Catalog # Type

advertisement
NEO-RAY
DESCRIPTION
The Nimbus II series offers simple design and flexibility without sacrificing
performance. Multiple lamp configurations in T8 and T5 high output
fluorescent provide maximum flexibility for the architectural environment.
In addition, the Nimbus II is modular with suspension points falling on exact
48" increments for ease of installation. Nimbus II creates a comfortable and
uniformly balanced environment. All of these elements combined make the
Nimbus II an excellent selection for large open office areas, VDT
workspaces, classrooms and virtually any open space.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
Housing is one piece die-formed
cold rolled steel, forming a 9" x
2-1/2" architectural profile.
Perforated sections are 33% open
with 5/32" staggered hole pattern
and opal diffuser. Standard 4'-0",
8'-0" and 12'-0" fixture lengths
combine for continuous runs.
C ... Reflectors
Die-formed, highly specular
aluminum.
D ... Electrical
Luminaires are prewired with quick
wire connectors and use UL list
Class P, T5HO program rapid start
universal voltage electronic
ballasts. Power factor of 97% with
less than 10% THD. Fixtures and
electrical components certified to
UL and CUL standards.
Note: Please consult factory,
Fifthlight may not be available in
some configured options.
B ... End Caps
End caps are precision die-cast
aluminum mechanically attached
without exposed fasteners.
A
C
D
END CAP
E
Nimbus II
701- IP
B
9" [229mm]
2T5HO
2-1/2"
[63mm]
SUSPENDED
2-1/2"
[63mm]
SEMI-INDIRECT
5" [127mm]
9" [229mm]
Light Distribution
Indirect - 93.2%
Direct - 6.8%
M O D U L A R R O W C O N F I G U R AT I O N
• Standard length sections join easily to create rows.
• Sections align with T-grid.
• All sections prewired for through-wiring with quick connectors.
S TA N D A R D L U M I N A I R E L E N G T H S
ORDERING INFORMATION
Sample Number: 701IP-SP-2T5HO-1C-277-DC48-T1-48
Series
701IP=Nimbus II
Number of Lamps
2=2 Lamps
Optics Up
S=Specular
Lamp Type
N5=N5 Normal Output
Optics Down
P=Perforated
T5=T5 High Output
Number of Circuits
1=1 Circuit
1
Wiring 1
B=Battery Pack
Voltage 1
120=120V
Power Feed 1
C=Straight Cord
Ceiling Type
T1=1'' T-Bar
C=Standard Circuit
D=Dimming
277=277V
347=347V
K=Curly Cord
P=Rigid Pendant
T9=9/16'' T-Bar
TS=Slotted T-Bar
E=Emergency
T=Nightlight
UNV=Universal
(120V277V)
Suspension Length
ST=Structure
JB=4'' Octagonal
J-Box
Y=Daylight
2=2 Circuits (Side by Side)
Suspension
A=Aircraft Cable
Pendant 2
P=Rigid
(single stem)
Adjustable Cable
48", 120", 240", 300", or
360" (infinite adjustment along
entire length of cable)
Rigid Pendant
3
12", 15", 18", 21", 24", or 27"
D=Dual Aircraft
Cable OR
Dual Swivel
Rigid Pendant
Notes: 1
Run Length
Individually Mounted
Luminaires may be 4', 8', or 12'
in length
Continuously Mounted
Standard row configurations over
12' consist of 8' and 12' sections
Not all options available. Please consult your Cooper Lighting Representative for availability.
2
Available with 7° or earthquake 45° swivel canopy assembly.
3
Consult factory for custom rigid pendant lengths.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADN041794
09/19/2013 12:08:44 PM
Nimbus II 701- IP
PHOTOMETRICS
Coefficients of Utilization
rc
Effective floor cavity reflectance
80%
70%
20%
50%
30%
10%
0%
Along II
187
45°
187
Across ⊥
187
70
50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
5
15
187
174
187
179
185
177
0
1
87
79
72
66
87
76
66
58
87
72
61
52
87
69
56
47
75
68
62
57
75
65
57
50
75
63
53
45
75
60
49
41
53
46
40
36
53
45
38
33
53
43
36
30
33
29
25
22
33
28
24
21
33
27
23
19
15
13
11
10
15
13
11
09
15
12
10
09
06
05
04
04
25
35
157
136
165
143
168
146
60
55
50
46
51
44
40
36
44
38
33
29
39
33
29
25
51
47
43
40
44
39
35
31
39
34
29
26
35
29
25
22
32
28
25
22
28
24
21
19
25
21
18
16
20
18
16
14
18
15
14
12
16
14
12
10
09
08
07
06
08
07
06
05
07
06
06
05
03
03
02
02
45
55
65
75
109
74
42
16
118
94
71
51
126
111
88
70
42
39
37
32 26 21
29 23 19
26 20 16
06 05 04
05 04 04
05 04 03
02
01
01
85
90
95
105
0
0
60
322
26
15
327
904
44
30
297
899
115
125
135
145
631
932
1199
1423
1402
1561
1641
1782
1616
1918
1968
1921
155
165
175
180
1597
1716
1777
1773
1847
1816
1774
1773
1957
1883
1759
1773
6
7
8
9
10
37 28 23 19
34 25 20 16
32 23 18 14
20 16 14
18 15 12
17 13 11
13 11 09
12 09 08
11 08 07
Efficiency 89.9%
Zonal Lumen Summary
Test Report
#LSI15721
Angle
0
rw
RCR
2
3
4
5
701IP-2T5
(2) FP54/841/HO
4500 Lumens
Candela
Luminance Data
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
142
231
404
1.59
2.57
4.49
1.76
2.86
4.99
0-90
40-90
60-90
90-180
548
316
144
7543
6.09
3.52
1.60
83.82
6.78
3.92
1.78
93.22
0-180
8091
89.91
100.00
Angle
in Deg
45
0-Deg
cd/sm
1321
45-Deg
cd/sm
1427
90-Deg
cd/sm
1532
55
65
75
85
1097
843
521
0
1411
1465
1496
1040
1665
1716
1675
1343
MOUNTING INFORMATION
S t a nd ar d Jo i n in g – Dua l ai rcra f t cable precisely aligns with suspended t ile cei li ng.
48"
48"
96"
96"
144"
144"
Beginning or end of run
Intermediate
Specifications and Dimensions subject to change without notice.
Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADN041794
09/19/2013 12:08:44 PM
Download