D ES C R IPTION
The Paralux II Series features recessed aesthetics and the latest in energy
efficient technology. The luminaire incorporates a 2" precision cell louver
into a 4-3/4" deep para-contoured fixture housing. This combination
creates a total low profile parabolic optical assembly for optimum
performance. The series is compatible with all of today’s popular ceiling
systems and is available with a number of options and accessories for
application versatility. The low profile luminaire is designed to offer
the market-place a parabolic choice when economics and shallow
plenum space are factors. The Paralux II series is an excellent choice
for commercial office spaces, schools, hospitals or retail merchandising
areas.
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
C on s t r u c t i o n
E le ctrica l* *
H inging/Latching
4-3/4" deep, para-contoured
housing, die formed code gauge,
prime cold rolled steel. Full length
die formed stiffeners for added
strength. Contoured ballast/
wireway cover, easily removed
without tools. Die formed captive
lampholder bracket fully encloses
lampholder wiring permitting easy
lampholder replacement. Heavy
end plates, securely attached with
interlocking tabs and screws. Four
auxiliary fixture end suspension
points provided. KOs for
continuous row wiring. End plates
have integral Grid-Lock feature for
safety and convenience.
Ballasts are CBM/ETL Class “P” and
are positively secured by mounting
bolts. Pressure lock lampholders.
UL/CUL listed. Suitable for damp
locations.
Positive cam action spring loaded,
self locking, black steel latches.
Safety lock T-hinges allow hinging
and latching either side.
Louver
F in ish
Lighting grade, baked white
enamel finish. Multistage, iron
phosphate pretreatment ensures
maximum bonding and rust
inhibition.
Die formed of semi-specular
aluminum. Finish is anodic oxide
coating. Accurate precision
parabolic cells are held in place
by interlocking feature. True-cut
mitered corners. Black reveal
with mechanical light seal around
entire perimeter of louver. Louver
protected by polyethylene cover.
4, 6, 9, 12, 16, 25
Cell
4-3/4"
[121mm]
MOUNTING D A TA
7/8" [22mm]
K.O. (2)
2' X 2' PARABOLIC
2 LAMP
SEMI-SPECULAR LOUVER
Paralux II
Recessed Air Supply Troffer
23-3/4"
[603mm]
2/4 LAMP
2P2GAX
2U1-5/8
L AM P C O N F I GURA T IONS
Access Plate
7/8" [22mm] K.O. (2)
2 LAMP – 4/6/8 CELL
4-3/4"
[121mm]
2"
[51mm]
X=1-5/8"
[41mm]
23-3/4"
[603mm]
2 LAMP – 25 CELL
4-3/4"
[121mm]
X
8-7/8"
X
[225mm]
23-3/4" [603mm]
2 LAMP – 9/12 CELL
3-5/8" [93mm]
6-7/8" [176mm]
24" [608mm]
X
8-7/8"
X
[225mm]
23-3/4" [603mm]
2 LAMP – 36 CELL
4-3/4"
[121mm]
1-3/4" [45mm]
2"
[51mm]
X=1-5/8"
[41mm]
ENERGY DATA
4-3/4"
[121mm]
2"
[51mm]
X=1-5/8"
[41mm]
X
8-7/8"
X
[225mm]
23-3/4" [603mm]
2"
[51mm]
X=1-5/8"
[41mm]
X
8-7/8"
X
[225mm]
23-3/4" [603mm]
Luminaire Efficacy Rating
LER = FP-57
Catalog Number: 2P2GAX-2U15/8S33I
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $4.21
2 LAMP – 16 CELL
4-3/4"
[121mm]
2"
[51mm]
X=1-5/8"
[41mm]
X
Input Watts:
EB Ballast & STD Lamps
2U1-5/8 (61)
8-7/8"
X
[225mm]
23-3/4" [603mm]
C EILING C OM PA TIB IL I T Y
G
Grid/Lay-in
Standard
G
Concealed T
G
Slot Grid
F
Aluminum Flange Trim
With Supporting
Swing Gates
MZ
Modular Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
Concealed “T” or ”Z“
Metal Pan
G
G
G
F
MZ
MZ
(Verify compatibility/ consult
factory.)
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements."
