NEO-RAY DESCRIPTION The Nimbus II series offers simple design and flexibility without sacrificing performance. Multiple lamp configurations in T8 and T5 high output fluorescent provide maximum flexibility for the architectural environment. In addition, the Nimbus II is modular with suspension points falling on exact 48" increments for ease of installation. Nimbus II creates a comfortable and uniformly balanced environment. All of these elements combined make the Nimbus II an excellent selection for large open office areas, VDT workspaces, classrooms and virtually any open space. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES A ... Construction Housing is one piece die-formed cold rolled steel, forming a 9" x 2-1/2" architectural profile. Perforated sections are 33% open with 5/32" staggered hole pattern and opal diffuser. Standard 4'-0", 8'-0" and 12'-0" fixture lengths combine for continuous runs. C ... Reflectors Side and center reflectors are die-formed, highly specular aluminum. D ... Electrical Luminaires are prewired with quick wire connectors and use UL list Class P, T5HO program rapid start universal voltage electronic ballasts. Power factor of 97% with less than 10% THD. Fixtures and electrical components certified to UL and CUL standards. Note: Please consult factory, Fifthlight may not be available in some configured options. B ... End Caps End caps are precision die-cast aluminum mechanically attached without exposed fasteners. A C D END CAP E Nimbus II 701-IP B 3T5HO 9" [229mm] 2-1/2" [63mm] SUSPENDED Semi-Indirect 2-1/2" [63mm] 9" [229mm] Light Distribution 5" [127mm] M O D U L A R R O W C O N F I G U R AT I O N • Standard length sections join easily to create rows. • Sections align with T-grid. • All sections prewired for through-wiring with quick connectors. Indirect - 94.6% Direct - 5.4% S TA N D A R D L U M I N A I R E L E N G T H S ORDERING INFORMATION Sample Number: 701IP-SP-3T5HO-1C-277-DC48-T1-48 Series 701IP=Nimbus II Number of Lamps 3=3 Lamps Optics Up S=Specular Lamp Type N5=N5 Normal Output Optics Down P=Perforated T5=T5 High Output Number of Circuits 1=1 Circuit 1 Wiring 1 B=Battery Pack Voltage 1 120=120V Power Feed 1 C=Straight Cord Ceiling Type T1=1'' T-Bar C=Standard Circuit D=Dimming 277=277V 347=347V K=Curly Cord P=Rigid Pendant T9=9/16'' T-Bar TS=Slotted T-Bar E=Emergency T=Nightlight UNV=Universal (120V277V) Suspension Length ST=Structure JB=4'' Octagonal J-Box Y=Daylight Suspension A=Aircraft Cable 2=2 Circuits (Inboard/Outboard) P=Rigid Pendant 2 (single stem) Adjustable Cable 48", 120", 240", 300", or 360" (infinite adjustment along entire length of cable) Rigid Pendant 3 12", 15", 18", 21", 24", or 27" D=Dual Aircraft Cable OR Dual Swivel Rigid Pendant Notes: 1 Run Length Individually Mounted Luminaires may be 4', 8', or 12' in length Continuously Mounted Standard row configurations over 12' consist of 8' and 12' sections Not all options available. Please consult your Cooper Lighting Representative for availability. 2 Available with 7° or earthquake 45° swivel canopy assembly. 3 Consult factory for custom rigid pendant lengths. Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. ADN041795 09/19/2013 12:29:19 PM Nimbus II 701-IP PHOTOMETRICS Coefficients of Utilization rc Effective floor cavity reflectance 80% 70% 20% 50% 30% 10% 0% Along II 230 45° 230 Across ⊥ 230 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 5 15 232 223 228 221 227 218 0 1 90 82 74 68 90 78 68 60 90 75 63 53 90 72 58 48 78 70 64 58 78 67 59 52 78 65 54 47 78 61 51 42 55 48 41 37 55 46 39 33 55 44 36 31 33 29 25 23 33 28 24 21 33 27 23 19 14 12 11 10 14 12 10 09 14 12 10 08 05 04 03 03 25 35 202 172 202 179 205 183 62 57 52 48 53 46 41 37 46 40 34 30 41 34 29 25 53 49 44 41 46 40 36 32 40 35 30 26 36 30 26 22 32 29 26 23 29 25 22 19 26 22 19 16 20 18 16 14 18 16 14 12 16 14 12 10 08 08 07 06 08 07 06 05 07 06 05 05 03 02 02 02 45 55 65 75 132 90 44 17 147 116 89 60 157 136 114 85 44 41 38 33 27 22 30 23 19 27 21 17 05 05 04 05 04 03 05 04 03 01 01 01 85 90 95 105 0 0 102 536 31 21 390 1351 52 35 379 1592 115 125 135 145 1039 1522 1954 2317 2102 2518 2678 2804 2251 2947 3195 3152 155 165 175 180 2597 2788 2885 2876 2936 2942 2878 2876 3097 3048 2879 2876 6 7 8 9 10 38 29 23 19 35 26 21 17 32 24 18 15 21 17 14 19 15 12 17 13 11 13 11 09 12 09 08 11 08 07 Efficiency 93.2% Zonal Lumen Summary Test Report #LSI15723 Angle 0 rw RCR 2 3 4 5 701IP-3T5 (3) FP54/841/HO 4500 Lumens Candela Luminance Data Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 177 288 501 1.31 2.13 3.72 1.41 2.29 3.99 0-90 40-90 60-90 90-180 674 386 173 11904 5.00 2.86 1.28 88.18 5.36 3.07 1.38 94.64 0-180 12579 93.18 100.00 Angle in Deg 45 0-Deg cd/sm 1594 45-Deg cd/sm 1774 90-Deg cd/sm 1901 55 65 75 85 1342 893 568 0 1732 1823 1755 1249 2045 2205 2036 1583 MOUNTING INFORMATION S t a nd ar d Jo i n in g – Dua l ai rcra f t cable precisely aligns with suspended t ile cei li ng. 48" 48" 96" 96" 144" 144" Beginning or end of run Intermediate Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN041795 09/19/2013 12:29:19 PM