74 66 58 51 45 39 35 32 29 26 24 74 65 56 48 42 36 32 28 25 23 21 0% 0 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 72 63 54 47 40 35 31 27 24 22 20 Ty p i c a l VC P Pe r c e n t a g e s Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 66 61 75 68 80 74 77 72 82 78 Height Across 8.5’ 10.0’ 62 57 72 65 78 72 75 70 80 77 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 78 73 67 62 57 52 48 45 42 39 37 78 71 63 56 50 45 40 37 33 31 28 78 68 59 51 45 39 35 31 28 25 23 78 66 56 47 41 35 31 27 24 22 20 77 71 66 60 56 51 47 44 41 38 36 77 69 62 55 49 44 40 36 33 30 28 77 67 58 50 44 39 34 31 28 25 23 77 65 55 47 40 35 31 27 24 22 20 20% 50% 50 30 10 30% 50 30 10 50 73 66 59 53 47 43 39 35 32 29 27 70 64 57 51 46 41 37 34 31 29 27 67 61 55 50 45 40 36 33 30 28 26 73 65 56 49 43 38 34 30 27 25 23 73 63 54 46 40 35 30 27 24 22 20 70 62 55 48 42 37 33 30 27 25 22 70 61 53 45 39 34 30 27 24 22 20 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 1118 1862 3353 3621 3621 %Lamp 20.3 33.9 61.0 65.8 65.8 %Fixture 30.9 51.4 92.6 100.0 100.0 10% 30 10 67 60 53 47 41 37 33 29 27 24 22 Height Along 8.5’ 10.0’ 73 68 80 75 83 79 82 78 85 82 67 59 51 45 39 34 30 27 24 21 20 0% 0 66 58 50 43 37 33 29 25 23 20 18 Height Across 8.5’ 10.0’ 72 66 80 74 84 79 83 78 87 83 ORDER IN G INFOR M A TION SAMPLE NUMBER: 2P2GAX-2U1-5/8S33I-UNV-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' Width P=Paralux Louver 2=2" Louver Depth Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (7) F=Aluminum Flange Trim (5) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Number of Lamps 2 lamps Wattage (Length) U15/8=31W T8 (24") Louver Color S=Silver W=White Cell Configuration 22=2 Rows of 2, 4 Cell (2' x 2') 23=2 Rows of 3, 6 Cell (2' x 2') 33=3 Rows of 3, 9 Cell (2' x 2') 34=3 Rows of 4, 12 Cell (2' x 2') 44=4 Rows of 4, 16 Cell (2' x 2') 55=5 Rows of 5, 25 Cell (2' x 2') Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard (Silver Only) MI=Specular/Mirrored (Low Iridescent) (Silver Only) P=Painted (White only) Option – Aluminum Flange Trim (5) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps=Lamps Installed (refer to lamp ordering options) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (6) (1) Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% High Ballast Factor >1.15 No. of Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton Options PAF=Painted After Fabrication REP=Riveted Endplates ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) (2) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for (3) all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies (4) (5) for international markets. Not available when specifying emergencies, voltage must be specific. Specify row (6) configuration, type in catalog number when ordering complete fixture. Fixtures equipped with “EL” option may (7) require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. Louver is recessed by 5/16" in Concealed T or Slot Grid T. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. SH IP P ING D A T A Catalog No. 2P2GAX-2U1-5/8S33II Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Wt. 28 lbs. ADF090416 2015-10-13 15:02:03