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF090416
2015-10-13 15:02:03
2 P 2 GAX-2 U1 -5 / 8
PH OTOM ETR IC S
2P2GAX-2U1-5/8S33I C a n d l e p o w e r
Electronic Ballast
FB031T8/35K lamps
2750 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency = 72.2%
Test Report:
197P105
LER = FP-57
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.21
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1507
1503
1486
1448
1397
1331
1254
1164
1061
942
808
663
497
305
112
13
6
2
0
2P2GAX-2U1-5/8S44I C a n d l e p o w e r
Electronic Ballast
Across ⊥
1507
1511
1504
1497
1478
1462
1449
1383
1279
1210
1117
953
712
378
131
11
6
2
0
45°
1507
1505
1493
1466
1435
1392
1338
1282
1213
1099
956
805
624
396
166
34
7
3
0
FB031T8/35K lamps
2750 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency = 65.8%
Test Report:
197P107
LER = FP-52
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.61
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
86
77
68
61
54
48
44
39
36
33
30
86
74
64
55
48
42
37
33
30
27
25
86
72
60
51
44
38
33
29
26
23
21
84
78
72
66
60
56
51
48
44
41
39
84
75
67
59
53
48
43
39
35
33
30
84
73
63
55
48
42
37
33
30
27
25
84
71
60
51
43
38
33
29
26
23
21
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
0-180
Lumens
1205
2008
3564
3970
3970
%Lamp
21.9
36.5
64.8
72.2
72.2
Along II
1509
1506
1481
1437
1380
1311
1231
1137
1030
908
767
610
439
245
51
24
12
4
0
Across ⊥
1509
1491
1436
1357
1293
1275
1309
1373
1396
1336
1160
862
495
173
24
14
7
2
0
45°
1509
1497
1453
1384
1301
1220
1156
1120
1095
1061
968
795
544
273
82
20
10
4
0
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
86
80
73
67
62
57
53
49
45
42
40
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
%Fixture
30.4
50.6
89.8
100.0
100.0
20%
50%
50 30 10
30%
50 30 10
50
80
72
64
57
51
46
42
38
35
32
29
77
70
62
55
50
45
40
37
34
31
29
74
67
60
54
48
43
39
36
33
30
28
80
71
61
53
46
41
36
33
29
27
24
80
69
58
50
43
37
33
29
26
23
21
77
68
59
52
45
40
36
32
29
26
24
77
67
57
49
42
37
32
29
26
23
21
10%
30 10
74
66
58
51
45
39
35
32
29
26
24
74
65
56
48
42
36
32
28
25
23
21
0%
0
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
72
63
54
47
40
35
31
27
24
22
20
Ty p i c a l VC P Pe r c e n t a g e s
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Height Along
8.5’
10.0’
66
61
75
68
80
74
77
72
82
78
Height Across
8.5’
10.0’
62
57
72
65
78
72
75
70
80
77
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
78
73
67
62
57
52
48
45
42
39
37
78
71
63
56
50
45
40
37
33
31
28
78
68
59
51
45
39
35
31
28
25
23
78
66
56
47
41
35
31
27
24
22
20
77
71
66
60
56
51
47
44
41
38
36
77
69
62
55
49
44
40
36
33
30
28
77
67
58
50
44
39
34
31
28
25
23
77
65
55
47
40
35
31
27
24
22
20
20%
50%
50 30 10
30%
50 30 10
50
73
66
59
53
47
43
39
35
32
29
27
70
64
57
51
46
41
37
34
31
29
27
67
61
55
50
45
40
36
33
30
28
26
73
65
56
49
43
38
34
30
27
25
23
73
63
54
46
40
35
30
27
24
22
20
70
62
55
48
42
37
33
30
27
25
22
70
61
53
45
39
34
30
27
24
22
20
Zonal Lumen Summary
Ty p i c a l VC P Pe r c e n t a g e s
Zone
0-30
0-40
0-60
0-90
0-180
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Lumens
1118
1862
3353
3621
3621
%Lamp
20.3
33.9
61.0
65.8
65.8
%Fixture
30.9
51.4
92.6
100.0
100.0
10%
30 10
67
60
53
47
41
37
33
29
27
24
22
Height Along
8.5’
10.0’
73
68
80
75
83
79
82
78
85
82
67
59
51
45
39
34
30
27
24
21
20
0%
0
66
58
50
43
37
33
29
25
23
20
18
Height Across
8.5’
10.0’
72
66
80
74
84
79
83
78
87
83
ORDER IN G INFOR M A TION
SAMPLE NUMBER: 2P2GAX-2U1-5/8S33I-UNV-EB81-U
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
HR=Heat
Removal (1)
Width
2=2' Width
P=Paralux Louver
2=2" Louver Depth
Trim Type
G=Grid/Lay-in (Standard)
G=Concealed T/Slot Grid (7)
F=Aluminum Flange Trim (5)
MZ=Modular Trim
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver
with Directional Air Vane (Add V)
Voltage (3)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (4)
Number
of Lamps
2 lamps
Wattage (Length)
U15/8=31W T8 (24")
Louver Color
S=Silver
W=White
Cell Configuration
22=2 Rows of 2, 4 Cell (2' x 2')
23=2 Rows of 3, 6 Cell (2' x 2')
33=3 Rows of 3, 9 Cell (2' x 2')
34=3 Rows of 4, 12 Cell (2' x 2')
44=4 Rows of 4, 16 Cell (2' x 2')
55=5 Rows of 5, 25 Cell (2' x 2')
Louver Finish
I=Semi-Specular/Haze (Low Iridescent)
Standard (Silver Only)
MI=Specular/Mirrored (Low Iridescent)
(Silver Only)
P=Painted (White only)
Option – Aluminum Flange Trim (5)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
Options
GL=Single Element
Fuse
GM=Double Element
Fuse
WTR=White Reveal
Lamps=Lamps Installed
(refer to lamp ordering
options)
Flex=Flex Installed
(Reference Flex ordering information)
EL=Emergency
Installed (6)
(1)
Ballast Type
EB8 =T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
EB8 /PLUS= T8 Electronic Start.
Total Harmonic Distortion < 10%
High Ballast Factor >1.15
No. of Ballast
1 or 2
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
Packaging
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
Options
PAF=Painted After
Fabrication
REP=Riveted
Endplates
ACCESSORIES
EQ-CLIP-U=T-BAR Safety Earthquake Clips(2)
(2)
NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for
(3)
all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies
(4)
(5)
for international markets. Not available when specifying emergencies, voltage must be specific. Specify row
(6)
configuration, type in catalog number when ordering complete fixture. Fixtures equipped with “EL” option may
(7)
require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. Louver is recessed by 5/16"
in Concealed T or Slot Grid T.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to
change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
SH IP P ING D A T A
Catalog No.
2P2GAX-2U1-5/8S33II
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
Wt.
28 lbs.
ADF090416
2015-10-13 15:02:03
Download