NEO-RAY
DESCRIPTION
The Nimbus II series offers simple design and flexibility without sacrificing
performance. Multiple lamp configurations in T8 and T5 high output
fluorescent provide maximum flexibility for the architectural environment.
In addition, the Nimbus II is modular with suspension points falling on exact
48" increments for ease of installation. Nimbus II creates a comfortable and
uniformly balanced environment. All of these elements combined make the
Nimbus II an excellent selection for large open office areas, VDT
workspaces, classrooms and virtually any open space.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
Housing is one piece die-formed
cold rolled steel, forming a 9" x
2-1/2" architectural profile.
Perforated sections are 33% open
with 5/32" staggered hole pattern
and opal diffuser. Standard 4'-0",
8'-0" and 12'-0" fixture lengths
combine for continuous runs.
C ... Reflectors
Side and center reflectors are
die-formed, highly specular
aluminum.
D ... Electrical
Luminaires are prewired with quick
wire connectors and use UL list
Class P, T5HO program rapid start
universal voltage electronic
ballasts. Power factor of 97% with
less than 10% THD. Fixtures and
electrical components certified to
UL and CUL standards.
Note: Please consult factory,
Fifthlight may not be available in
some configured options.
B ... End Caps
End caps are precision die-cast
aluminum mechanically attached
without exposed fasteners.
A
C
D
END CAP
E
Nimbus II
701-IP
B
3T5HO
9" [229mm]
2-1/2"
[63mm]
SUSPENDED
Semi-Indirect
2-1/2"
[63mm]
9" [229mm]
Light Distribution
5" [127mm]
M O D U L A R R O W C O N F I G U R AT I O N
• Standard length sections join easily to create rows.
• Sections align with T-grid.
• All sections prewired for through-wiring with quick connectors.
Indirect - 94.6%
Direct - 5.4%
S TA N D A R D L U M I N A I R E L E N G T H S
ORDERING INFORMATION
Sample Number: 701IP-SP-3T5HO-1C-277-DC48-T1-48
Series
701IP=Nimbus II
Number of Lamps
3=3 Lamps
Optics Up
S=Specular
Lamp Type
N5=N5 Normal Output
Optics Down
P=Perforated
T5=T5 High Output
Number of Circuits
1=1 Circuit
1
Wiring 1
B=Battery Pack
Voltage 1
120=120V
Power Feed 1
C=Straight Cord
Ceiling Type
T1=1'' T-Bar
C=Standard Circuit
D=Dimming
277=277V
347=347V
K=Curly Cord
P=Rigid Pendant
T9=9/16'' T-Bar
TS=Slotted T-Bar
E=Emergency
T=Nightlight
UNV=Universal
(120V277V)
Suspension Length
ST=Structure
JB=4'' Octagonal
J-Box
Y=Daylight
Suspension
A=Aircraft Cable
2=2 Circuits
(Inboard/Outboard)
P=Rigid Pendant 2
(single stem)
Adjustable Cable
48", 120", 240", 300", or
360" (infinite adjustment along
entire length of cable)
Rigid Pendant
3
12", 15", 18", 21", 24", or 27"
D=Dual Aircraft
Cable OR
Dual Swivel
Rigid Pendant
Notes: 1
Run Length
Individually Mounted
Luminaires may be 4', 8', or 12'
in length
Continuously Mounted
Standard row configurations over
12' consist of 8' and 12' sections
Not all options available. Please consult your Cooper Lighting Representative for availability.
2
Available with 7° or earthquake 45° swivel canopy assembly.
3
Consult factory for custom rigid pendant lengths.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADN041795
09/19/2013 12:29:19 PM
Nimbus II 701-IP
PHOTOMETRICS
Coefficients of Utilization
rc
Effective floor cavity reflectance
80%
70%
20%
50%
30%
10%
0%
Along II
230
45°
230
Across ⊥
230
70
50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
5
15
232
223
228
221
227
218
0
1
90
82
74
68
90
78
68
60
90
75
63
53
90
72
58
48
78
70
64
58
78
67
59
52
78
65
54
47
78
61
51
42
55
48
41
37
55
46
39
33
55
44
36
31
33
29
25
23
33
28
24
21
33
27
23
19
14
12
11
10
14
12
10
09
14
12
10
08
05
04
03
03
25
35
202
172
202
179
205
183
62
57
52
48
53
46
41
37
46
40
34
30
41
34
29
25
53
49
44
41
46
40
36
32
40
35
30
26
36
30
26
22
32
29
26
23
29
25
22
19
26
22
19
16
20
18
16
14
18
16
14
12
16
14
12
10
08
08
07
06
08
07
06
05
07
06
05
05
03
02
02
02
45
55
65
75
132
90
44
17
147
116
89
60
157
136
114
85
44
41
38
33 27 22
30 23 19
27 21 17
05 05 04
05 04 03
05 04 03
01
01
01
85
90
95
105
0
0
102
536
31
21
390
1351
52
35
379
1592
115
125
135
145
1039
1522
1954
2317
2102
2518
2678
2804
2251
2947
3195
3152
155
165
175
180
2597
2788
2885
2876
2936
2942
2878
2876
3097
3048
2879
2876
6
7
8
9
10
38 29 23 19
35 26 21 17
32 24 18 15
21 17 14
19 15 12
17 13 11
13 11 09
12 09 08
11 08 07
Efficiency 93.2%
Zonal Lumen Summary
Test Report
#LSI15723
Angle
0
rw
RCR
2
3
4
5
701IP-3T5
(3) FP54/841/HO
4500 Lumens
Candela
Luminance Data
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
177
288
501
1.31
2.13
3.72
1.41
2.29
3.99
0-90
40-90
60-90
90-180
674
386
173
11904
5.00
2.86
1.28
88.18
5.36
3.07
1.38
94.64
0-180
12579
93.18
100.00
Angle
in Deg
45
0-Deg
cd/sm
1594
45-Deg
cd/sm
1774
90-Deg
cd/sm
1901
55
65
75
85
1342
893
568
0
1732
1823
1755
1249
2045
2205
2036
1583
MOUNTING INFORMATION
S t a nd ar d Jo i n in g – Dua l ai rcra f t cable precisely aligns with suspended t ile cei li ng.
48"
48"
96"
96"
144"
144"
Beginning or end of run
Intermediate
Specifications and Dimensions subject to change without notice.
Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADN041795
09/19/2013 12:29:19 PM
Download