NEO-RAY DESCRIPTION The Nimbus II Wall series offers simple design and flexibility without sacrificing performance. Multiple lamp configurations in T8 and T5 high output fluorescent provide maximum flexibility for the architectural environment. Nimbus II creates a comfortable and uniformly balanced environment. All of these elements combined make the Neoray Nimbus II an excellent selection for private offices, open office areas, VDT workspaces, classrooms and corridors. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES A ... Construction Housing is one-piece, die-formed, cold rolled steel, forming a 7" x 2-1/2" architectural profile. Perforated sections are 33% open with .1563" staggered hole pattern and opal diffuser. Standard 4'-0" and 8'-0" luminaire lengths combine for continuous runs. B ... End Caps Standard end caps are precision die-cast aluminum mechanically attached without exposed fasteners. C ... Reflectors Reflector is die-formed, semispecular anodized aluminum. D ... Electrical Luminaires are prewired with quick wire connectors and use UL list Class P, 265ma T8 electronic ballasts. Power factor of 95% with less than 20% THD. Fixtures and electrical components certified to UL and CUL standards. Note: Please consult factory, Fifthlight may not be available in some configured options. E ... Finish Luminaire housings are standard white using electrostatically applied acrylic powder coat paint. Mounting Fixture mounts directly to existing structure over a 2" x 4" standard electrical box mounted horizontally in the wall. Refer to installation section for details. Nimbus II 701-IW 1T8 A D C END CAP E WALL-MOUNT B SEMI-INDIRECT Light Distribution 2-1/2" [64mm] Indirect - 95.7% Direct -4.3% 2-1/2" [63mm] 7" [177mm] 7-1/8" [181mm] M O D U L A R R O W C O N F I G U R AT I O N • Standard length sections join easily to create rows. • Sections align with T-grid. • All sections prewired for through-wiring with quick connectors. 5" [127mm] S TA N D A R D L U M I N A I R E L E N G T H S ORDERING INFORMATION Sample Number: 701IW-SP-1T8-1C-1-SU-WA-24 Series 701IW=Nimbus II Optics Up S=Specular Number of Lamps (Not included) Lamp Type T8=T8 Normal Output 1=1 Lamp Optics Down P=Perforated Number of Circuits 1=1 Circuit 1 Wiring 1 B=Battery Pack Voltage 1 120=120V C=Standard Circuit D=Dimming 277=277V 347=347V E=Emergency T=Nightlight UNV=Universal (120V-277V) Y=Daylight Notes: 1 Not all options available. Please consult your Cooper Lighting Representative for availability. Individually Mounted Luminaires may be 4' or 8' in length Continuously Mounted Standard row configurations over 8' consist of 4' and 8' sections Suspension SU-WA=Surface/Wall Mount Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. Run Length ADN041843 09/19/2013 4:44:55 PM Nimbus II 701-IW PHOTOMETRICS Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 701IW-SP-1T8 (1) F32T8/TL841 3000 Lumens 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 20% 50% 30% 10% 0% 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 60 55 49 45 60 52 45 40 60 50 42 36 60 48 39 32 52 47 43 39 52 45 39 34 52 43 36 31 52 41 34 28 36 31 27 24 36 30 26 22 36 29 24 20 22 19 17 15 22 18 16 14 22 18 15 13 09 08 07 06 09 07 06 06 09 07 06 05 03 02 02 02 41 38 35 32 35 30 28 25 31 26 23 20 27 23 20 17 35 32 30 27 30 27 24 21 27 23 20 18 24 20 17 15 21 19 17 15 19 16 14 13 17 15 13 11 13 12 10 09 12 10 09 08 11 09 08 07 05 05 04 04 05 04 04 03 04 04 03 03 01 01 01 01 29 27 25 22 18 15 20 16 13 18 14 11 03 03 02 03 03 02 03 02 02 01 01 01 25 19 15 13 23 17 14 11 22 16 12 10 14 11 09 12 10 08 11 09 07 09 07 06 08 06 05 07 06 05 Efficiency 62.3% Test Report #LSI16234 Zonal Lumen Summary Luminance Data Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 21 34 60 .72 1.16 2.01 1.16 1.87 3.22 0-90 40-90 60-90 90-180 79 44 19 1789 2.65 1.48 .64 59.65 4.25 2.38 1.03 95.75 0-180 1868 62.29 100.00 Angle in Deg 45 0-Deg cd/sm 373 45-Deg cd/sm 554 90-Deg cd/sm 592 55 65 75 85 337 125 0 0 504 488 371 242 610 577 590 388 Angle 0 Along II 28 45° 28 Across ⊥ 28 5 15 25 35 27 26 23 20 29 32 33 29 30 35 37 36 45 55 65 75 15 11 3 0 29 24 20 12 35 32 27 24 85 90 95 105 0 0 16 101 6 3 58 323 13 7 34 352 115 125 135 145 187 266 334 391 536 611 569 560 518 773 778 658 155 165 175 180 435 464 478 473 579 563 505 473 615 597 516 473 STANDARD BATTERY AND EMERGENCY/NIGHTLIGHT LOCATIONS B/EM 48" [1219mm] B/EM 96" [2438mm] B/EM Power Feed Battery or Night-light Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN041843 09/19/2013 4:44:55 PM