NEO-RAY DESCRIPTION The Nimbus II Wall series offers simple design and flexibility without sacrificing performance. Multiple lamp configurations in T8 and T5 high output fluorescent provide maximum flexibility for the architectural environment. Nimbus II creates a comfortable and uniformly balanced environment. All of these elements combined make the Neoray Nimbus II an excellent selection for private offices, open office areas, VDT workspaces, classrooms and corridors. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES A ... Construction Housing is one-piece, die-formed, cold rolled steel, forming a 7" x 2-1/2" architectural profile. Perforated sections are 33% open with .1563" staggered hole pattern and opal diffuser. Standard 4'-0" and 8'-0" luminaire lengths combine for continuous runs. B ... End Caps Standard end caps are precision die-cast aluminum mechanically attached without exposed fasteners. C ... Reflectors Reflector is die-formed, semispecular anodized aluminum. D ... Electrical Luminaires are prewired with quick wire connectors and use UL list Class P, 265ma T8 electronic ballasts. Power factor of 95% with less than 20% THD. Fixtures and electrical components certified to UL and CUL standards. E ... Finish Luminaire housings are standard white using electrostatically applied acrylic powder coat paint. Mounting Fixture mounts directly to existing structure over a 2" x 4" standard electrical box mounted horizontally in the wall. Refer to installation section for details. Nimbus II 701-IW 2T8 A D C END CAP E B WALL-MOUNT SEMI-INDIRECT 2-1/2" [64mm] Light Distribution Indirect - 95.7% Direct - 4.3% 2-1/2" [63mm] 7" [177mm] 7-1/8" [181mm] M O D U L A R R O W C O N F I G U R AT I O N • Standard length sections join easily to create rows. • Sections align with T-grid. • All sections prewired for through-wiring with quick connectors. 5" [127mm] S TA N D A R D L U M I N A I R E L E N G T H S ORDERING INFORMATION S A M P L E N U M B E R : 7 0 1 I W- S P - 2 T 8 - 1 C - 1 - S U - WA - 2 4 701IW Series 701IW =Nimbus II Wall Mount S P Optics Up S=Specular Optics Down P=Perforated 1 2 T8 Number of Lamps (not included) 1=1 Lamp 2=2 Lamps Lamp Type (Length) T8=32W (4' Unit) 1 Number of Circuits 1 1=1 Circuit Wiring 1 C=Standard Circuit D=Dimming E=Emergency/Night Light B=Battery Pack SU-WA Voltage 1 1=120V 2=277V 3=347V U= Universal SU-WA= Surface/Wall Mount Run Length Individual or continuous runs will be configured with 4' and 8' sections only (see sample catalog #) Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. ADN070872 07/20/2007 9:40:15 AM Nimbus II 701-IW PHOTOMETRICS Coefficients of Utilization rc 701IW-SP-2T8 (1) F32T8/TL841 3000 Lumens Candela Effective floor cavity reflectance 80% 70% 20% 50% 70 50 30 10 30% 70 50 30 10 60 55 60 60 60 52 50 48 52 52 52 52 47 45 43 41 36 36 36 31 30 29 22 22 22 19 18 18 09 09 09 08 07 07 03 02 2 3 4 5 49 45 41 38 45 40 35 30 42 36 31 26 39 32 27 23 43 39 35 32 39 34 30 27 36 31 27 23 34 28 24 20 27 24 21 19 26 22 19 16 24 20 17 15 17 15 13 12 16 14 12 10 15 13 11 09 07 06 05 05 06 06 05 04 06 05 04 04 02 02 01 01 6 7 8 9 35 32 29 27 28 25 22 20 23 20 18 16 20 17 15 13 30 27 25 23 24 21 19 17 20 18 15 14 17 15 13 11 17 15 14 12 14 13 11 10 13 11 09 08 10 09 09 08 09 08 07 06 08 07 06 05 04 04 03 03 04 03 03 03 03 03 02 02 01 01 01 01 10 25 18 14 11 03 02 02 01 11 09 07 50 30 10 07 06 05 50 30 10 Efficiency 62.3% Test Report #LSI16234 0% rw RCR 0 1 22 16 12 10 50 30 10 10% Zonal Lumen Summary Luminance Data Zone Lumens %Lamp %Fixture 0-30 0-40 21 34 .72 1.16 1.16 1.87 0-60 0-90 40-90 60-90 60 79 44 19 2.01 2.65 1.48 .64 3.22 4.25 2.38 1.03 90-180 0-180 1789 1868 59.65 62.29 95.75 100.00 Angle in Deg 45 55 0-Deg cd/sm 373 337 45-Deg cd/sm 554 504 90-Deg cd/sm 592 610 65 75 85 125 0 0 488 371 242 577 590 388 0 Angle 0 Along II 28 45° 28 Across 28 5 15 27 26 29 32 30 35 25 35 45 55 23 20 15 11 33 29 29 24 37 36 35 32 65 75 85 90 3 0 0 0 20 12 6 3 27 24 13 7 95 105 115 125 135 16 101 187 266 334 58 323 536 611 569 34 352 518 773 778 145 155 165 175 391 435 464 478 560 579 563 505 658 615 597 516 180 473 473 473 STANDARD BATTERY AND EMERGENCY/NIGHTLIGHT LOCATIONS B/EM 48" [1219mm] B/EM 96" [2438mm] B/EM Power Feed Battery or Night-light Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN070872 07/20/2007 9:40:15 AM